background image

 

 

HM-USB-ISO User Manual 

 

 
 
 

MAN-1008 19/7/2012 v2 

Designed and Produced under 

Page 7 of 8

 

ISO 9001:2008 Certification 

 

Warranty 

The USB HART Modem (HM-USB-ISO) is warranted for 1 year for materials and workmanship. Contact 
HART Expert Ltd (UK) or ProComSol Ltd (USA) if having trouble. In the unlikely event that you will need 
to return a modem for a repair/replacement, an RMA (Return Material Authorization) number from 
HART Expert or ProComSol is required for all returned items. 
 
 

Specifications: 

 

Enclosure 

Material 

 

 

High strength ABS Plastic 

Dimensions 

 

 

70mm x 51mm x 20mm 

Total Unit Weight 

 

85 g 

 
Cables 

HART Cable Length 

 

1.2 m 

HART Cable Connectors  

Mini-Grabber 

USB Cable Length 

 

0.5 m 

USB Cable Connector   

USB Type A 

 
HART 

Interface 

 

 

Capacitive and transformer coupling 

Output   

 

 

600 mVpp 

Leakage 

 

 

< 10 uA 

Isolation Voltage 

 

1500 Vdc 

Connections 

 

 

Across loop resistor or HART field device 

Specifications   

 

HART 4, HART 5, HART 6, HART 7, 

 

 

 

 

HART Physical Layer Spec HCF_SPEC-54 

HART Foundation 

 

Registration Number L2-06-1000-070 

 
Computer 

Operating System 

 

Windows 32 and 64 bit versions: NT, 2000, XP, Vista, 7, 8, 8.1, and 10 

 
USB 

Specifications   

 

USB 1.1, USB 2.0, backward compatible with USB 3.0 and SS USB 

Power   

 

 

USB port provides power to unit 

Current Draw   

 

20mA 

 
Environmental 

Operating Temperature  

0 deg.C to 50 deg.C 

Storage Temperature   

-40 deg.C to 85 deg.C 

Humidity 

 

 

0% to 99% (non-condensing) 

 

Compliances 

CE Certification  

 

EN 61326 (EMC)

 

 

Содержание USB HART Modem

Страница 1: ...Contents Introduction 1 Installation 2 Step 1 Install Software Drivers 2 Step 2 Connect the USB HART Modem to your PC 2 Step 3 COM Port Number Assignment 3 Step 4 Connect to HART device network 3 Ste...

Страница 2: ...r has completed installation the program HM Test will open ready for you to latter test your USB HART Modem connection If you are not using the CD HM Test can be downloaded from http www hart expert c...

Страница 3: ...you leave it at the automatically assigned port number unless you know what you are doing and have a reason to change it Step 4 Connect to HART device network The modem can be connected in one of two...

Страница 4: ...ed to try our HART Communicator software free for 10 days please see http www hart expert co uk online shop hart communicator software free 10 day trial windows pcs Troubleshooting A Windows PC rememb...

Страница 5: ...nverter or USB High Speed Serial Converter or USB Serial port Right click on any matching entries and select Uninstall g If it exists expand Other devices h Right click on any entries called USB Seria...

Страница 6: ...OK q Under Model select USB Serial Port and press Next r Windows will now install the USB Serial Port driver Depending on your Windows settings you may be notified that the driver is not Windows Micr...

Страница 7: ...le Length 1 2 m HART Cable Connectors Mini Grabber USB Cable Length 0 5 m USB Cable Connector USB Type A HART Interface Capacitive and transformer coupling Output 600 mVpp Leakage 10 uA Isolation Volt...

Страница 8: ...pert co uk Designed and Produced by ProComSol Ltd www procomsol com HART Expert Ltd 31 Kingfisher Way Romsey Hampshire SO51 7RY UK Phone 44 0 7966 233639 Email info hart expert co uk Web www hart expe...

Отзывы: