10 Block SPECIAL FUNCTION
Device Functions Proline Promag 55
132
Hauser
10.1.2
Function group ACQUISITION
SPECIAL FUNCTION
H
⇒
ADV. DIAGNOSTICS
HEA
⇒
CONFIGURATION
750
⇓
ACQUISITION
751
Function description
SPECIAL FUNCTION
➞
ADV. DIAGNOSTICS
➞
ACQUISITION
ACQUISITION MODE
(7510)
In this function, you define whether the diagnostic parameters are acquired periodically
by the measuring device or manually by the user.
Options:
OFF
PERIODICAL
SINGLE SHOT
Factory setting:
OFF
ACQUISITION PERIOD
(7511)
!
Note!
This function is not available unless the "PERIODICAL" setting was selected in the
ACQUISITION MODE function (7510).
In this function, a time interval is specified that is used to acquire and record the affected
diagnostic parameters periodically. This function is active as soon as the input is
confirmed with the
F
key.
User input:
10 to 10 080 min
Factory setting:
60 min
!
Note!
A defined reference condition must be present before the diagnostic parameters are
measured
→
see Function SELECT REFERENCE CONDITION (7502).
DO ACQUISITION
(7512)
!
Note!
This function is not available unless the "SINGLE SHOT" setting was selected in the
ACQUISITION MODE function (7510).
This function can be used to start the test measurements of diagnostic parameters
manually, e.g. sporadically depending on the process conditions.
Options:
CANCEL
START
Factory setting:
CANCEL
!
Note!
A defined reference condition must be present before the diagnostic parameters are
acquired
→
see Function SELECT REFERENCE CONDITION (7502).
RESET HISTORY
(7513)
All previously saved diagnostic parameter values can be deleted with this function (=
parameters of the COATING E1, COATING E2, ELECTRODE POTENTIAL 1,
ELECTRODE POTENTIAL 2 and VOLUME FLOW function groups).
Options:
NO
YES
Factory setting:
NO
Содержание Proline Promag 55
Страница 2: ...Device Functions Proline Promag 55 2 Endress Hauser ...
Страница 5: ...Device Functions Proline Promag 55 Contents Endress Hauser 5 ...
Страница 164: ...14 Index Device Functions Proline Promag 55 164 Endress Hauser ...
Страница 166: ...www endress com worldwide BA120D 06 en 10 09 71104957 FM SGML6 0 ...