Soundweb

TM

 London 

BLU-103 

Installation Guide

5054331-A

Содержание BSS Soundweb London BLU-103

Страница 1: ...Soundweb TM London BLU 103 Installation Guide 5054331 A ...

Страница 2: ...tude use do not use this product above 2000m WARNING FOR YOUR PROTECTION READ THE FOLLOWING READ THESE INSTRUCTIONS KEEP THESE INSTRUCTIONS HEED ALL WARNINGS FOLLOW ALL INSTRUCTIONS DO NOT USE THIS APPARATUS NEAR WATER CLEAN ONLY WITH A DRY CLOTH FOR INDOOR USE ONLY DO NOT BLOCK ANY OF THE VENTILATION OPENINGS INSTALL IN ACCORDANCE WITH THE MANUFACTURER S INSTRUCTIONS DO NOT INSTALL NEAR ANY HEAT ...

Страница 3: ...H A POWER CORD WARNING THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A PROTECTIVE EARTHING CONNECTION THE CORES IN THE MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE GREEN AND YELLOW EARTH BLUE NEUTRAL BROWN LIVE AS COLOURS OF THE CORES IN THE MAINS LEAD OF THIS APPLIANCE MAY NOT CORRESPOND WITH THE COLOURED MARKINGS IDENTIFYING THE TERMINALS IN YOUR PLUG PROCEED A...

Страница 4: ...S CONSIGNES CONSERVER CES CONSIGNES RESPECTER TOUS LES AVERTISSEMENTS SUIVRE TOUTES LES CONSIGNES NE PAS UTILISER CET APPAREIL PRÈS DE L EAU NETTOYER UNIQUEMENT AVEC UN CHIFFON SEC POUR USAGE INTÉRIEUR UNIQUEMENT NE PAS OBSTRUER LES OUÏES D AÉRATION EFFECTUER L INSTALLATION CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT NE PAS INSTALLER À PROXIMITÉ DE SOURCES DE CHALEUR TELLES QUE DES RADIATEURS BOUCH...

Страница 5: ...AVEC CORDON D ALIMENTATION FOURNI AVERTISSEMENT CET APPAREIL DOIT ÊTRE BRANCHÉ SUR UNE PRISE SECTEUR DOTÉE D UNE PROTEC TION PAR MISE À LA TERRE LES COULEURS DES NOYAUX DANS LES FILS SECTEURS DOIVENT RESPECTER LES CODES SUIVANTS VERT ET JAUNE TERRE BLEU NEUTRE MARRON PHASE LES COULEURS DES NOYAUX DANS LES FILS SECTEURS DE CET APPAREIL PEUVENT NE PAS CORRESPON DRE AUX INSCRIPTIONS COLORÉES IDENTIFI...

Страница 6: ...V Input Channels Only 2 OH Telephone Channels Only 2 Other Indicators 2 COM Communications 2 STAT Status 2 ERR Error 2 PWR Power 2 Rear Panel 3 AC Mains 3 Locate 3 RS232 3 Ethernet 3 BLU link 3 GPIO Ports 3 VoIP Jack 3 Analogue Input Output Connections 3 Audio Cable Wiring 4 Audio Input Output Wiring Convention 4 Control Inputs 5 2 Wire Mode 5 3 Wire Mode 5 Logic Outputs 6 Opto Output 6 Technical ...

Страница 7: ...eened and connected as follows Audio cable screens to their BLU Device connector ground Control cable screens to the ground screws adjacent to the connector Network cables should be of type Cat 5 or better fitted with a clip on ferrite sleeve STEWART TYPE 28A2029 0A0 near the network socket end This equipment must be earthed It should not be necessary to remove any protective earth or signal cable...

Страница 8: ...Indicates that there is no network control communication and that no Ethernet cable connection is detected or that the unit is still in the process of negotiating its IP address SOLID GREEN Indicates that an Ethernet cable connection is detected and that the unit has established its IP address SOLID YELLOW Indicates that an Ethernet cable connection is detected but an IP address cannot be establis...

Страница 9: ... same audio sample rate GPIO Ports The General Purpose Input and Output GPIO ports can be used to interact with external potentiometers contact closures LEDs and relays See Control Inputs on page 5 Logic Outputs on page 6 and Opto Output on page 6 for further information on these ports VoIP Jack The BLU 103 has two VoIP in out TX RX channels via a VoIP jack This RJ 45 jack allows connection to a s...

Страница 10: ... destination to eliminate ground loop problems This means that the shield S connection on an input is grounded whereas the shield connection on an output is floating although connected via an internal network to ground for EMC compliance Balanced Wiring The convention for balanced wiring 2 core plus shield is shown here Balanced cable Shield Hot Cold Unbalanced Wiring The convention for unbalanced...

Страница 11: ...create contact closure to ground for switches such as mute buttons or resistance to ground for other multi state or continuous controls such as Parameter Presets or faders See the Soundweb London help for a table of resistor values for use with Parameter Presets or source selectors A 47kOhm log potentiometer connected between a control input and common will allow parameters to be controlled linear...

Страница 12: ... LED relay When sourcing from the Logic Output an LED connected between one output Anode A and common Cathode K will illuminate when the logic output is activated without requiring any external current limiting resistor the Soundweb London contains an internal 440 Ohm resistor Port 1 Current source 10mA max LED LD5 For higher current reed type relays you must use the Logic Output to sink current u...

Страница 13: ...ail Length 200 ms Convergence Rate 49 dB s Average convergence rate TELEPHONY Supported Features Two concurrent independent calls Caller ID hold capability redial 16 entry speed dial Adjustable auto answer VoIP Supported Features SIP v2 RFC 3261 and companion RFCs SIP authentication Voice activity detection Dynamic jitter buffer Static DHCP IP address assignment Suported Codecs G 711μ law G 711A l...

Страница 14: ... 41 to 35 95 degrees C degrees F Dimensions HxWxD 1 75 45mm 1U x 19 483mm x 12 5 318mm Weight 9 1 lbs 4 1 kg BSS Audio incorporates high quality mechanical fans in some products All mechanical fans have a limited life expectancy We recommend annual inspection of fans for dust occlusion and excessive noise Fan assemblies should be replaced after six to ten years of use Environmental factors such as...

Страница 15: ......

Страница 16: ...BSS Audio is a registered trademark of Harman 2015 Harman All rights reserved Printed in Malaysia ...