QSEE6800
+
H Installation and Operation Manual
39
Chapter 3: Card-Edge and Parameter Operation
QSEE6800
+
H SDI Embedded Audio Alarms
lists QSEE6800
+
H’s embedded audio alarms. These alarms
apply to audio that is embedded in either an HD or SD video stream.
Note that alarm names that contain numbers in parentheses indicate a
series of alarms that share the same description and alarm option default
settings.
Table 3-9.
SDI Embedded Audio Alarms for QSEE6800
+
H
Alarm Name
Alarm
Description
Alarm Option Default Settings
Enable/
Disable Priority
Trigger
(sec)
Clear
(sec)
SDI Embedded Ch (01 to 16) peak
Detects that the peak
audio level meets or
exceeds the limit set
in the
parameter
Enabled
1
30.0
2.0
SDI Embedded Ch (01 to 16) Loss
of Sound
Detects that the audio
amplitude has fallen
below the limit set in
the
parameter
Enabled
1
30.0
2.0
SDI Embedded Ch (01 to 16) Vbit
Set
Detects a set V-Bit in
the embedded audio
source
Enabled
1
1.0
2.0
SDI Embedded Ch (01 to 16) Low
Audio
Detects that the peak
audio sample has
stayed below the level
set in the
parameter
Enabled
1
30.0
2.0
SDI Embedded Ch (01 to 16)
Missing
Reports if the SDI
embedded audio
channel is missing
Enabled
1
1.0
2.0
SDI Embedded Audio Group (1 to
4) Missing
Reports that the audio
in the specified group
is not present
Enabled
1
1.0
2.0