background image

DA-6804+D Series

Single- and Dual-Channel 3 Gb/s-SDI/HD-SDI/
SD-SDI Power Saving Distribution Amplifiers

Installation and Operation Manual

Edition A
175-100192-00

Содержание DA-DHR6804+D

Страница 1: ...DA 6804 D Series Single and Dual Channel 3 Gb s SDI HD SDI SD SDI Power Saving Distribution Amplifiers Installation and Operation Manual Edition A 175 100192 00...

Страница 2: ......

Страница 3: ...l 1 4 SD SDI Distribution Amplifiers DA HRO6804 D 3 Gb s SDI HD SDI SD SDI Dual Channel Optical and Electrical Distribution Amplifiers DA DHROE6804 D 3 Gb s SDI HD SDI SD SDI Dual Channel Optical to E...

Страница 4: ...clude technical inaccuracies or typographical errors Changes are periodically added to the information herein these changes will be incorporated into new editions of the publication Harris Corporation...

Страница 5: ...ix Product Servicing x Returning a Product x Safety Standards and Compliances x Safety Terms and Symbols x Restriction on Hazardous Substances RoHS Directive xi Waste from Electrical and Electronic E...

Страница 6: ...CCS Navigator Display and Control 33 Operating Notes 34 Setting Locally Controlled Parameters 34 Setting Remotely Controlled Parameters 34 Changing Parameter Settings 47 Recalling Default Parameter S...

Страница 7: ...S6804 D Installation and Operation Manual v Copyright 2010 Harris Corporation Appendix Inspecting and Cleaning Fiber Optic Connections Important Points 60 Inspection 61 Dry Cleaning 61 Wet Cleaning 61...

Страница 8: ...Contents vi Copyright 2010 Harris Corporation...

Страница 9: ...ion amplifier DA DHROE6804 D 3 Gb s HD SDI dual channel optical to electrical distribution amplifier DA DHREO6804 D 3 Gb s HD SDI dual channel electrical to optical distribution amplifier DA DHROO6804...

Страница 10: ...setup Chapter 2 Installation Cleaning fiber optic connections Appendix B Inspecting and Cleaning Fiber Optic Connections Frame setup Chapter 2 Installation Front panel interface Chapter 1 Introduction...

Страница 11: ...if any item is damaged 5 Remove all packaging material from the product and its associated components before you install the unit Table P 3 Manual Style and Writing Conventions Term or Convention Desc...

Страница 12: ...material If the product is still within the warranty period we will return the product prepaid after servicing Safety Standards and Compliances See the 6800 Safety Instructions and Standards Manual t...

Страница 13: ...he EU directive will be marked with a RoHS compliant symbol as shown in Figure P 1 Figure P 1 RoHS Compliance Symbol Waste from Electrical and Electronic Equipment WEEE Directive The European Union EU...

Страница 14: ...About This Manual xii Copyright 2010 Harris Corporation Figure P 2 WEEE Compliance Symbol...

Страница 15: ...D SDI dual channel optical to electrical converting distribution amplifier See page 9 for a list of its main features DA DHREO6804 D is a 3 Gb s HD SD SDI dual channel electrical to optical converting...

Страница 16: ...locally via jumpers on the front edge of the front module with LED display or remotely via RS 232 ports or Ethernet connection using an ICE6800 and 6800 ETH Ethernet connection and Harris CCS control...

Страница 17: ...gnals at data rates from 5 Mb s to 3 Gb s Four selectable channel configurations 1 8_ACO 1 input to 8 outputs with auto changeover The signal on SDI In_1 is distributed to 8 outputs If the signal at S...

Страница 18: ...DH6804 D are listed below Figure 1 2 shows a basic signal flow diagram for this distribution amplifier module Figure 1 2 DA DH6804 D Signal Flow Diagram Operates with standard dual slot distribution a...

Страница 19: ...ures for the DA DSR6804 D are listed below Figure 1 3 shows a basic signal flow diagram for this distribution amplifier module Figure 1 3 DA DSR6804 D Signal Flow Diagram Operates with standard dual s...

Страница 20: ...ain to use external passive 75 2 1 splitter via CCS only Selectable input EQ bypass Reclockable for 270 Mb s SMPTE and DVB ASI signals Three selectable reclocking modes automatic manual enforce bypass...

