9/15/06
888-2586-001
5-21
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignment
Platinum Z16HD+
Figure 5-9 Reflected power CAL Screen
[HOME, MORE, CONFIGURATION, C, D]
STEP 11
Shut the transmitter off and return the Reflected Power Directional
Coupler back to its normal position.
STEP 12
Press [HOME, MORE, CONFIGURATION, B, A, D, D]. This takes you
to the VSWR Foldback Set screen. Set the VSWR FOLDBACK to 1.30
and press [BACK] to save the setting.
STEP 13
Turn the transmitter back on and press the RAISE button on the front
panel until you have 100% or desired TPO.
STEP 14
It is recommended that the REFLECT FACTOR Value be noted for
future reference since it may have changed from the reading in the
factory test data, see Figure 5-7.
Reflected power calibration is now complete.