2-10
888-2685-001
12/24/07
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation Verification &
Ranger Commissioning Manual
2.9
Motorized RF Switch Connections (if equipped)
IMPORTANT:
If no patch panel or motorized RF switch is to be installed in the transmitter RF
output line, or if the RF switch does not have status switches, then a jumper must
be placed on the External I/O board from J14-3 (RF_SW_A_STAT) to J14-1
(ground).
NOTE:
Refer to the Ranger External I/O Connections schematic 843-5560-105 for the
following connections: (S1 = Antenna position / S2 = Test Load position)
The RF_SW_SEL_OUT at J15-9 on the External I/O board is connected to the
select input on the switch. This output is a TTL open collector, active low, momentary
signal meant to cause a switch to the opposite position. The RF switch should then latch
in that position until pulsed again.
One side of S1A and S2A (interlock switches on the rf switch) is connected to J18-9
and the other side to J18-10 on the External I/O Board in the transmitter. See
diagram 843-5560-105 and/or 843-5549-141 sheet 20, for RF Mute interlock
connections. This is one of the transmitter rf mute interlock inputs and will mute the
transmitter while the switch changes position. Another jumper must be connected
between J18-11 & J18-12 to operate the transmitter.
If the patch panel has status switches then S1B and S2B are connected to the RF
switch status inputs on J14 of the External I/O Board in the transmitter. This
allows the GUI to display the position of the patch panel and will cause a transmitter
mute if neither of these connections are pulled low. These connections include:
•
S1B and S2B commons connect to J14-1 (ground)
•
S1B (antenna position) connects to J14-3
•
S2B (test load position) connects to J14-4
NOTE:
If the patch panel does not have status switches then a jumper must be placed
between J14-1 (ground) and J14-3 (RF_SW_A_STAT) on the External I/O board.
The transmitter will be muted without this connection.
Confirm that the jumpers in the External I/O board for all unused External
Interlocks are installed. See "2.7.1 External Interlocks" on page 2-8 for information
on connections. If no external interlocks are used, connect J18-1 to J18-8.
Содержание CZ1000F
Страница 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 7: ......
Страница 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 11: ......
Страница 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...
Страница 16: ...Table of Contents continued 4 888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...