WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 6 Troubleshooting
•
Strike 1 - When any of the above fault conditions is met, the transmitter output is
muted (DAC_APC_REF is brought to zero) for 3 seconds (6 seconds for transmitters
with a Single Phase power supply). At the end of the 3 (or 6) seconds the transmitter
power is slowly ramped back up and a 10 second timer is started.
•
Strike 2 - If another fault is detected before the 10 seconds is up, the transmitter will
again mute for 3 (or 6) seconds, start the 10 second timer again and slowly ramp the
power up again.
•
Strike 3 - A third fault detected within this 10 seconds will cause the transmitter to be
muted until the operator gives the transmitter an ON command (High or Low),
locally or by remote. If the cause of the fault is still present, the transmitter will sim-
ply repeat the 3 strikes and mute again.
NOTE:
If no faults occur during either of the 10 second time periods, then the strike
counter is reset and will allow 3 more strikes before muting the transmitter.
The slow ramp up in power after a strike should allow the foldback controls to limit the
transmitter power output before the fault thresholds are reached again. The slow power
ramps are designed to allow the transmitter to operate at the maximum possible power
level without over-dissipating the isolation resistors or exposing the transmitter to
excessive reflected power. This would mean that there would be a fault in the log but it
would be inactive and the transmitter would be in a foldback condition.
6.6
Diagnostics Display Menu Tree
The most important documentation concerning the Diagnostics Display is the
“Diagnostics Display Menu Tree” located in the schematic drawing package. This
shows the complete Diagnostics Display menu structure. The menus flow from the
Main Menu at the left (on each sheet) up to 6 layers deep to the right. Due to the number
of menu screens, the drawing is divided by main menu items into 3 drawings.
•
Page 1 is Status
•
Page 2 is Metering and Faults
•
Page 3 is Configuration, Test and Software Revision
It greatly simplifies the display by letting you see the entire tree with all of the screens,
guiding you to the screen you want. The only thing missing is the 6 control buttons,
HOME and BACK on the left side of the display and ABCD to the right. To avoid
confusion, every line from one screen to the next is labeled A, B, C or D where it leaves
a screen, to correspond with the keypress required on the actual display. The function
and use of the buttons is very straight forward. However, an explanation is given in
Section III, Operation, for these and all other front panel transmitter controls.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...