Chapter 4 Transport Stream Configuration
© 2013 Harmonic Inc. Harmonic All rights reserved.
102
Ellipse 3000 Release 3.0, Rev. B
M-SPTS Sub-Menu/Tab
4.3.2.3
M-SPTS PID Management (Add / Drop PID)
Adding or dropping of PID from the M-SPTS is done differently when using the encoder front
panel or the encoder web manager.
NOTE:
PID duplication between services is not supported in the current version.
Adding an M-SPTS PID (Front Panel)
To add an M-SPTS stream using the front panel:
1. Navigate
Root > Configuration > Transport Stream > M-SPTS > Transports List >
[Stream Name] > Add PID
.
2. Select the Select PID to add option in the menu to display a list of PIDs not yet attached to the
stream in order to select the PID to add.
3. Press
<Enter>
.
The menu returns to the Add PID screen displaying the selected PID.
4. Select
Add
to add the selected PID to the stream.
Dropping an M-SPTS PID (Front Panel)
To drop an M-SPTS stream using the front panel:
1. Navigate
Root > Configuration > Transport Stream > M-SPTS > Transports List >
[Stream Name] > Drop PID
.
2. Select the Select PID to drop option in the menu to display a list of PIDs attached to the
stream in order to select which PID to drop.
3. Press
<Enter>
.
The menu returns to the List/Drop PID screen displaying the selected PID.
4. Select
Drop
to drop the selected PID from the stream parameters.
Add PID
1 Select PID to add
second-service I..
2 Add
List/Drop PIDD
1 Select PID to drop
MPE PID 1382
2 Drop