WARNING: Disconnect primary power prior to servicing.
Ranger Commissioning Manual
Section 6
ISP (In-System
Programming)
6
6.1
Introduction
This section provides step by step procedures for updating the software loaded onto
each of the controllers in the Ranger transmitter via the In-System Programming feature
or ISP. This allows for software updates without having to change firmware ICs. The
ISP program and the software files for each of the controllers is supplied on the CD-
ROM which came with the transmitter, along with an acrobat version of the technical
manual. The ISP program requires an external Windows PC with an available RS-232
serial port which can be connected to the Main Controller board. This single connection
(via ISP bridging) will allow updating of all controllers, including:
•
Main Controller Bd
•
PS Monitor Bd
•
RF Monitor Bd
•
External I/O Bd
NOTE:
The PA Modules require a different serial connection point and therefore have a
separate ISP procedure than the 4 controllers mentioned above.