Accentra 52i Wood Fireplace ZC Kit

Instructions - 

Part #1-00-574205

Installation into a Zero Clearance Wood Fireplace

Contents:

(1) HWH TEK 10 x 3/4 - 3-30-511007517

(1) Modification label - 1601246

When installing the Accentra 52i into a factory built wood 

burning  fireplace,  several  things  need  to  be  taken  into 

consideration.
The size of the fireplace opening. Will the unit fit into the 

opening?  Some  of  the  factory  built  fireplaces  have  metal 

smoke shields inside the top that can be removed to gain 

height. Keep in mind that anything removed from the factory 

built fireplace must be attached to the fireplace with a metal 

wire. 

Floor protection guidelines, as listed previously, must 

also be followed.  
The manufactured fireplace may not be altered beyond the 

exceptions listed below. Never remove masonry bricks or 

mortar from an existing fireplace.

The following modifications are permissible:

• 

Removal of the damper or lock in open position

• 

Removal of smoke shelf or baffle

• 

Removal of andirons or ember catchers

• 

Removal of log grate

• 

Removal of view screen or curtain

• 

Removal of doors

• 

External trim pieces, that do not affect the operation of 

the fireplace,  may be  removed  providing  they can  be 

stored on or within the fireplace for reassembly if the 

insert is removed.

• 

If the hearth extension is lower than the fireplace opening, 

the portion of the insert extending onto the hearth must 

be supported.

• 

Final approval of this type of installation is contingent 

upon the authority having jurisdiction.

• 

If any of the modifications detailed above are completed 

on the fireplace during installation, the label included in 

this kit, part number 1601246 must be installed. 

The factory built chimney must be listed per UL 127 (US) 

and meet type HT requirements of UL 103 (US).  Factory 

Built fireplace chimneys tested to UL 127-98 may be, at the 

fireplace manufacturers option, tested to the same criteria 

as UL 103HT requirements.  If the chimney is not listed as 

meeting HT requirements, or if the factory built fireplace was 

tested prior to 1998, a full height listed chimney liner must be 

installed from the appliance flue collar to the chimney top.  

Liner  must  meet  high  temperature  (2100°  F)  per  UL1777 

(US).  The liner must be securely attached to both the flue 

collar and the chimney cap. To prevent room air passage to 

the chimney cavity of the fireplace, seal the damper area 

around the chimney liner with fiberglass batting.

* Floor protection must be used from hearth opening to 6” (152mm) 

in front of door glass and 6” (152mm) to each side of the stove body 

OR 8” (203mm) to sides and 18” (457mm) in front (CANADA) to 

protect combustibles from hot ashes. A minimum size will be 16.5” 

deep by 30” wide and be made of a non-combustible material or 

meet UL approval.

A = to sidewall
B = to 12" mantel
C = to 3/4" trim
D = to 3/4" trim
E = floor protection

12” (305mm) Mantel

B

A

E

E

C

D

Clearances:

A

B

*C *D E

 (From Glass)

From Insert 

Body:

12” 

(305mm)

12” 

(305mm) 0” 0”

6”

(152mm)

*3/4” trim, zero clearance to cast surround

18”

(457mm Canada)