Страница 21: ...signal on SDI In_1 is distributed to 8 outputs If the signal at SDI In_1 disappears the outputs are switched to SDI In_2 if a signal at SDI In_2 is detected When the signal reappears on SDI In_1 the o...

Страница 22: ...al signal at SDI In_1 disappears the outputs are switched to Optical input at SDI In_2 if an Optical signal at SDI In_2 is detected When the Electrical signal reappears on SDI In_1 the outputs are aut...

Страница 23: ...re listed below Figure 1 6 shows a basic signal flow diagram for this distribution amplifier module Figure 1 6 DA DHROE6804 D Signal Flow Diagram Operates with dual slot RR optical distribution amplif...

Страница 24: ...tic bypassing reclock stage if not relockable Reclock status and data rate report Automatic slew rate control for electrical output signal Automatic power saving if not input signal or no termination...

Страница 25: ...1 optical output and 3 electrical outputs Electrical In_B to Out_B 1 optical output and 3 electrical outputs Input signal presence detect and report Automatic input cable equalization for electrical...

Страница 26: ...cal outputs If the signal at In_A disappears the outputs are switched to In_B if an optical signal at In_B is detected When the signal is reappears In_A the outputs are automatically switched back to...

Страница 27: ...and data rate report Automatic slew rate control for electrical output signal Optical output protection enable Optical output loss alarm Optical status for optical output by CCS Automatic power saving...

Страница 28: ...ure 1 9 DA 6804 D Series Front Module Back Modules DA 6804 D series modules can be installed with double width back modules in their respective host frames These modules cannot be installed in 6800 70...

Страница 29: ...ications on page 52 Table 1 2 describes the maximum allowable power ratings for 6800 frames Note the given maximums before installing any 6800 modules in your frame DA 6804 D series modules cannot be...

Страница 30: ...Chapter 1 Introduction 16 Copyright 2010 Harris Corporation...

Страница 31: ...s Before you install DA 6804 D series modules perform the following Remove the anti static shipping pouch if present and all other packaging material Retain the original packaging materials for possib...

Страница 32: ...ual Channel Distribution Amplifier DA DH6804 One DA DH6804 front module One DA 6804 Series Installation and Operation Manual DA DH6804 D One DA DH6804 front module One standard double slot BNC back co...

Страница 33: ...tion amplifier back connector module One DA 6804 Series Installation and Operation Manual DA DHREO6804 D 3G HD SD ASI Dual Channel Electrical to Optical Distribution Amplifier DA DHREO6804 D One DA DH...

Страница 34: ...etup consists of installing a frame into its rack and then connecting to a power and or Ethernet source See the appropriate frame installation and operation manual for details on installing and operat...

Страница 35: ...CCS software installed Figure 2 2 Connection for CCS Control Setting Up Back Connector Modules Back module setup consists of plugging in coaxial cables A and fiber optical cables B as shown in Figure...

Страница 36: ...for channel 2 The reclocker remains in AUTO mode if no shunt is on any position of the jumper Table 2 2 J1 and J2 Jumper Settings Jumper Selection Pin Setting Label Description J1 J2 1 2 AUTO_1 2 Inpu...

Страница 37: ...umper Selection Pin Setting Label Description J3 1 2 1 8_ACO Locally configures distribution amplifier as single channel 1 8 with ACO J3 3 4 1 8_IN1 Locally configures distribution amplifier as single...

Страница 38: ...tructions and Standards Manual for important information about safely installing your module Once you have installed the modules you can connect them to the appropriate input and outputs SFPs on DA 68...

Страница 39: ...equired frame slot and then screwing it into place 4 Follow the fiber cable inspection and cleaning procedure that begins on page 59 5 Insert the front module into the slot holding the corresponding b...

Страница 40: ...Chapter 2 Installation 26 Copyright 2010 Harris Corporation...

Страница 41: ...ate properly Usually there is no need for other operational changes Without a CCS remote control system DA 6804 D series distribution amplifiers are fully functional in FR6802 frames With an installed...

Страница 42: ...s System Status Indicators Signal Condition Indicators Each 6800 module has a number of LEDs assigned to indicate varying states functions These functions are listed in Table 3 2 Table 3 1 System Stat...

