Chapter 10 Unit Configuration
© 2013 Harmonic Inc. Harmonic All rights reserved.
281
Ellipse 3000 Release 3.0, Rev. B
Ellipse System Sub-Menu/Tab
10.3.8
BOOTP Control Menu
The Bootstrap Protocol (BOOTP) Control menu allows setting the basic parameters for managing
the operation of the BOOTP software updating protocol.
NOTE:
The BOOTP software update protocol is performed using the NMX application.
The available options are:
■
BOOTP Activation
– Enables/Disables updating the encoder software using BOOTP.
■
BOOTP Retries Count
– Sets the number of update tries for the BOOTP before failure is
declared. The range is 01 to 10 tries.
■
BOOTP Retry Time Out
– Sets the time out for each BOOTP try. The range is 01 to 10 sec.
Front Panel
To access the
BOOTP Control
menu on the front panel:
❖
Navigate
Root > Configuration > Unit > System > BOOTP Control
.
Web Manager
To access the
BOOTP Control
parameters in the Web Manager:
❖
Select
Unit > System
.
BOOTP Control
1 BOOTP Activation
Disabled
2 BOOTP Retries Count
10
3 BOOTP Retry Time Out
01