Harman AMX MODERO S MST-1001 Скачать руководство пользователя страница 38

Troubleshooting

38

Modero S Series G4 Touch Panels - Installation & Hardware Reference Manual

Troubleshooting

Overview

This section describes the solutions to possible hardware/firmware issues that could arise during the common operation of a 

Modero S touch panel.

Panel Doesn’t Respond to Touches

Symptom: 

The device either does not respond to touches on the touch screen or does not register the touch as being in the correct 

area of the screen.
If the screen is off:



The device may be in Display Sleep Mode. 

Press and hold the 

Sleep

 button with a pointed instrument to wake up the panel.



The device may not be connected to power.

 Verify that the power source is connected to the device and receiving power.

Panel Isn’t Appearing in the Online Tree Tab

1.

Verify that the System number is the same on both the NetLinx Project Navigator window and the System Settings page on the 

device.

2.

Verify the proper NetLinx Master IP and connection methods entered into the Master Connection section of the 

System 

Settings

 page.

Can’t Connect to a NetLinx Master

Symptom: 

I can’t seem to connect to a NetLinx Master using NetLinx Studio.

Select 

Settings > Master Comm Settings > Communication Settings > Settings (for TCP/IP)

, and uncheck the "Automatically Ping 

the Master Controller to ensure availability". 
The pinging is to determine if the Master is available and to reply with a connection failure instantly if it is not. Without using the 

ping feature, a connection may still be attempted, but a failure will take longer to be recognized. 

NOTE: 

If you are trying to connect to a Master controller that is behind a firewall, you may have to uncheck this option. Most firewalls 

will not allow ping requests to pass through for security reasons.

When connecting to a NetLinx Master controller via TCP/IP, the program will first try to ping the controller before attempting a 

connection. Pinging a device is relatively fast and will determine if the device is off-line, or if the TCP/IP address that was entered 

was incorrect.
If you decide not to ping for availability and the controller is off-line, or you have an incorrect TCP/IP address, the program will try 

for 30-45 seconds to establish a connection.

Only One Modero S Series Panel Indicated in My System

Symptom: 

I have more than one Modero S Series panel connected to my System Master and only one is indicated.

Multiple NetLinx Compatible devices can be associated for use with a single Master. If the user does not assign a device number, 

one will be assigned automatically to the panel. When using multiple panels, different Device Number values have to be assigned to 

each panel.
1.

Press and hold the 

Sleep

 button with a pointed instrument to open the 

Settings

 page.

2.

Press the 

Protected b

utton, enter 

1988

 into the on-screen Keypad’s password field, and press 

Done

 when finished. 

3.

Enter a Device Number value for the panel into the Device Number Keypad. The range is from 1 - 32000. 

Содержание AMX MODERO S MST-1001

Страница 1: ...OP TOUCH PANEL MSD 1001 L 2 10 1 MODERO S SERIES LANDSCAPE WALL MOUNT TOUCH PANEL MST 701 7 MODERO S SERIES TABLETOP TOUCH PANEL MSD 701 L 2 7 MODERO S SERIES LANDSCAPE WALL MOUNT TOUCH PANEL MST 431...

Страница 2: ...es and the point where they exit from the apparatus 11 ONLY USE attachments accessories specified by the manufacturer 12 USE ONLY with a cart stand tripod bracket or table specified by the manufacture...

Страница 3: ...ween the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for he...

Страница 4: ...pect Ratio 9 Cleaning the Touch Overlay and Case 9 MST D 1001 10 1 S Series Touch Panels 10 MST 1001 Tabletop 10 MST 1001 Specifications 10 MSD 1001 L 2 Wall Mount Landscape 12 MSD 1001 L 2 Specificat...

Страница 5: ...kbox 32 UPPER TABS FIRST 32 LOWER TABS Gently Snap Into Place 32 Removing the MSD 1001 L 2 from the Backbox 33 Upgrading Firmware 34 Overview 34 Downloading Firmware Updates From www amx com 34 Upgrad...

