The harman TlC 2000 Coal/wood Stove

Installation & Operating manual

R11

manual # 3-90-08691

Содержание TLC 2000 Stove

Страница 1: ... FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authority such as municipal building department fire department fire prevention bureau etc to determine the need for a permit Cette guide d utilisation est disponible en francais Chez votre concessionnaire de Harman sav...

Страница 2: ......

Страница 3: ... utilisation avec le bois solide comme une Cheminée ou un charbon alimentent seulement Le Canada Le charbon et ou le bois où les codes locaux permettent AVERTISSEMENT L Utilisation d Autre Combustible n Est pas Permise Si l appareil ou le raccord de cheminée rougit c est que le feu est trop puissant Pour ventiateur en option no 1 00 08643 Seulemente Éloignez le cordon électrique de l appareil DANG...

Страница 4: ...SE INSTRUCTIONS Harman 352 Mountain House Road Halifax PA 17032 U S A INDEX Specifications 6 Operation 8 Building a Fire 9 Maintenance 13 Installation 15 Chimney System 17 Service Parts List 20 Warranty 23 Note This appliance is also approved for installation into a shop Appliance Certification Model TLC 2000 Listed By OMNI Test Laboratories Report 135 S 28 4 Type Solid Fuel Burning Room Heater St...

Страница 5: ... are closed and latched 3 Check stove for normal operation 4 Check for false alarm 5 Have all occupants exit the building until the cause for the alarm is discovered and or remedied Neverusegasoline gasoline typelantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this heater Keep all such liquids wellaway from the heater while it is in use do not instal...

Страница 6: ...lbs Flue Size 6 inch Fuel USA Pea Nut or Stove coal Cordwood with optional spark screen Canada Wood or coal as above Wood alone as local codes allow Log Length Recommended 16 with 18 Max Heating Capacity 1 900 sq ft Blower Size optional 135 cfm variable speed ...

Страница 7: ...ove 7 Top Load Door Top Load Door Arm Side Shield Ash Door Latch Ash Door Coal Air Control Front Load Door Latch Top Load Opening Glass Door Grates 2 Wood Air Control Removable Shaker Handle Clean out Cover Coal Bars 3 ...

Страница 8: ...sists of two Cast iron grates linked together to operate simultaneously when the external shaker handle is moved The purpose of the grate system is to support the coal bed while air flows up through the grates to the burning coal The grates are also used to remove ashes from the bottom of the coal bed while the fire is burning This is accomplished by shaking the shaker lever back and forth with sh...

Страница 9: ... and Maintaining a Wood Fire Never use gasoline gasoline type lantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this heater Keep all such liquids well away from the heater while it is in use Crumple up six to eight sheets of news paper and place in the firebox Next place pieces of dry wood 3 4 inch maxi mum diameter on top of the paper Next place seve...

Страница 10: ...lly by shaking the grates Wood burns best with an ash bed under the wood therefore do not shake all of the ashes down Never let the ashes build up to over 3 in depth Excessive ash buildup can prevent proper venting of exhaust gases Also do not overfill the ash pan Ash buildup between the ash pan and the grates can cause them to overheat and wear out prematurely Operating as a Fireplace The TLC 200...

Страница 11: ...ing Avoid overfiring your stove This is a potentially hazardous situation which can lead to the overheating of combustible wall or floor materials damage to the stove and in extreme cases cause a fire Overfiring is caused by Too much air flowing through the stove too quickly You may have inad vertently left the bottom door open Or Not keeping up with routine maintenance such as checking door gaske...

Страница 12: ...ng it to the right Allow the fire to burn vigorously for several minutes Shake the grates with short choppy strokes until the first red coals fall into the ash pan then stop Add coal to the top of the coal bed It is good to allow some red hot coals ex posed to help ignite the gases coming off of the newly added coal These gases can be volatile if left accumulate The coal air control may be returne...

Страница 13: ...osote build up has occurred If a significant layer of creosote has accumulated 3mm or more it must be removed to reduce the risk of a chimney fire In the event of a chimney fire call your local fire department make sure everyone is safely out of the house Reduce the air intake of the stove as much as possible using the air control lever Do not throw water on the fire this can cause stove damage an...