Страница 43: ...hts red Figure 3 2 Alarm Indicator System Status LED Figure 3 3 Alarm Indicator Frame Front 270 Green Input signal is reclocked at 270 Mb s Off Input signal is not reclocked 1 5G Green Input signal is...

Страница 44: ...ut signal for channel 1 is lost or absent Major Ch 2 loss of input Indicates input signal for channel 2 is lost or absent Major Ch 1 loss of lock Indicates signal for channel 1 is not locked Major Ch...

Страница 45: ...rol Interface display A view of the frame modules components is displayed on screen Figure 3 4 Web Enabled Control Display A tree view of the frame and its contents is displayed at the left of the scr...

Страница 46: ...display boxes on the pane the value of read only parameter is displayed as grey ground with black characters and you cannot change it The adjustable parameter value is displayed as white ground with...

Страница 47: ...rol mode a control pane is displayed on screen of the computer monitor When you select the frame and slot for a distribution amplifier module location the software displays the item values on the cont...

Страница 48: ...he REMOTE Reclocking mode and control mode parameters are available for local control The J1 and J2 jumpers are used to determine reclocking mode Table 2 2 on page 22 describes parameters that are acc...

Страница 49: ...Enabled Enables or disables the Loss of Input alarm for channel 1 Ch 2 Loss of Input Alarm Disabled Enabled Enables or disables the Loss of Input alarm for channel 2 Current Input RO NOTE Only valid...

Страница 50: ...Reports loss of signal or termination fault for the corresponding output Out 2D Cable Fault RO Yes No Reports loss of signal or termination fault for the corresponding output Ch 1 Data Rate RO Unknow...

Страница 51: ...2 1 8 2 4 Selects module output configuration as dual 1 4 or 1 8 1 input routed to all outputs or 1 8 with input 2 routed to all outputs Ch 1 Signal Present RO No Yes Indicates if the input signal for...

Страница 52: ...corresponding output Out 1C Cable Fault RO Yes No Reports loss of signal or termination fault for the corresponding output Out 1D Cable Fault RO Yes No Reports loss of signal or termination fault for...

Страница 53: ...1 Rx Power RO 0 000 mW to 6 535 mW Internally measured receiver power on optical channel 1 Table 3 5 DA HRO6804 Remotely Controlled Parameters Continued Bold text Default setting RO Read only feedback...

Страница 54: ...Hysteresis 0 1 second to 0 5 seconds Value used to determine how long a condition that is signal presence must be asserted before it is reported to the control system Green Mode Enabled Disabled Enab...

Страница 55: ...te for channel 2 input Ch1 Loss of Lock Alarm Disabled Enabled Enables or disables the Loss of Lock alarm on channel 1 the Loss of Lock alarm indicates the signal is not locked Ch2 Loss of Lock Alarm...

Страница 56: ...nput Alarm Disabled Enabled Enables or disables the Loss of Input alarm for channel 2 Current Input RO NOTE Only valid in 1 8 with ACO mode output configuration N A Ch 1 Ch 2 Indicates if the input si...

Страница 57: ...esponding output Out 2C Cable Fault RO Yes No Reports loss of signal or termination fault for the corresponding output Out 2D Cable Fault RO Yes No Reports loss of signal or termination fault for the...

Страница 58: ...module Other Output Config Ch 1 1 8 with ACO Ch 1 1 8 Ch 2 1 8 2 4 Selects module output configuration as dual 1 4 or 1 8 1 input routed to all outputs or 1 8 with input 2 routed to all outputs Ch 1 S...

Страница 59: ...fault for the corresponding output Out 1C Cable Fault RO Yes No Reports loss of signal or termination fault for the corresponding output Out 1D Cable Fault RO Yes No Reports loss of signal or termina...

Страница 60: ...Dual Transmitter 1A Unknown Transceiver 2A Dual Receiver 2A Dual Transmitter 2A Displays the SFP type present in SFP slot 1 Ch 1 Rx Power RO 0 000 mW to 6 535 mW Internally measured receiver power on...

Страница 61: ...nstallation and operation manual for instructions on how to change parameter settings Recalling Default Parameter Settings You cannot recall default parameter settings for these modules Reading the So...

Страница 62: ...Chapter 3 Operation 48 Copyright 2010 Harris Corporation...

