Hardy Floor Scales
2
Excitation
Recommended 5 Volts DC
•
Maximum 5 Volts DC
WARNING
FOR SCALES FITTED WITH AN INTEGRATED
TECHNICIAN SUMMING CARD, DO NOT
EXCEED 5 VDC EXCITATION. DOING SO MAY
CAUSE PROPERTY DAMAGE. DO NOT USE
WITH ANY INSTRUMENT WITH AN EXCI-
TATION VOLTAGE ABOVE 5 VDC.
Load Points
HARDY ADVANTAGE® Load Sensors
•
Factory Matched
•
Stainless Steel
•
True Hermetic Seal
•
No Cornering
Total Error
0.03% of FS Output
Maximum
Overload
100% of the Rated Scale Capacity
End Loading
100% of the Rated Scale Capacity
HI 6011 Summing
Box Power Rating
5 VDC, Class 2 source, max. 50 mA
For Class I and II, Division 1 Hazardous (Classified)
Locations, and Class 1, Zone 0 and 2 Groups IIC,
Zone 20 and 22 Groups IIIC, power must be supplied
to the summing box through approved intrinsically
safe barriers per control drawing 0594-0010. (Avail-
able for download on the Hardy Floor Scales webpage
under Docs & Programs).
Certifications
•
UL, CUL, CE
•
RoHS3 and REACH Compliant
•
Hazardous Areas:
Class I, Division 1,
Groups A, B, C, D, T4; Zone 0, Group IIC,
T4; Division 2, Groups A, B, C, D, T5
•
Class II, Division 1, Groups E, F, G, T4;
Zone 20, Group IIIC; Division 2, Groups F,
G, T5
•
Class III, Division 1, T4; Division 2, T5