APEX
™
Exciter Incorporating FLO
™
Technology
Navigating the LCD Display Screens
Details of the System Setup Screens
Page: 3-52
888-2604-001
03/08/07
WARNING: Disconnect primary power prior to servicing.
Frame Length = (Superframe Length – Pos. Pilot Length – 18) / 4;
•
Local Length:
(Unsigned Decimal integer, displayed only, not user configurable –
see below)
Local Length shall be calculated, written to the FPGA register, and displayed based
on the following formula:
Local Length = Frame Length – National Length – 4;
3.6.7.5
FPGA Configure 5/5, Restore Defaults
FPGASetup5.bmp
Figure 3-44 FPGA Configure 5/5, Restore Defaults
FPGA Configure 5/5 screen consists of the following four buttons.
• Restore Factory (Defaults)
• Restore Defaults
• Initialize FPGA
• Save as Defaults
Restore Factory Defaults
loads all FPGA registers with the values defined as default
initialization values in the API, if defined, followed by a re-initialization of the FPGA.
Save as Defaults
saves the current GUI settings that may have been modified by the user,
in non-volatile memory as default values for subsequent initialization and startup.
Restore Defaults
recalls the previous set of values saved as default, followed by a
re-initialization of the FPGA.
Initialize FPGA
manually starts the initialization sequence defined in the API, using the
current values indicated in the GUI.
Note: Restore Factory Defaults and Restore Defaults causes a warning window to pop up.
It states “WARNING: Restore will re-initialize exciter.”
• Clicking OK will start the restore and re-initialize process.
• Clicking cancel will abort the restore and re-initialization sequence.