Chapter 2 System Installation with the Content-
Server 4000 Series
© 2017 Harmonic Inc. All rights reserved.
61
Harmonic MediaGrid Release 4.1
Connecting the Harmonic MediaGrid 4000 System Components
Figure 2–21: High Bandwidth ContentBridges connected in an HA pair to the network switch
Connecting the ContentServer 4000 to the ContentStore 4240
You can connect up to four ContentStore 4240 storage arrays to a single ContentServer 4000.
Each ContentStore attaches directly to the ContentServer.
NOTE:
When connecting the ContentServer to the ContentStore, be careful to not twist the SAS cables,
bundle them with power cables, or inadvertently braid the cables together.
1. On Controller A on the ContentServer, connect a SAS cable to an open SAS port. Connect the
other end of the cable to SAS-1 on the top expander module on the ContentStore 4240.
2. On Controller B of the ContentServer, connect a SAS cable to an open SAS port. Connect the
other end of the cable to SAS-1 on the bottom expander module of the ContentStore 4240.
3. Continue to connect the remaining ContentStore nodes to the ContentServer in the same
manner.
Customer Core Switch
To Harmonic MediaGrid Network
ContentBridge 2010F
ContentBridge 2010F
2
3
1
1
2
3