Страница 14: ...ass while it is hot and do not use abra sive substances Wash the surface with cool water and rinse thoroughly You may wish to use a non abrasive cleaner specifically designed for use on stove glass In any case dry thoroughly before relighting your stove Gaskets Gaskets are used on the doors and top lid of the TLC 2000 You must check these gaskets from time to time and replace them when necessary T...

Страница 15: ...d of coals is established you can run the blower at any speed desired The power cord for the blower must be connected to a grounded outlet and must be routed away from the appliance Blower Variable Speed knob Top Air Grill Optional The top air grill must be installed before the chimney con nector is installed To install simply place the top air grill over the flue out let and position as shown at ...

Страница 16: ...hose presented here Parallel versus Corner Installations Aparallel installation is one in which the back and sides of the stove are parallel to the walls behind and to the side of the stove Acorner installation is one in which the back of the stove is positioned diagonally across a corner of the room Each installation requires its own set of clearances For parallel installations the required clear...

Страница 17: ...n be caused by a very tall chimney even if it is the recom mended size and can cause overfiring of your stove Signs of an overdraft include rapid fuel consumption inability to slow the fire and parts of the stove or chimney connector glowing red It is important that you follow the chimney guidelines in this manual including size type and height to avoid draft problems When installed and operated a...

Страница 18: ...um recommended height for any chimney is 16 ft 4 8 m above flue collar height A round flue either masonry or approved prefabricated of either 6 150 mm 7 180 mm or 8 200 mm may be used For square or rectangular masonry chimneys nominal sizes of 8 x 8 or 8 x 12 200 mm x 200 mm 200 mm x 300 mm may be used AN APPROVED CANADIAN WALL PASS THROUGH Hole with a minimum clearance of 18 450 mm between connec...

Страница 19: ...e many fireplaces have exposed wooden mantels and trim pay special attention to the clearances necessary to these materials If your fireplace chimney is behind a combustible wall you must use an approved wall pass through system to gain access to the masonry chimney The chimney connector must enter the chimney at a place where it is lined and the fireplace must be made inoperable For example you m...

Страница 20: ... 08690 4 metallic blue 1 70 08690 5 honey glo 1 70 08690 10 mojave red 1 70 08690 12 Forest green Ending manufacturing date june 2011 1 70 08690 1 black 1 70 08690 2 Charcoal 1 70 08690 3 goldenfire beginning manufacturing date N A Ending manufacturing date Active 1 14 3 2 4 5 6 22 21 7 8 9 16 18 12 13 15 10 11 20 19 17 ...

Страница 21: ...66 Y 10 Blower option includes 3 speed control 1 00 08643 Y 11 Grate long 15 in cast Qty 2 req 3 00 00208 Y 12 Grate link 2 00 852119 Y 13 Brick 9 X 4 1 2 x 1 1 4 Pkg of 7 1 00 900450125 Y 14 Brick Supports 1 Set 1 00 0872456 15 Ash Door Assembly 1 10 08718A Ash Door Latch Hardware 1 00 85223 Y 16 Airslide Knob Pkg of 3 3 40 08746 3 17 Ash Pan 1 10 08690 Y 18 Ash Lip Trim Gold 3 43 4722386 19 Door...

Страница 22: ...rope Front load door 20 Ft 1 00 1086204 Y Gasket Round black 1 4 w psa glass 15 Ft 1 00 2312 Y Gasket Round white ld 5 8 ash door 1 00 10000 Y Glass retainer clip Pkg of 4 2 00 05202 4 Y Handle Cooking Grill 2 00 852169L Hinge old style punched 1 Set 1 00 04174 Paw bolt old style 4 31 08055 Y Screw 10 24 x 3 8 Alloy Steel Black Oxide Button Head Cap Pkg of 100 3 30 3011 100 Y Screw 1 4 20 x 2 1 2 ...

Страница 23: ...struction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor for cove...

Страница 24: ...lt of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes Repair or r...