background image

                                                                                                     i-vent

 

 
 

 
 

 
 
 

 
 

 
 

 
 
 

 
 

 
 

 
 
 

VEC8675WP10_NZ       

Controller 

 
                                                                                                                                                              1 

 

                                                                                                      i-vent

 

 
 

 
 

 
 

 
 
 

 
 

 
 

 
 
 

 
 

 
 

 
 
 

                                                                                                                                                              3 
 

                                                                                                      i-vent

 

 
 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 
 

 
 

                                                                                                                                                              5 
 

 

                                                                                                      i-vent

 

 
 

 
 

 
 
 

 
 

 
 

 
 
 

 
 

 
 

 
 
 

 
 

                                                                                                                                                             7 

                                                                                                      i-vent

 

 
 

 
 

 
 
 

 
 

 
 

 
 
 

 
 

 
 

 
 
 

                                                                                                                                                               
 

 
                                                                                                                                                              2 

 

                                                                                                      i-vent

 

 
 

 
 

 
 

 
 
 

 
 

 
 

 
 
 

 
 

 
 

 
                                                                                                                                                               
 

                                                                                                                                                             4 
 

                                                                                                      i-vent

 

 
 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 
 

 
 

                                                                                                                                                              6 
 

 

                                                                                                      i-vent

 

 
 

 
 

 
 
 

 
 

 
 

 
 
 

 
 

 
 

 
 
 

                                                                                                                                                               
 

                                                                                                                                                              8 
 

Operating 

Instructions 

 

Contents 

I. Features  

II. Get To Know Your Controller 

1. Appearance 
2. Display Information  
3. i-vent System Applications 

III Operating Instructions 

1. Power On/Off 

2. Auto Setting 
3. Manual Fan Speed Setting 

4. View Room Temperature 
5. Adjustment 
6. Outside Air Setting 

7. Filter 
8. Others 

IV. Tips 

  

3. i-vent System Applications  

Standard 

The standard i-vent system circulates dry 
filtered air from the roof space into the 

home. In automatic mode the i-vent 
controller adjusts the fan speed based on 
the roof space temperature, switching it 

off if it gets too hot. Manual fan speed 
control can be selected if required.  

 

Outside Air Option 

If the i-vent system has the Outside Air 
option you may choose to draw in outside 
air automatically when the roof space air 

is too hot. This is ideal for summer. You 
may also choose to operate the i-vent 

controller in manual fan speed mode with 
the outside air flowing continuously.  

III. Operating Instructions 

1. Power On/Off 

Tap  on the touch buttons to power 
On/Off the i-vent controller.  

 

 

2. Auto Setting 

Keep tapping 

 or 

 until 

Auto

 is 

displayed. 

 

Auto is the best choice for optimum 
ventilation and comfort.  

 

When   is displayed the Outside Air mode 
is on.  

 
When 

is displayed, air is flowing from 

the outside. In Auto mode, air will only flow 
from the outside when the roof space air is 

too hot.  
 

The display example below shows Outside 
Air mode is on and air is flowing. 

 

 
To disable Outside Air mode tap 

.  

 

8. Others 

   One or more of the touch buttons are                  
locked.  

 Installer Setup Mode 
 Installer Test Mode 

 
See the Installation Guide for more details. 

I. Features 

•Large LCD display with white 

backlight 

•Capacitive Touch Buttons

 

•Supports standard and outside air 

ventilation systems 

•Auto or manual fan speed cont

rol 

•Optional keypad lock 

 

•Adjustable fan speed temperature set 

points 

 

II. Get to Know Your Controller 

 

1. Appearance 

 

         

2. Display Information  

 

 
1. Roof Space Temperature 

2. Outside Air Mode On (optional) 
3. Touch Button Lock (optional) 

4. Outside Air Flowing 
5. Fan On 
6. Manual Fan Speed Bar Graph 

7. Auto Fan Speed  
8. System Off Indicator 

9. Installer Test 
10. Installer Setup 

3. Manual Fan Speed Setting 

Manual fan speeds can be selected, Low, 
Medium or High. Manual speeds are 
represented by 3 bars.  

 
Keep tapping 

 or 

 until the desired 

speed is

 

displayed.  

 

 

 High speed 

 Medium speed  

 Low speed 

 

Auto speed, no bars 

 
 

 
         

6. Outside Air Setting (Option) 

This section applies if the Outside Air 
option has been installed.  

 
In Auto mode when the roof space air is 
too hot air will be drawn from the outside. 

Once the roof space air cools air will be 
drawn from the roof space.  

 
In Manual Fan Speed mode air will be 

drawn from the outside continuously.  
 
To enable Outside Air mode tap 

.  

 

 

IV Tips 

 

This symbol is displayed 

while the fan is running. If 

it is not displayed the fan 

is off. The roof space air is 

either too hot or too cold. 

Seasonal 

Adjustment  

Seasonal adjustment is 

not required. If you do 

make an adjustment 

(Section III 5.), return 

Index 2 setting to 0.0 

when conditions change.  

Outside Air 

If you want to check if you 

have this feature, look for

 in the display top right 

corner. If it is not there tap

. If   does not appear 

you do not have Outside 

Air mode. 

Temp. Set 

Point 

The i-vent system 

provides maximum 

ventilation based on the 

roof space air temp. User 

operation is simplified by 

not incorporating a 

thermostat type set point.  

 
 

         

Maximum 

Ventilation 

If you need maximum 

ventilation for any reason, set 

the i-vent controller to 

manual. Keep tapping 

 or 

 until three black bars are 

displayed.  

Filter 

Change 

To maintain the warranty the 

filter must be changed every 

12 months. Failure to change 

the filter will lead to 

decreased performance.  

Buttons 

Do Not 

Work 

Check if the touch button lock 
symbol is displayed. See 

the Installation Guide.  

 

Two bars instead of a 

temperature reading mean 

the sensor has failed. Contact 

Harrisons. The fan will still 

run in manual mode.  

Additional 

Support 

www.harrisonsenergy.co.nz 

 

 

 

 

4. View Room Temperature 

Normally the roof space temperature is 
displayed. Room temperature can be 
viewed if required.  

 
Tap   once to view the room temperature.  

 

 
Tap   twice to return to the home screen. 
 

 
 

 

 
         

5. Adjustment 

The i-vent controller is factory set for 
optimum ventilation and comfort control. 

There is an adjustment if required. The 
adjustment changes the fan speed 
temperature set points by up to + or 

 

5°C.  
 

For example, if you are finding the 
ventilation too cold then you can adjust 

the setting from 0 to 5. Doing this will 
reduce the fan speed at lower 
temperatures and keep the fan running 

faster at higher temperatures.  
 

You can also make the home cooler by 
adjusting the setting between -5 to 0.  

 
0 is the default setting. -5 is the coolest 
setting and 5 is the warmest setting.

 

         

Tap   

twice

 to access the adjustment. 

Look for 2 in the top right corner of the 

display. 
 

Tap 

 or 

 to adjust the setting 

between -5.0 and 5.0. 

 

 

 

This adjustment alters the fan speed at 
temperature extremes. The i-vent system 

cannot heat or cool the air drawn in from 
the roof space or outdoors. Use the home 

heating or air conditioning system to 
control the temperature in the home. 

 

7. Filter 

The i-vent system filters the air before it 
enters the home. You will receive a 
reminder to change your filter every 12 

months from Harrisons.  
 

To maintain the i-vent system 10 year 
warranty the filter must be replaced every 

12 months. 

Отзывы: