Harman AMX AXB-DMX512 Скачать руководство пользователя страница 1

QUICK START GUIDE

AXB-DMX512 

DMX512 Interface

Overview

The AXB-DMX512 creates a bi-directional DMX512-to-AxLink connection, transmitting 

and receiving up to 512 DMX channels. On-board processing and memory create as 

many as 96 channel groups, eight faders, and 72 presets (284 by adding extended 

memory), as well as soft-patch channels. A DMX lighting board can operate in tandem 

with the AXB-DMX512, generate levels for storing presets, or bypass the AXB-DMX512 

for direct control of channels.

Specifications

Setting the Device DIP Switch

The 8-position DEVICE DIP switch on the front panel (FIG. 1) sets the AxLink 

identification number for the AXB-DMX512. Make sure the device number matches the 

number assigned in the Axcess software program.
The following table describes the values on the DEVICE DIP switch. 

Terminating the Device

When using the DMX input and if this device is the last device in a chain of DMX512 

devices, you must terminate the line. To terminate the device, position jumpers on 

jumper pin trios JP4 and JP5 (FIG. 2):

1.

Remove the jumper that is on pins 1 and 2 of jumper trios JP4 and JP5. (Pins 1 

and 2 are marked HIZ - see FIG. 3).

2.

Place the jumper on pins 2 and 3 of jumper trios JP4 and JP5. (Pins 2 and 3 are 

marked TERM -see FIG. 3). This terminates the incoming DMX input with a 120 

ohm resistor.

Wiring Devices to the AXB-DMX512

The AXB-DMX512 has three captive-wire connectors on the rear panel (FIG. 4) for 

DMX512 transmit and receive, and AxLink.

Preparing/Connecting Captive Wires

1.

Strip 0.25 inch of wire insulation off all wires.

2.

Insert each wire into the appropriate opening on the connector according to the 

wiring diagrams and connector types described in this section. Do not tighten the 

screws excessively; doing so may strip the threads and damage the connector.

Wiring Guidelines

The interface requires a 12 VDC power to operate properly. The Central Controller 

supplies power via the AxLink cable or external 12 VDC power supply. The maximum 

wiring distance between the Central Controller and interface is determined by power 

consumption, supplied voltage, and the wire gauge used for the cable. 

FIG. 1  

AXB-DMX512 (FRONT VIEW)

AXB-DMX512 SPECIFICATIONS

Power consumption 160 mA @ 12 VDC
Power supply

12 VDC

Front panel components:

LED Indicators

• AXlink LED (green and blinks to indicate AXlink communication 

activity and power:

Full-Off

   indicates no power is being received or the controller is 

not functioning properly.

One blink per second

   indicates power is active and AXlink 

communication is functioning.

Full-On

   indicates there is no AXlink control or activity, but power is 

On.

• RX LED (red) indicates the AXB-DMX512 is receiving DMX512 data. 

Corresponds to the IN and OUT ports on the rear panel.

• TX LED (red) indicates the AXB-DMX512 is transmitting DMX512 

data. Corresponds to the IN and OUT ports on the rear panel.

DIP switch

• 8-position DEVICE DIP switch sets the AxLink address (Device ID) 

for the AXB-DMX512.

• The DIP Switch to the right of the DEVICE DIP is reserved - no 

settings are required.

Rear panel components:

DMXIN port

5-wire, captive-wire connector for receiving data.

DMXOUT port

5-wire, captive-wire connector for transmitting data.

AXlink

4-wire, captive-wire connector for data and power.

Dimensions (HWD)

1.5" x 5.5" x 5.5" (38 mm x 140 mm x 140 mm)

Enclosure

Metal with black matte finish

Mounting

Rack mounting with the optional AC-RK Accessory Rack Kit

Weight

1.1 lb (0.5 kg)

DEVICE DIP SWITCH SETTINGS

Position

1

2

3

4

5

6

7

8

Value

1

2

4

8

16

32

64

128

AXlink

DEVICE

ON

RX

TX

Device ID DIP Switch

AxLink activity LED

DMX512 (Transmit) LED

DMX512 (Receive) LED

FIG. 2  

LOCATION OF TERMINATION JUMPERS (JP4-JP5)

FIG. 3  

TERMINATION JUMPER PIN SETTINGS FOR JP4 AND JP5

FIG. 4  

AXB-DMX512 (REAR VIEW)

COR

JP5

JP4

front

Termination Jumpers 

(JP4 / JP5)

DEVICE DIP Switch

The DIP Switch located to the 

right of the DEVICE DIP switch 

is not used - no settings are 

required, and any setting 

will work.

TERM

HIZ

IN

OUT

AXlink

DAT

A

GND

GND

DAT

A

DAT

A

DAT

A

NC

DAT

A

DAT

A

DAT

A

DAT

A

NC

GND

AXP

AXM

PWR

1

2

1

2

1

1

2

2

Отзывы: