background image

 28

VC-Strip Safety and Installation Guide

VC-Strip 8x1

Peak heat dissipation (calculated, at full intensity, full white). . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 BTU/hr.
Typical heat dissipation (calculated, with typical video content)  . . . . . . . . . . . . . . . . . . . . . . . . .5.5 BTU/hr.

Figures for typical video content are indicative only and will vary

Approvals

EU safety  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN 60950-1
EU EMC . . . . . . . . . . . . . . . . . . . . . EN 55103-1, EN 55103-2, EN 55022,

. . . . . . . . . . . . . . . . . . . . . . . . .  EN 55024, EN 61000-3-2, EN 61000-3-3

US safety  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  UL 60950-1
US EMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FCC Part 15 Class A
Canadian safety . . . . . . . . . . . . . . . . . . . . . . . . .  CSA C22.2 No. 60950-1
Canadian EMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  ICES-003 Class A
Australia/NZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-Tick N4241

Accessories

Mounting accessories

VC-Grid™ and VC-Strip™ Mounting Frames, set of 10  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 91611370

Input cables

Hybrid Input Cable, 4-pin male XLR to PCB connector, 0.25 m (0.8 ft.)  . . . . . . . . . . . . . . . .  P/N 11840158
Hybrid Input Adapter Cable, 5-pin male XLR + two cable

tails to 4-pin female XLR, 0.25 m (0.8 ft.). . . . . . .  P/N 11840171

Hybrid Input Adapter Cable, 5-pin male XLR + Tripix Power

IP66 to 4-pin female XLR, 0.25 m (0.8 ft.) . . . . . .  P/N 11840194

VC-Strip to VC-Strip link cables

Hybrid Link Cable, PCB to PCB, 200 mm (7.9 in.). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 11840160
Hybrid Link Cable, PCB to PCB, 400 mm (15.7 in.). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 11840161
Hybrid Link Cable, PCB to PCB, 600 mm (23.6 in.). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 11840162
Hybrid Link Cable, PCB to PCB, 800 mm (31.5 in.). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 11840163
Hybrid Link Cable, PCB to PCB, 1000 mm (39.4 in.). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 11840157

Extension cables

Hybrid 4-pin XLR Extension Cable, 1 m (3.3 ft.)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 11821016
Hybrid 4-pin XLR Extension Cable, 2.5 m (8.2 ft.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 11821017
Hybrid 4-pin XLR Extension Cable, 5 m (16.4 ft.)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 11821018
Hybrid 4-pin XLR Extension Cable, 10 m (32.8 ft.)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 11821019
Hybrid 4-pin XLR Extension Cable, 25 m (82.0 ft.)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 11821015

Output / throughput cables

Hybrid Output/Thru Cable, PCB to 4-pin female XLR, 0.25 m (0.8 ft.)  . . . . . . . . . . . . . . . . .  P/N 11840159
Data Output/Thru Cable, 4-pin male XLR to 5-pin female XLR, 0.25 m (0.8 ft.)  . . . . . . . . . .  P/N 11840203

Hybrid cables carry both DC power and data over separate conductors.

Related Items

P3 PowerPort 1500™  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 90721040
P3-100™ System Controller  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 90721010
P3-200™ System Controller  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 90721020
P3-PC™ System Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 90721030
Tripix Power IP66™ Power Supply Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 90760330

See www.martin.com for latest information

Содержание Martin VC-Strip 90357280

Страница 1: ...VC Strip User Manual...

Страница 2: ...jury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document The Martin logo...

Страница 3: ...0 Installing a P3 system 10 Installing a DMX controlled system 12 Connecting additional devices to a VC Strip chain 17 System setup 18 Setting up for P3 display 18 Setting up for DMX control 18 Settin...

Страница 4: ...thorized service agents Important The VC Strip is not designed to allow hot plugging Shut down power and data before connecting or disconnecting modules If you have any questions about how to operate...

Страница 5: ...d made impossible to reapply even accidentally during work on the installation Shut down power to the installation during service and when it is not in use Before applying power to the installation ch...

Страница 6: ...00 and simple cabling system The VC Strip is available in eight models Two lengths are available VC Strip 16x1 25 with 16 LEDs per module VC Strip 8x1 25 with 8 LEDs per module and each length is avai...

Страница 7: ...view 7 VC Strip overview Figure 1 Overview C B A A Control button B 48 VDC power data throughput THRU C 48 VDC power data input IN D Module cutting points VC Strip 16x1 25 only D D D D VC Strip 16x1 2...

Страница 8: ...marking at the upper edge of the modules Allow free airflow around the product and at least 10 mm 0 4 in of clearance around the LEDs on the front surface To maintain 25 mm pixel spacing across multip...

Страница 9: ...Strip modules However if you create a chain of VC Strip 16x1 modules in which ALL the modules in the chain have been shortened you can increase the maximum permitted number of modules slightly from th...

Страница 10: ...CB cables see VC Strip to VC Strip link cables on page 28 Connect each cable from the THRU connector of one VC Strip to the IN connector of the next VC Strip to create the chain Warning Each chain tha...

Страница 11: ...mains power and power the controller on You can now configure the system at the P3 controller See System setup on page 18 Max 45 VC Strip 16x1 modules or 60 VC Strip 8x1 modules total per chain Max 4...

Страница 12: ...of DMX channels the VC Strips will use and the 512 DMX channels available in one DMX universe at the DMX controller Each time you have used 512 channels you must create a new DMX link that is connect...

Страница 13: ...r if used Hybrid to PCB adapter cable Hybrid extension cable if needed Hybrid extension cable if needed Hybrid PCB to PCB cable Hybrid PCB to PCB cable Max 30 VC Strip 16x1 25s or 60 VC Strip 8x1 25s...

Страница 14: ...dapter cable Suitable extension cables are available from Martin in various lengths See Extension cables on page 28 7 See Figure 8 Connect the DC power input connector of a Martin Tripix Power IP66 hy...

Страница 15: ...cable lead in cable Hybrid extension cable if needed Hybrid extension cable if needed Hybrid PCB to PCB cable Hybrid PCB to PCB cable See text for maximum number of of VC Strips per hybrid link See t...

Страница 16: ...gths See Extension cables on page 28 7 See Figure 10 If the PSU does not have constant overcurrent protection that will limit current to 8 A on the DC output used install an inline fuseholder with a 7...

Страница 17: ...4 W per VC Strip 8x1 25 module then add the power consumption of each device that you add to the end of the chain As soon as you reach 360 W or the maximum power rating of the device that you use to s...

Страница 18: ...he same DMX channels three channels for RGB products and one channel for WW MW and CW products If VC Strips are set up for individual pixel control each of the 16 LEDs on a module is controlled by its...

Страница 19: ...entically Setting up via RDM using Martin M PC Using an RDM compliant DMX controller such as Martin M PC you can communicate with the VC Strip modules on the DMX data link via RDM You can Retrieve dat...

Страница 20: ...are controlled as one group To set a VC Strip module to pixel or module mode calibrated or raw using M PC open the RDM View window and click on Scan to display a list of the elements in the installat...

Страница 21: ...LEDs and reset the VC Strip Status display To display a VC Strip module s status press the control button once LEDs 1 4 will give one of the indications listed in the tables below for a few seconds VC...

Страница 22: ...MX source to the network LEDs 1 and 2 Flashing Ready VC Strip connected to P3 controller but not receiving valid P3 data stream Set up the P3 controller to use the VC Strip LEDs 1 and 2 Constant Runni...

Страница 23: ...sses display the following test patterns on the LEDs one short press scrolls to next pattern Calibrated white 100 White 33 White 33 White 33 Scrolling gradient Press and hold until LEDs 1 and 3 light...

Страница 24: ...ip In extreme cases the product may require cleaning after surprisingly few hours of operation Environmental factors that may result in a need for frequent cleaning include Use of smoke or fog machine...

Страница 25: ...Do not attempt repairs yourself Contact Martin Service or an authorized Martin service partner for assistance VC Strip does not display as intended Bad 48 VDC power transmission Inspect connections a...

Страница 26: ...controller or RDM compliant DMX controller Control resolution 16 bit P3 or 8 bit DMX control of each color Color and intensity calibration Pixel level Video signal compliance Martin P3 proprietary vid...

Страница 27: ...ting See details in user manual Figures allow for cable in a chain with a total hybrid cable length of 50 m Connections Power data input 4 pin Molex male PCB connector Power data thru 4 pin Molex fema...

Страница 28: ...o VC Strip link cables Hybrid Link Cable PCB to PCB 200 mm 7 9 in P N 11840160 Hybrid Link Cable PCB to PCB 400 mm 15 7 in P N 11840161 Hybrid Link Cable PCB to PCB 600 mm 23 6 in P N 11840162 Hybrid...

Страница 29: ...ve 2003 108 EC where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of Marti...

Страница 30: ......

Страница 31: ......

Страница 32: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Отзывы: