If the type is set to
Off
, the corresponding function block and external connector are
disabled.
The type can be set to
Copy
on even numbered functions blocks where the preceding
function block type is set to
Mux
. In this case, the corresponding even numbered external
connector will deliver a copy of the output of the preceding odd numbered
Mux
function
block output.
Demux PID Map
The PID map makes it possible to split multiple program streams into a maximum of 240
programs Each program is remapped according to the PID Table shown in the UI. The
default setting for each PID is
-1.
Default PIDs are based on offsets from a base PID of 48. They are:
PMT
: base + 0 (48)
Video
: base + 1 (49)
PCR
: base + 2 (50)
8
Audios
: base + 3 to base + 10 (51 - 58)
2
Data
: base + 11 and base + 12 (59, 60)
ECM
: base + 14 (62)
IP LANs
Primary and Secondary Data IP LANs
The Secondary Data IP LAN settings provided redundancy for the Primary settings. The
backup functions provided by the Secondary Data IP LANs require the installation of a video
IP submodule on the Selenio frame controller. When making settings in the IP LAN table,
ensure that you click the
Apply
button to save your settings.
In a frame with a second controller (with the data Ethernet switch daughter card) the
MDX module can receive and transmit on redundant primary and secondary IP data
links.
On each physical link, IP interfaces can be configured for untagged network traffic (Vlan
ID = 0) and tagged virtual LAN network traffic (Vlan ID 1 to 4094).
VLAN ID
This parameter sets the entry's VLAN identifier.
A value of 0 indicates that the interface is for untagged network traffic.
A value from 1 to 4094 indicates that the interface is for tagged virtual LAN traffic.