Chapter 3: Operation
Alarms
The table below describes the specific alarms for the HFS6801
+
module. You can only identify specific alarms using a software control
application (for example,
+
Pilot Lite or Pilot). For more information,
see the following:
•
(below) for a list of HFS6801
+
alarms that are logged
and monitored via CCS applications
•
The appropriate software control user manual or online help for
more information
Note
The RefPresAlarm
,
RefLockedAlarm
and RefStdMismatch
alarms are disabled when the Frame Sync Mode parameter is set
to
Delay Mode.
Table 3-7. Alarm Descriptions
Alarm Name
Alarm Description Alarm Level
SDI IP Video Present
Loss of SDI
Major
Video Frozen
Video freeze
Minor
RefPresAlarm Loss
of
reference
Major
RefLockedAlarm Loss
of
reference_locked
Major
RefStdMismatch
Mismatch between
reference video and
video standard
Major
StdMisMtch
Video format selection
error
Major