Страница 63: ...HR6804 D 2 DA DH6804 D 2 DA DSR6804 D 2 DA DS6804 D 2 DA HRO6804 D 1 DA DHROE6804 D 0 DA DHREO6804 D 2 DA DHROO6804 D 0 Signal type 3G SDI HD SDI SD SDI ASI Connector BNC per IEC169 8 Impedance 75 Ret...

Страница 64: ...r Optical Channel Input Specifications Item Specification Number of inputs DA HRO6804 D 1 DA DHROE6804 D 2 DA DHROO6804 D 2 Wavelength 1260 1610 nm Signal type 3G SDI HD SDI SD SDI ASI Connector LC Ov...

Страница 65: ...169 8 Impedance 75 Return loss 15 dB 5 MHz to 1 5 GHz 10 dB 1 5 GHz to 3 0 GHz Signal amplitude 800 mV 10 DC offset 0 0 V 0 5 V Rise and fall time 3G SDI HD SDI SD SDI ASI 135 ps 270 ps 400 700 ps Ove...

Страница 66: ...SDI SD SDI ASI 0 3 UI 0 2 UI Table 4 4 Fiber Optical Channel Output Specifications Continued Item Specification Table 4 5 Temperature Specifications Item Specification Performance 41 to 104 F 5 to 40...

Страница 67: ...systems use semiconductor laser transmitters that emit infrared IR light at wavelengths between approximately 800 nanometers and 1600 nanometers The emitted light is above the red end of the visible...

Страница 68: ...ng the distance reduces the irradiance by a factor of 4 and rapidly decreases over distance Lasers and Eye Damage The optical energy emitted by laser and high radiance LEDs in the 400 1400 nm range ma...

Страница 69: ...ical fiber communication system is totally enclosed and presents no risk of eye injury It is a Class I 1 system under the FDA and IEC classifications The fiber optic cables that interconnect various c...

Страница 70: ...rminal equipment WARNING Eye damage may occur if an optical instrument such as a microscope magnifying glass or eye loupe is used to stare at the energized fiber end Precautions for Unenclosed Systems...

Страница 71: ...uidance on the safe use of optical fiber communication systems in the workplace consult ANSI Z136 2 American National Standard for Safe Use of Lasers in the U S or outside the U S IEC 60825 Part 2 Spe...

Страница 72: ...Appendix A Laser Safety Guidelines 58 Copyright 2010 Harris Corporation...

Страница 73: ...typical contaminants of a fiber optic connection The inspection and cleaning procedure begins on page 61 Table B 1 Typical Contaminants Contaminant Comments Dust particle 1 micron Can block up to 1 o...

Страница 74: ...ber Store unused protective caps in a clean resealable container located nearby for easy access Do not reuse cleaning tissues or swabs Do not allow alcohol or another wet cleaning agent to dry on a fi...

Страница 75: ...xcessive rubbing will leave scratches 3 Repeat the wiping action on another clean section of the wipe or a new wipe 4 Inspect the connector again with the fiberscope 5 If the connection is clean retur...

Страница 76: ...7 If the contamination persists repeat the dry and wet cleaning procedure until the endface is clean If the fiber end still remains dirty after repeated cleaning attempts call Customer Service for fu...

Страница 77: ...ture 52 DA DHREO6804 D features 10 parameters 42 signal flow diagram 10 specifications inputs electrical 49 outputs electrical 51 power consumption 52 start up time 52 temperature 52 DA DHROE6804 D fe...

Страница 78: ...ctronic Equipment xi E Electrical channel input specifications 49 output specifications 51 F G Features DA DH6804 D 4 DA DHR6804 D 3 DA DHREO6804 D 10 DA DHROE6804 D 9 DA DHROO6804 D 12 DA DS6804 D 7...

Страница 79: ...eters 34 Power consumption specifications 52 Power ratings 15 Power up time 52 Precautions laser safety 55 57 Protective laser connector covers 25 R Remotely controlled parameter list 34 46 Removing m...

Страница 80: ...ion Start up time 52 System status indicator LEDs 28 T Temperature specifications 52 TX fault See SPF transmitter fault alarm U Unpacking modules ix V Versions reading 47 W Z Waste from Electrical and...

Отзывы: