background image

The

 l

ow 

d

raft 

Pressure 

Switch

 is 

dif

ferential 

pressure 

switch 

that 

senses 

the 

pressure 

between 

the 

firebox 

and 

the 

room. 

If 

the 

negative 

pressure 

in 

the 

firebox 

becomes 

too 

low 

for 

proper 

combustion, 

the 

switch 

opens, 

interrupting 

power 

to 

the 

feed 

motor 

and 

the 

igniter

.  

If 

the 

switch 

"opens" 

during 

rest 

period, 

the 

control 

will 

not 

try 

to 

feed 

or 

ignite. 

If 

the 

circuit 

op

en

du

rin

fee

or 

ign

itio

cycl

e, 

the

 ind

ica

tor 

ligh

ts 

w

ill 

remain "on".

The 

Control 

b

oard/ESP

 

combination 

is 

responsible 

for 

all 

high 

limit 

safety 

control. 

There 

are 

high 

limits, 

one 

normal 

op

-

eration 

high 

limit 

and 

one 

backup 

high 

limit. 

The 

control 

has 

an 

automatic 

diagnostic 

circuit 

that 

continuously 

monitors 

the 

ESP

 

and 

Room 

Sensor 

for 

faults. 

If 

fault 

should 

occur

, the 

control 

sends 

status 

alert 

and 

 at 

the 

same 

time 

the 

unit 

goes 

down 

to minimum feed/minimum burn as a safety condition.

Accentra 

m

otor & Component 

locations

Accentra Pellet Stove Safety 

d

evices

ESP- Probe

Low Draft  Pressure  Switch

Air Intake Flapper

Feed Motor

Combustion Blower

Distribution Blower

3" Flue Pipe Connector

The

 h

opper 

lid 

Position 

Switch

 is 

plunger 

style 

switch 

located 

in 

the 

hopper 

lid 

opening. 

When 

the 

hopper 

lid 

is 

closed 

properly

, it 

closes 

the 

switch. 

If 

the 

hopper 

lid 

is 

not 

fully 

closed, 

th

sw

itc

op

en

s,

 in

te

rc

ep

tin

po

w

er

 to

 th

fe

ed

 m

ot

or

 a

nd

 ig

ni

te

r. 

If 

th

sw

itc

"o

pe

ns

" d

ur

in

re

st

 p

er

io

d,

 th

co

nt

ro

l w

ill 

no

t t

ry

 to 

feed 

or 

ignite. 

If 

the 

circuit 

opens 

during 

feed 

or 

ignition 

cycle, 

the indicator lights will remain "on".

Содержание Accentra

Страница 1: ...SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authority such as municipal...

Страница 2: ...curred If creosote has accumulated it should be removed to reduce the risk of a chimney fire Guidance on minimizing creosote formation and the need for periodic creosote removal The chimney should be...

Страница 3: ...t once a year To remove the feeder cover Remove the 5 16 wing nut Lift the cover off of the tab at the top and the threaded stud Inspect and clean the inner chamber if necessary See above picture Rein...

Страница 4: ...to clean the heat exchanger surfaces A wire brush or short bristled brush is an excellent cleaning tool Clean the fan blade and combustion blower fan housing NOTE Be careful not to bend the fan blade...

Страница 5: ...lps knock scale off of the igniter element Figure 41 The igniter is made to be removable for service by insulated male female wire connectors These connections between the hot leads the wires inside t...

Страница 6: ...ic circuit that continuously monitors the ESP and Room Sensor for faults If a fault should occur the control sends a status alert and at the same time the unit goes down to minimum feed minimum burn a...

Страница 7: ...code 1 No pellets in hopper 2 Draft setting is too low 3 Something is restricting fuel flow 4 Hopper lid not closed properly 5 Power failure or blown fuse SMOKE IS VISIBLE COMING OUT OF VENT 1 Air fu...

Отзывы: