5-18
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 5 Maintenance and Alignment
press the [BACK] key to the left of the display to calibrate the FWD
power and save the new information. The display will flash
“Calibration Done” very quickly at the bottom of the Diagnostics
Display. The external meter and the FWD PWR reading on the
transmitter should now agree.
STEP 14
Return to the 100% TPO SET screen [HOME, MORE,
CONFIGURATION, B, B], then choose the desired modulation format,
and change the level to match your TPO. Press [BACK] to save the
changes. The FWD PWR meter should read 100% (or your TPO in kW
depending on the setting).
STEP 15
Set the MAX HIGH back to the setting noted in Step 3 or to set a new
MAX HIGH go to “Setting Maximum Power Limits” earlier in this
section.
STEP 16
It is recommended that the following “Cal Values” be noted for future
reference since they may have changed from those noted on the factory
test data sheet: [HOME, MORE, CONFIGURATION, C, A]
•
FORWARD FACTOR
•
CAL FREQUENCY
•
CAL APC FACTOR
Forward power calibration is now complete.
5.13 Reflected Power Calibration
Reflected power calibration must be performed upon replacement of the Life Support or
Master Controller boards, or the Directional Coupler. To correctly re-calibrate your
transmitter follow the procedure below.
It is recommended that the transmitter be calibrated using the desired TPO for your
primary modulation format (FM, HD, FM+HD, or SLC).
This procedure can be done using the forward power reading on the transmitter. If the
forward power also needs to be calibrated, perform the Forward Power Calibration first.
Otherwise, an external meter will have to be used.
STEP 1
Press the HIGH ON button and then quickly press and hold the LOWER
button for 10 seconds. This will turn the transmitter on at zero power
output. Verify the transmitter forward power is zero.
STEP 2
Shut the transmitter off. Turn R128 on the Life Support Board maximum
CCW. This reduces the VSWR sensitivity to minimum.
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...