Harman AXYS TUNNEL IndustryAmp Dante PB-400-DN Скачать руководство пользователя страница 17

AXYS

®

 IndustryAmp-DN User Manual Rev 3.0

201911/IAMPDN_3.0

17

The Input Mode setting in WinControl (at 

Input > 

Common parameters

) allow selection of auto-

switching mode. A brief description of each mode follows; 
see the WinControl Help files for full details.

Normal

Auto-switching is disabled. All inputs are active, if more 
than one inputs is selected to go to an output (selected 
using the matrix) then the inputs are summed.

Level-controlled priority switching

When enabled, the inputs will switch when the signal 
level at the detection point drops below -60 dBFS (default 
value), but this threshold may be set to any level between 
-80 dBFS and -20 dBFS. The detection point is either ‘At 
input’ or ‘After processing’. In the latter case filtering may 
be applied, for example to reduce the level of an input 
pilot tone. When using analogue inputs, the relationship 
between dBFS and dBV’s measured at the amplifier’s 
inputs should be taken into consideration; WinControl’s 
Help files give full details.

It is also possible to set a Hold Time, so that unwanted 
switching does not occur between natural gaps in the 
programme.

Pilot tone-controlled priority switching

It is common practice in critical audio systems to permanently 
route a low level, high-frequency tone through the system. 
The presence of this pilot tone can then be detected by various 
items of equipment to verify the continued operation of the 
audio paths. Set Input Mode to Pilot tone-controlled priority 
switching to enable this mode.

The IndustryAmp’s pilot tone detector on the analogue 
inputs operates in the frequency range of approximately 
20 kHz to 28 kHz. The detector is most sensitive in the 
center of this frequency range, the detection threshold is 
not software configurable. On the digital (Dante

) inputs 

the frequency range is 19.2 kHz to 23.5 kHz and the 
threshold may be set between -10 dBFS and -60 dBFS.

The amplifier’s action on non-detection of a pilot tone can 
be configured via WinControl. A fault condition can be 
“flagged”, and/or the input can be set auto-switch to that 
with the next priority.

A notch filter should be inserted to suppress the 

pilot tone if its frequency is less than half the 

internal processor’s sample frequency (F

s

/2,  typically  

24 kHz). If the pilot tone is not sufficiently suppressed, 
signal detection (and other functions such as frost 
protection and Autogain) will not function properly. 
Further, this may result in excessive dissipation in the 
power amplifiers and/or connected loudspeakers, or 
interference with the  internally-generated tone used for load 
monitoring. Pilot tone frequencies above F

s

/2 are sufficiently 

suppressed by the anti-aliasing filter of the ADC. Any pilot tone 
frequency received via the digital inputs is < Fs/2 by default.

Take notice of the following when configuring the parameters for 
the input pilot tone detection:

It is advised to use a few seconds of Grace time in order 
to avoid spurious input pilot tone monitoring errors.

Use a fixed frequency if the frequency of the externally 
applied pilot tone is known and fixed.

See WinControl help file for details.

Failure relay

The single-pole changeover failure relay may be wired to a 
‘common fault’ or other external fault monitoring system 
so that any fault condition detected by the IndustryAmp 
is immediately reported. The conditions which cause 
activation of the failure relay may be defined in WinControl, 
and may include any or all of: DSP/amplifier/Dante

 board 

faults, load monitoring, internal temperature sensing, fan 
operation, pilot tone detection, etc. See the WinControl 
Help files for full details.

If it is required to interface the IndustryAmp to impedance-
sensing fault-monitoring equipment such as the AXYS

® 

Cerberus, the failure relay contacts may be re-configured 
by moving an internal jumper. See “fig.5:  Failure relay” on 
page 14 for connection details
.

Содержание AXYS TUNNEL IndustryAmp Dante PB-400-DN

Страница 1: ...Installation User Manual Applies to Part Numbers TUN 590404 TUN 590804 AXYS IndustryAmp Dante Delivering Clear and Intelligible Messages...

Страница 2: ...ISCLAIMER No part of this manual may be reproduced transmitted transcribed stored in a database system or translated without the express written permission of Harman Professional Documentation kept by...

Страница 3: ...0 Ventilation 10 Connector and Wiring details 11 AC Mains 11 Audio Connections 12 Analogue inputs 12 Amplifier outputs 12 Dante and Control Interface 13 ANS microphone input 13 Failure relay 14 DSP se...

Страница 4: ...receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Unplug this apparatus during lightning storms or when unused for long...

Страница 5: ...analogue inputs plus dual redundant Dante interface 8 x 100W output into 100 ohm load OVERVIEW The AXYS IndustryAmp is a multichannel power amplifier specifically designed for permanent installation i...

Страница 6: ...ge protocol by using the Dante Ethernet interfaces Pilot tone detection ANS Ambient Noise Sensing mic input Surveillance failure relay DSP bypass function Universal power supply 100 240 VAC with activ...

Страница 7: ...mers Load Monitoring Surge Protection Input 1 Out 1 Out 2 Out 3 Out 4 Input 2 Internal Temperature Fan Monitoring Front LED Internal Supplies Mains External Failure Relay Analogue Pilot detect Digital...

Страница 8: ...ut connections may be made The detector will when enabled switch from Input 1 to Input 2 if pilot tone is lost The IndustryAmp incorporates surveillance functions which activate an externally accessib...

Страница 9: ...2 13 14 Wiring details for all the rear connectors can be found in subsequent sections of the manual Not present on PB 400 DN 2 Failure relay connector 3 ANS microphone input 4 Analogue input 1 5 Anal...

Страница 10: ...ontaining a significant quantity of other heat generating equipment see below consideration should be given to climate controlling the room in which the equipment rack is situated Do not install the I...

Страница 11: ...gate why it blew Always replace by a fuse of the same type and rating as indicated on the rear panel and or in the amplifier datasheet NOTE The PowerCon connector should NEVER be plugged in or unplugg...

Страница 12: ...IndustryAmp should always be used wherever possible If driving from an unbalanced source use the same wiring as shown above at the amplifier end but connect the hot core to the signal output and the...

Страница 13: ...increase the distance further A third party Ethernet to fibre interface will be required in these situations The Dante interfaces add digital audio I O and a control method to the IndustryAmp They pr...

Страница 14: ...oving an internal PCB jumper See fig 5 Failure relay In volt free operation CO is connected to NC a failure condition causes CO to be connected to NO When configured for impedance sensing use the impe...

Страница 15: ...Dante xmt 12 Dante xmt 13 Dante xmt 14 Dante xmt 15 Dante xmt 16 Dante xmt 17 Dante xmt 1 Dante xmt 2 Dante xmt 3 Dante xmt 4 Dante xmt 5 Dante xmt 6 Dante xmt 7 Dante xmt 8 To Dante Outputs Dante xmt...

Страница 16: ...han one input is selected to go to the same output then the inputs are summed Autogain The DSP section includes an autogain algorithm which can be set to automatically adjust the overall volume level...

Страница 17: ...to 23 5 kHz and the threshold may be set between 10 dBFS and 60 dBFS The amplifier s action on non detection of a pilot tone can be configured via WinControl A fault condition can be flagged and or th...

Страница 18: ...brated with the normal loads connected to each amplifier channel to establish a reference load current After calibration any partial or total failure of any of the loads or cabling will be registered...

Страница 19: ...of the chassis to ground Always connect this terminal 2 Reduction of RF emission Although the IndustryAmp electronics are well shielded and external connections are decoupled to prevent RF emission fr...

Страница 20: ...www axystunnel com...

Отзывы: