L-Band Power
Use the L-Band Power parameter to set the L-band output power in dBm units. The L-Band power
is required for Carrier definitions. Configuration of this parameter is saved automatically and does
not require you to access the
Save
menu.
The range is -50 to -7 dBm. The L-Band Power default value is -
20 dBm
.
Front Panel
To set the L-Band Power parameter on the front panel:
1. Navigate
Root > L-Band Modulation and Up-Converter > L-Band Power
.
2. Adjust the value with the up and down arrow keys.
3. Press
<Enter>
.
Web Manager
To set the L-Band Power parameter in the Web Manager:
1. Select
DSNG > Modulator and Up-Converter
. See Figure 11–2.
2. Set the Carrier parameter to
Operational
.
3. Set the L-Band Power parameter.
L-Band Power
-7 [dbm]
<-50 - -7>