4-44
888-2685-001
12/24/07
WARNING: Disconnect primary power prior to servicing.
Ranger Commissioning Manual
Section 4 RF Testing
4.3.5.1
For the FSQ
a.
Press the “SETUP” key. Press the “GENERAL SETUP” soft key and then the
“CONFIGURE NETWORK” softkey.
b.
Using the arrow keys or knob, select the desired Local Area Connection and the
press the enter key.
c.
The LAN status dialog box appears, select “Properties” and press enter.
d.
Using the arrow keys select “Internet Protocol (TCP/IP)”, and then use the knob
to select properties and press enter.
e.
Enter an IP address and Subnet mask. The following is suggested:
1.
IP address: 10.46.252.190
2.
Subnet mask: 255.255.255.0
4.3.5.2
For Linux Laptop
a.
Log on to Linux laptop
1.
Username: root
2.
Password: M3diaFL0
b.
Open a new terminal by right clicking on the desktop and selecting “New
Terminal” from the drop down menu.
c.
Go to the processing main menu by typing:
1.
cd_/local/mnt/pp/automation
2.
./PROCESSING
d.
Change the Linux machines settings for the FSQ’s IP address.
1.
Enter “6” and press “ENTER”.
2.
Enter the static IP address which was set for the FSQ. The suggested FSQ
IP address is 10.46.252.190
e.
Set the Linux machine to have a static IP address similar to the FSQ:
1.
Enter “4” and press “ENTER”.
2.
Enter “1” and press “ENTER”.
3.
Enter the IP address and press “ENTER”. The suggested IP address is
10.46.252.189
4.
Enter the subnet mask and press “ENTER”. The suggested subnet mask is
255.255.255.0
Содержание CZ1000F
Страница 4: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing MRH 2...
Страница 5: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 7: ......
Страница 9: ...12 24 07 888 2685 001 WARNING Disconnect primary power prior to servicing...
Страница 11: ......
Страница 12: ...888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...
Страница 16: ...Table of Contents continued 4 888 2685 001 12 24 07 WARNING Disconnect primary power prior to servicing...