QUICK START GUIDE
NXB-CCG
NetLinx
®
Clear Connect™ Gateway (434 MHz - US/Canada Only)
Overview
The NXB-CCG NetLinx Clear Connect Wireless Gateway (
FG2606
) connects NetLinx
Controllers with Lutron's Clear Connect Dimmers, Switches, Occupancy/Vacancy
Sensors and Keypads. The Gateway includes a web interface for simplified integration,
configuration, and programming of Clear Connect devices. When integrated with an
AMX NetLinx Controller, installers now have a simple and cost-effective path to offer
smart room automation that includes light and AV control from a single interface,
occupancy sensing, scheduled shutdown and energy management.
Product Specifications
FCC/ IC Information
This device complies with part 15 of the FCC Rules and Industry Canada license-exempt
RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) this device must accept any interference, including interference that may
cause undesired operation. Modifications not expressly approved by Lutron
Electronics Co., Inc. could void the user's authority to operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
Proper orientation of the antenna helps ensure maximum range and the best
performance. The NXB-CCG should be positioned centrally to the devices being
controlled, and as high and clear of obstructions as possible. The NXB-CCG utilizes an
omni-directional antenna, which produces a circular pattern perpendicular to the
antenna. For best performance, the antenna should be positioned vertically (tip up or
down, not sideways). Try to keep the antenna at least 2 feet from metallic objects.
Important Notes
Codes: Install in accordance with all local and national electrical codes.
Cleaning: To clean, wipe with a clean damp cloth. DO NOT use any chemical cleaning
solutions.
WARNING: Using a DC adapter not rated at the proper specifications could damage the
NXB-CCG and possibly overheat the DC adapter. Use only the Lutron DC adapter listed
above.
RF Device Placement: All dimmers, switches, keypads and shades / draperies must be
located within 30 ft (9 m) of the NXB-CCG (FIG. 2).
FIG. 1
NXB-CCG CLEARCONNECT WIRELESS GATEWAY
NXB-CCG SPECIFICATIONS
Power Requirements:
•
Power Consumption:
600mA @ 5VDC, DC adapter included
(5V DC, 2A).
•
Surge Protection:
To withstand surge voltages without
damage or loss of operation, in accordance with
IEEE C62.41-1991 Recommended Practice on Surge Voltages
in Low-Voltage AC Power Circuits.
•
Power Failure Memory:
Should power be interrupted, the
NXB-CCG will return to its previous state when power is
restored.
Front Panel Components:
Power/Status LED:
Displays power status and other system status indicators.
RF LED:
Displays the Tx / Rx activity on the RF link.
Ethernet LED:
Displays the connection status and Tx / Rx activity on the
Ethernet link.
Rear Panel Components:
CAT5 Cable Port:
Maximum cable length: 328 ft (100 m)
USB Cable Port:
Manufacturer use only.
Reset Button:
Press and hold for 20 seconds to restore the system to the
Factory Default settings.
Power Jack (to DC
adapter)
(IEC PELV / NECR Class 2). To be connected to a class 2 power
source only.
Operating Environment:
• 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-
condensing.
• Indoor use only.
ESD Protection:
ESD protection to withstand electrostatic discharge without
damage or memory loss, in accordance with IEC 61000-4-2.
Communications:
• The NXB-CCG communicates to other Clear Connect devices
through RF.
• All devices (except wired accessory dimmers/switches) must
be located within 30 feet (9 m) of the NXB-CCG.
Auto Discovery:
Supports the ZeroConf auto discovery protocol.
Antenna
Power/Status LED
RF LED
Ethernet LED
Reset
CAT5 Cable
Port
USB Cable
Port
Button
5VDC Power
Jack
1 1/8”
(2.86 cm)
2.58”
(6.60 cm)
NXB-CCG SPECIFICATIONS (CONT.)
Dimensions (HWD):
• Without antenna: 1 1/8” x 2 5/8” x 4 7/16”
(2.86 cm x 6.60 cm x 11.23 cm)
• With antenna: 6 1/2” x 2 5/8” x 4 7/16”
(17.15 cm x 6.60 mm x 112.27 mm)
Weight:
0.3 lbs (136.08 g)
Certifications:
• FCC FCC Title 47 Part 15 Subpart B and C
• IC
• cULus UL 60950-1
Included Accessories:
• 5VDC Adapter (
WA-10J05FU
)
• CAT5 Suppression Ferrite
Other AMX Equipment:
• CCD3-OCRB-P-WH, 868 MHz Ceiling Mount Occupancy/
Vacancy Sensor (
FG2606-44-WH
)
• PS-CCG 5 VDC, 3A Power Supply With 2.1mm Barrel
Connector (
FG423-61
)
FIG. 2
RF CONFIGURATION
30 feet (9 m) maximum
NXB-CCG
Power Source
Lutron switches/dimmers
Note: Antenna
position for clarity
only. Antenna should
always be installed
upright.