ERA 700 Performance IP Safety and Installation Manual Rev. C
5
Technical Support
If you have questions about how to install or operate the fixture safely, please contact
Harman Professional Technical support:
•
For technical support in North America, please contact
[email protected]
Phone: (844) 776-4899
•
For technical support outside North America, please contact your national distributor.
Protection from electric shock
The ERA 700 Performance IP has an ingress protection rating of:
•
IP66 if the anti-tamper box is installed on the connections panel with the cable openings
facing downwards, and
•
IP65 without the anti-tamper box.
To achieve an IP66 rating, keep the fixture’s anti-tamper box installed over the connections
panel with the cable openings in the anti-tamper box facing downwards at all times. Remove
the box only temporarily for access to the connectors during installation or maintenance
work.
The fixture can withstand rain, splashing water, condensation etc. The fixture is designed to
be used under any weather conditions, but do not expose it to an artificially high volume of
water (in a fountain, waterfall or shower, for example). Do not immerse it. Do not expose it to
high-pressure water jets. Isolate the fixture from power immediately if extreme conditions
such as flooding arise.
The fixture is rated IP65/IP66 only when connectors with a corresponding IP rating are used
on cables connected to the fixture.
Use only connectors and cables that are suitable for the installation environment and
application with respect to humidity, water and sunlight resistance.
The power and data connectors are fitted with rubber caps to protect from water ingress.
Keep rubber caps installed at all times on all connectors that are not in use.
Arrange cables so that they arrive at connectors from below.
Create a ‘drip loop’ if necessary (see drawing on right). With
this arrangement, gravity will cause any condensation or
water droplets to run away from connectors.
Support the weight of cable runs. Do not allow a length of
cable to hang from a connector.
In wet locations, install the fixture with the connections panel
facing downwards.
The fixture accepts AC mains power at 100-240 V~
(nominal), 50/60 Hz. Do not connect the fixture to mains
power that is not within this range.
The fixture has a maximum total power consumption of 990 W.
The fixture draws a maximum total current of 11.1 A at 100-120 V~ and a maximum total
current of 3.7 A at 200-240 V~.
The fixture draws a typical half-cycle RMS inrush current of 14.0 A for the first 10
milliseconds when mains power is first applied to the fixture at 230 V~, 50 Hz.
To connect the fixture to mains power, you must first obtain 12 AWG or 2.5 mm
2
power input
cable that is 16 A rated and temperature-rated to suit the installation environment. In the
USA and Canada, the cable must be UL-listed, type SJTW or equivalent. In the EU, the
cables must be type H05VV-F or equivalent. Suitable cables with the correct connectors are
available from Martin.
Drip loop