Harman Martin DMX PowerPort 375 Series Скачать руководство пользователя страница 18

 18

DMX PowerPort 375™ User Manual

Electrical

AC mains power input  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  100-240 V (nominal), 50/60 Hz
Power supply unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auto-ranging electronic switch-mode
Maximum permitted total current draw from 48 VDC OUT at 100-120 V mains power . . . . . . . . . . . . . . 5 A
Maximum permitted total current draw from 48 VDC OUT at 173-240 V mains power . . . . . . . . . . . . .7.5 A
Main fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . Double-pole/neutral fusing, 2 x T6.3 A (slow-blow), 250 VAC
Maximum total power consumption . . . . . . . . . . . . . . . . . . 450 W (including full load of connected fixtures)
Typical half-cycle RMS inrush current at 230 V, 50 Hz  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.6 A
Typical earth leakage current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.7 mA

Thermal

Maximum ambient temperature (T

a

 max.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  45° C (113° F)

Minimum ambient temperature (T

a

 min.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -20° C (-4° F)

Cooling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filtered forced air (temperature-regulated, low-noise)
Total heat dissipation (calc/- 10%)  . . . . . . . . . . . . . . . . . . . . 300 BTU/hr. (not including connected

fixtures but with system at full load)

Approvals

EU safety . . . . . . . . . . . . . . . . . . . . . . . . . IEC/EN 60950, IEC/EN 62368-1
EU EMC  . . . . . . . . .  EN 55032, EN 55035, EN 61000-3-2, EN 61000-3-3
US safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ANSI/UL 62368-1
US EMC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FCC 47 CFR 15 Class B
Canadian safety. . . . . . . . . . . . . . . . . . . . . . . . . .  CSA C22.2 No. 62368-1
Canadian EMC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  ICES-003 Class B
Australia/NZ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AS/NZS 62368:1:2018

Included Items

1 x Safety Cable Attachment Eyelet, incl. screws
2 x Short Rack Mounting Ears, incl. screws
1 x Long Rack Mounting Ear, incl. screws
1 x Coupling Plate, incl. screws
User Manual

Please note that a power input cable is not supplied with the product and must be ordered separately (see 
below)

Accessories

Power Input Cables

Power Input Cable, H07RN-F, 2.5 mm², bare ends to TRUE1, 1.5 m (4.9 ft.) . . . . . . . . . . . .  P/N 91611797
Power Input Cable, H07RN-F, 2.5 mm², bare ends to TRUE1, 5 m (16.4 ft.). . . . . . . . . . . . .  P/N 91611786
Power Input Cable, SJOOW, 12 AWG, bare ends to TRUE1, 1.5 m (4.9 ft.) . . . . . . . . . . . . .  P/N 91610173
Power Input Cable, SJOOW, 12 AWG, bare ends to TRUE1, 5 m (16.4 ft.)  . . . . . . . . . . . . .  P/N 91610174

Power Thru Cables

Power Relay Cable, H07RN-F, 2.5 mm², TRUE1 to TRUE1, 0.45 m (1.5 ft.) . . . . . . . . . . . . .  P/N 91611784
Power Relay Cable, H07RN-F, 2.5 mm², TRUE1 to TRUE1, 1.2 m (3.9 ft.) . . . . . . . . . . . . . .  P/N 91611785
Power Relay Cable, H07RN-F, 2.5 mm², TRUE1 to TRUE1, 2.5 m (8.2 ft.) . . . . . . . . . . . . . .  P/N 91611796
Power Relay Cable, SJOOW, 12 AWG, TRUE1 to TRUE1, 0.45 m (1.5 ft.). . . . . . . . . . . . . .  P/N 91610170
Power Relay Cable, SJOOW, 12 AWG, TRUE1 to TRUE1, 1.2 m (3.9 ft.). . . . . . . . . . . . . . .  P/N 91610171
Power Relay Cable, SJOOW, 12 AWG, TRUE1 to TRUE1, 2.5 m (8.2 ft.). . . . . . . . . . . . . . .  P/N 91610172