Страница 6: ...access the Setup pages The Sleep button is located on the top left edge of the frame when facing the panel see FIG 2 The Sleep Button s Functions are described below FIG 1 Modero S Series Touch Panel...

Страница 7: ...seconds of these dots appearing on the screen Using the Settings Pages When opened the Settings menu appears in the center of the panel display Note that many of the pages may be longer than they init...

Страница 8: ...y the last one uploaded to date 5 On the rightmost red button select the number of seconds a selected image will be displayed in Picture View This may be selected between 5 10 15 30 and 60 seconds 6 T...

Страница 9: ...on was improperly set and you cannot return to the Calibrate page through the panel s firmware this firmware page can be accessed via G4 WebControl by navigating to the Protected Setup page and pressi...

Страница 10: ...178 63 CERTIFICATIONS FCC Part 15 Class B CE EN 55022 55024 C Tick CISPR 22 Class B IEC EN UL 60950 1 CISPR 22 Class B RoHS WEEE TOUCH SCREEN DISPLAY Display Type TFT Active Matrix Color LCD Display S...

Страница 11: ...raphics and image processing capability on a variety of AMX Touch Panels and other devices see TPD4 Operations Guide for more information EMBEDDED APPLICATIONS Remote Management VNC Server G4 Web Cont...

Страница 12: ...mm x 50 50mm Note See FIG 9 on page 14 for details WEIGHT 1 95 lbs 885 Kg with Backbox 1 5 lbs 680 Kg without Backbox POWER CONSUMPTION Full On 14W Typical 7 5W Standby 4 7W Shutdown 0 8W Start Up Inr...

Страница 13: ...at 25 fps decode Supported Video Transport Streams MPEG TS for MPEG2 and H 264 HTTP for MJPEG Max Number of Active Video Streams One decode AUDIO Microphone 42 dB 3 dB sensitivity FET microphone Spea...

Страница 14: ...ro S Series Wall Mount Touch Panel FG2265 14 MSA AMK 10 Any Mount Kit for use with MSD 1001 FG2265 26 MSA AMK2 10 Any Mount Kit for use with MSD 1001 L2 RMBK 1001 FG2265 36 MXA MP Modero X S Series Mu...

Страница 15: ...FICATIONS FCC Part 15 Class B CE EN 55022 55024 C Tick CISPR 22 Class B IEC EN UL 60950 1 CISPR 22 Class B RoHS WEEE TOUCH SCREEN DISPLAY Display Type TFT Active Matrix Color LCD with Fringe Field Swi...

Страница 16: ...ngine the driving force behind the advanced graphics and image processing capability on a variety of AMX Touch Panels and other devices see TPD4 Operations Guide for more information EMBEDDED APPLICAT...

Страница 17: ...with backbox HWD 4 88 x 7 38 x 1 99 123 91mm x 187 51mm x 50 50mm See FIG 13 on page 19 for details WEIGHT 1 05 lbs 680 Kg with Backbox 0 8 lbs 363 Kg without Backbox POWER CONSUMPTION Full On 11W Ty...

Страница 18: ...ps decode MJPEG up to 720p at 25 fps decode only Supported Video Transport Streams MPEG TS for MPEG2 and H 264 HTTP for MJPEG Max Number of Active Video Streams One decode AUDIO Microphone 42 dB 3 dB...

Страница 19: ...abit PoE Ethernet Switch FG2178 63 MXA BT Bluetooth USB Adapter for Modero X S Series Touch Panels FG5968 19 MXA HST Bluetooth Handset for Modero X S Series Touch Panels FG5968 17 CB MXSA 07 Rough In...

Страница 20: ...TIONS FCC Part 15 Class B CE EN 55022 55024 C Tick CISPR 22 Class B IEC EN UL 60950 1 CISPR 22 Class B RoHS WEEE TOUCH SCREEN DISPLAY Display Type TFT Active Matrix Color LCD Display Size WH Landscape...

Страница 21: ...Operations Guide for more information EMBEDDED APPLICATIONS Remote Management VNC Server G4 Web Control AMX Resource Management Suite Video Conferencing Panel to panel and video chat the MST 431 recei...

Страница 22: ...iews MSD 431 L Specifications DIMENSIONS with backbox HWD 3 415 x 5 045 x 2 000 86 75mm x 128 14mm x 50 80mm See FIG 17 on page 24 for details WEIGHT 0 65 lbs 295 Kg with Backbox 0 5 lbs 225 Kg withou...

Страница 23: ...icrophone 42 dB 3 dB sensitivity FET microphone Speakers 4 ohm 1 5 Watt 500 Hz cutoff frequency Supported Audio Codecs MP2 Layer I and II MP3 8 kHz 11 025 kHz 12 kHz 16 kHz 22 05 kHz 24 kHz 32 kHz 44...

Страница 24: ...ew FG5968 20 MXA MPL Modero X S Series Multi Preview Live FG5968 10 PS POE AF TC PoE Injector 802 3AF Compliant FG423 83 NXA ENET8 2POE Gigabit PoE Ethernet Switch FG2178 63 MXA BT Bluetooth USB Adapt...

Страница 25: ...ions USB peripherals mouse keyboard etc may be connected to the USB port on the rear of the device Updates to the device s firmware can also made via the USB port Note that FIG 18 shows a MST 1001 but...

Страница 26: ...must be taken into consideration to maintain the product within the specified operating temperature FIG 19 shows an AMX device installed in a wall with a filled volume such as with insulation or concr...

Страница 27: ...MXSA 07 10 Rough In Boxes Refer to the Quick Start Guide included with each mounting kit for instructions Plastic Backbox S Series wall mount panels comes with a clear plastic Backbox This Backbox ca...

Страница 28: ...allows you to troubleshoot possible conflicts with wall edges doors and other potential obstacles The S Series installation templates are shown in FIG 24 NOTE Prepare the area by removing any screws o...

Страница 29: ...or each S Series panel is indicated below NOTE Consider making the actual cutout opening slightly smaller than the provided dimensions This provides a margin of error if the opening needs to be expand...

Страница 30: ...surface This Backbox uses two Locking Tabs to secure the Backbox to the wall For typical mounting surfaces such as drywall the locking tabs are the primary method for securing the Backbox to the wall...

Страница 31: ...STEP 2 Insert Connectors on the Touch Panel 1 Before installing the touch panel into the Backbox connect the Ethernet and USB cables to the rear of the panel 2 Remove power at the terminal end before...

Страница 32: ...down the panel stop and verify there are no cables in the way Do not force the panel into position or the touch screen or the panel electronics may be damaged 2 Gently press the bottom edge of the pa...

Страница 33: ...nd to stabilize the front of the touch panel Always pull on the panel s plastic bezel NEVER pull on the glass edge FIG 34 3 With the bottom edge of the panel free carefully lift up and out to release...

Страница 34: ...tion Upgrading Firmware via USB Flash Drive Firmware and TPDesign4 files may be transferred to the panel made via USB flash drive Load the Firmware on a USB Flash Drive 1 Insert the USB flash drive in...

Страница 35: ...e Upgrading from Previous Firmware S Series panels provide the option to revert the device to the previous firmware run before an upgrade To upgrade the device from previously loaded firmware 1 From t...

Страница 36: ...efer to the device page for firmware updates Transferring the KIT File via NetLinx Studio 1 In Netlinx Studio right click in the Online Tree tab of the Workspace window and select Refresh System Onlin...

Страница 37: ...that the Reboot Device option is selected It is necessary to reboot the panel after a firmware upgrade 3 Click Send to begin the file transfer 4 The progress of the transfer operation is indicated in...

Страница 38: ...ith a connection failure instantly if it is not Without using the ping feature a connection may still be attempted but a failure will take longer to be recognized NOTE If you are trying to connect to...

Страница 39: ...ot assume responsibility for errors or omissions AMX also reserves the right to alter specifications without prior notice at any time The AMX Warranty and Return Policy and related documents can be vi...

Отзывы: