Section 4 Overall System Theory
Platinum Z16HD+
1.
Normal Operational Mode. The Life Support Board basically acts as an
interface and summing point between the Master Controller and various
parts in the transmitter when the Master Controller is functioning properly.
2.
Life Support Mode. This mode provides a minimal backup control system
should the Master Controller fail. If the Master Controller board fails, the
Life Support Board disconnects (via AND gates) all signals from the Mas-
ter Controller and allows the transmitter to stay on the air at 1/4 power
with minimal fault protection and no visible monitoring for the operator.
Transmitter functions available in Life Support Mode:
a.
VSWR Protection
b.
System Mute
c.
Transmitter ON (LOW only) and OFF (both LOCAL and REMOTE inputs are
active)
d.
Failsafe
e.
Interlock
4.8.7.1
Normal Operational Mode
The following contains all pertinent circuit operation when the Master Controller is
functioning properly.
4.8.7.1.1 Transmitter Turn On
When the transmitter is turned on, either HIGH or LOW, the Master Controller
generates a high TX-ON signal which enters the Life Support Board at J1-A55 and is
tied to AND gate U26-9. TX-ON is generated when either LOW ON or HIGH ON is
pressed on the front panel, or when a remote HIGH ON is sent from the remote control
system. Since the Master Controller is working, U26-10 is high which sends a high via
U26-8 to OR gate U32-10. This brings U32-8, U32-11 and finally U4-12 high.
Pulse Stretcher, U4
U4 is a pulse stretcher which will output a 100mSec pulse whenever the transmitter ON
button is pressed. Provided there is no power failure signal, POWERFAIL(BAR) from
U37-7, The 100mSec pulse from U4-10 will pass through to U6-13, U8-12 and leaves
the board to reset the PA and PS Controller Boards at J1-A83.
TX_RESTART - Every time an ON command is received, all of the controller boards
will be reset, initializing and clearing any faults. The transmitter will then try to come
Содержание Platinum Z16HD+
Страница 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...