Power Connectors

Power Connector, Cable Mount, Neutrik TRUE1 NAC3FX-W (female) . . . . . . . . . . . . . . .P/N 91611789HU
Power Connector, Cable Mount, Neutrik TRUE1 NAC3MX-W (male) . . . . . . . . . . . . . . . .P/N 91611788HU

Installation Hardware

Super Lightweight Half Coupler Rigging Clamp, black (suitable for M10 threaded hole). . . .  P/N 91602018
Safety Cable, SWL 60 kg, BGV C1 / DGUV 17, black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 91604006
Safety Cable, SWL 60 kg, BGV C1 / DGUV 17, silver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  P/N 91604007

Содержание Martin DMX PowerPort 375 Series

Страница 1: ...DMX PowerPort 375 User manual...

Страница 2: ...direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Martin is a registered trad...

Страница 3: ...Power and data connections 11 Power input 11 Hybrid power data output 12 Using the product 13 Applying power 13 Status LEDs and control button 13 Handling DMX and RDM 13 Service and maintenance 14 Fus...

Страница 4: ...staller et d utiliser le DMX PowerPort 375 Attention Le DMX PowerPort 375 est con u pour tre int gr avec d autres composants dans une installation de diffusion vid o Suivez les pr cautions d emploi do...

Страница 5: ...5 mm2 cable to connect one unit s mains power THRU connector to the next unit s mains power IN connector you can link a maximum of three 3 DMX PowerPort 375 units total in one chain at 100 120 V or a...

Страница 6: ...ECTION FROM INJURY When installing the DMX PowerPort 375 above ground level ensure that the primary installation hardware and supporting structure can hold at least 10 times the weight of all the devi...

Страница 7: ...own from a truss or it can be mounted on a flat surface For possible system layouts when using the DMX PowerPort 375 with Martin Creative LED Video products please see the user documentation for those...

Страница 8: ...igure 1 Product overview A Short rack mounting ear B Data status LED C Power status LED D Fixture highlight button E DMX IN F DMX THRU G Hybrid DC power and data OUT H Fuseholders I AC mains power IN...

Страница 9: ...screws fasten one of the supplied short rack mounting ears to the other side of the DMX PowerPort 375 as shown in Figure 2 3 Fasten the mounting ears of the DMX PowerPort 375 to the rails in the rack...

Страница 10: ...2 Obtain a rigging clamp and a safety cable that are suitable for the weight of the unit all connected cables etc Suitable items are available from Martin see Accessories on page 18 3 See Figure 5 Usi...

Страница 11: ...ctors see Accessories on page 34 If you need to install a Neutrik powerCON TRUE1 connector on a power cable follow the instructions available on the Neutrik website at www neutrik com The DMX PowerPor...

Страница 12: ...ww martin com et consultez la derni re version du document PowerPort Capacity qui d taille combien d appareils d clairage ou vid o peuvent tre raccord s un PowerPort 375 Lisez attentivement le manuel...

Страница 13: ...cted and operating correctly If you press the button once all connected fixtures will display a constant white pattern If you press the button again all connected fixtures will return to normal Note t...

Страница 14: ...plier for details Fuse replacement Warning Replace fuses with fuses of the same type and rating only Attention Remplacez uniquement les fusibles fondus par des fusibles de m me type et de m me valeur...

Страница 15: ...ng special attention to the air vents in the front panel 3 Wipe the outside of the unit with a cloth lightly moistened in a mild detergent solution Do not splash the unit with water Do not use any pro...

Страница 16: ...ing sent Check DMX controller Internal fault Disconnect from power Do not attempt repairs yourself Contact Martin Service or an authorized Martin service partner for assistance Creative Video fixtures...

Страница 17: ...ly Martin Exterior Dot HP Family Martin VC Grid Family Martin VC Strip Family Martin VC Dot Family via Martin VC Feeder See www martin com for DMX PowerPort 375 Capacity document listing number of fix...

Страница 18: ...1 x Long Rack Mounting Ear incl screws 1 x Coupling Plate incl screws User Manual Please note that a power input cable is not supplied with the product and must be ordered separately see below Accesso...

Страница 19: ...ste Electrical and Electronic Equipment where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements...

Страница 20: ...20 DMX PowerPort 375 User Manual...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...www martin com...

Отзывы: