HI 2151 SERIES WEIGHT CONTROLLERS REMOTE I/O OPTION
5-20
Block Write
Command Number
55: Calibration
Parameters
TABLE 5-22: BLOCK WRITE COMMAND NUMBER 55: CALIBRATION PARAMETERS
BLOCK WRITE COMMAND NUMBER 55: Calibration Parameters
START
WORD DEFINITIONS:
#WORDS
WORD
Command number: A value of 55 (decimal)
bit 0
1
bit 1
1
bit 2
1
bit 3
0
bit 4
1
bit 5
1
bit 6
0
bit 7
0
bit 8 - 15
Reserved for future use
1
0
Units of Measure:
bits 0 - 7
0 = pounds, 1 = kilograms
Decimal point position (places to right of decimal):
bits 8 - 15
A value from 0 to 4
1
1
Totalizer decimal point position (places to right of decimal):
bits 0 - 7
A value from 0 to 4
C2™, Second Generation Calibration
bits 8 - 15
Load Cell Count (set to zero for Hard Cal)
1
2
Display Graduation Size (“count by”): A value of 1,2,5,10,20,50,100,200 or 500
1
3
Motion Tolerance: A sixteen bit value representing the lower 16 bits of the 20 bit
internal weighing range
1
4
Zero Tolerance: A sixteen bit value representing the lower 16 bits of the 20 bit inter-
nal weighing range
1
5
Number of readings averaged: A value from 1 to 200
1
6
Span weight value (Use one of the following methods. Method one, with C2, Sec-
ond Generation Calibration: Use the C2 reference point when using C2 load cells.
Method two: use test weights for calibration) A 20 bit number in proper integer for-
mat
2
7
Scale Capacity (Full limit of scale): A 20 bit number in proper integer format
2
9
Mid-point Linearity calibration value: A 20 bit number in proper integer format
2
11
TOTAL NUMBER OF WORDS
13