The NXB-CCG NetLinx Clear Connect Wireless Gateway (

FG2606

) connects NetLinx 

Controllers with Lutron's Clear Connect Dimmers, Switches, Occupancy/Vacancy 

Sensors and Keypads. The Gateway includes a web interface for simplified integration, 

configuration, and programming of Clear Connect devices. When integrated with an 

AMX NetLinx Controller, installers now have a simple and cost-effective path to offer 

smart room automation that includes light and AV control from a single interface, 

occupancy sensing, scheduled shutdown and energy management.

Product Specifications  

FCC/ IC Information

This device complies with part 15 of the FCC Rules and Industry Canada license-exempt 

RSS standard(s). Operation is subject to the following two conditions:

(1) This device may not cause interference, and

(2) this device must accept any interference, including interference that may 

cause undesired operation. Modifications not expressly approved by Lutron 

Electronics Co., Inc. could void the user's authority to operate this equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B 

digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a residential installation. This 

equipment generates, uses and can radiate radio frequency energy and, if not installed 

and used in accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will not occur in a 

particular installation. If this equipment does cause harmful interference to radio or 

television reception, which can be determined by turning the equipment off and on, the 

user is encouraged to try to correct the interference by one or more of the following 

measures:

• Reorient or relocate the receiving antenna

• Increase the separation between the equipment and receiver

• Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected

• Consult the dealer or an experienced radio/TV technician for help

Proper orientation of the antenna helps ensure maximum range and the best 

performance. The NXB-CCG should be positioned centrally to the devices being 

controlled, and as high and clear of obstructions as possible. The NXB-CCG utilizes an 

omni-directional antenna, which produces a circular pattern perpendicular to the 

antenna. For best performance, the antenna should be positioned vertically (tip up or 

down, not sideways). Try to keep the antenna at least 2 feet from metallic objects.

Important Notes

Codes: Install in accordance with all local and national electrical codes.
Cleaning: To clean, wipe with a clean damp cloth. DO NOT use any chemical cleaning 

solutions.

WARNING: Using a DC adapter not rated at the proper specifications could damage the 

NXB-CCG and possibly overheat the DC adapter. Use only the Lutron DC adapter listed 

above.

RF Device Placement: All dimmers, switches, keypads and shades / draperies must be 

located within 30 ft (9 m) of the NXB-CCG (FIG. 2).

FIG. 1  

NXB-CCG CLEARCONNECT WIRELESS GATEWAY

NXB-CCG SPECIFICATIONS

Power Requirements:

Power Consumption:

 600mA @ 5VDC, DC adapter included 

(5V DC, 2A).

Surge Protection:

 To withstand surge voltages without 

damage or loss of operation, in accordance with 

IEEE C62.41-1991 Recommended Practice on Surge Voltages 

in Low-Voltage AC Power Circuits.

Power Failure Memory:

 Should power be interrupted, the 

NXB-CCG will return to its previous state when power is 

restored.

Front Panel Components:

Power/Status LED:

Displays power status and other system status indicators.

RF LED:

Displays the Tx / Rx activity on the RF link.

Ethernet LED:

Displays the connection status and Tx / Rx activity on the 

Ethernet link.

Rear Panel Components:

CAT5 Cable Port:

Maximum cable length: 328 ft (100 m)

USB Cable Port:

Manufacturer use only.

Reset Button:

Press and hold for 20 seconds to restore the system to the 

Factory Default settings.

Power Jack (to DC 

adapter)

(IEC PELV / NECR Class 2). To be connected to a class 2 power 

source only.

Operating Environment:

• 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-

condensing. 

• Indoor use only.

ESD Protection:

ESD protection to withstand electrostatic discharge without 

damage or memory loss, in accordance with IEC 61000-4-2.

Communications:

• The NXB-CCG communicates to other Clear Connect devices 

through RF.

• All devices (except wired accessory dimmers/switches) must 

be located within 30 feet (9 m) of the NXB-CCG.

Auto Discovery:

Supports the ZeroConf auto discovery protocol.

Antenna

Power/Status LED

RF LED

Ethernet LED

Reset

CAT5 Cable

Port

USB Cable

Port

Button

5VDC Power

Jack

1 1/8”

(2.86 cm)

2.58”

(6.60 cm)

NXB-CCG SPECIFICATIONS (CONT.)

Dimensions (HWD):

• Without antenna: 1 1/8” x 2 5/8” x 4 7/16” 

(2.86 cm x 6.60 cm x 11.23 cm)

• With antenna: 6 1/2” x 2 5/8” x 4 7/16” 

(17.15 cm x 6.60 mm x 112.27 mm)

Weight:

0.3 lbs (136.08 g)

Certifications:

• FCC FCC Title 47 Part 15 Subpart B and C

• IC

• cULus UL 60950-1

Included Accessories: 

• 5VDC Adapter (

WA-10J05FU

)

• CAT5 Suppression Ferrite

Other AMX Equipment:

• CCD3-OCRB-P-WH, 868 MHz Ceiling Mount Occupancy/

Vacancy Sensor (

FG2606-44-WH

)

• PS-CCG 5 VDC, 3A Power Supply With 2.1mm Barrel 

Connector (

FG423-61

)

FIG. 2  

RF CONFIGURATION

30 feet (9 m) maximum

NXB-CCG

Power Source

Lutron switches/dimmers

Note: Antenna 

position for clarity

only. Antenna should

always be installed

upright.