Chapter 4 - Setup
4-9
Reading from the
32 Word Logical I
and logical M1
files
Reads are all done in the I file (not to be confused
with the “logical I file”). Word #0 will always be a
copy of the “Command Word”. Words 1-7 of the I file
can be configured to read up to 7 words from either
the Logical M1 or the Logical I file (you cannot read
from both at the same time).
Command Word
Bits 15-14 set
to “10”
Allows the user to specify what words (up to 7) from
the logical I file to appear in words 1-7 in the I file.
For
Example
If bits 15-14 are set to 10 in “Command Word” and
words 1-7 of the O file are: 18,19, 20, 21, 16, 15, 24.
The return in the I file words 0-7 would be (in order):
“Command Word”, gross weight (MSW), gross
weight (LSW), net weight (MSW), net weight (LSW),
relay status, module status, and ROC evaluation
period.
Bits 15-14 set
to “11”
When written to the logical M0 file, will cause the I
file to reflect the words at the same starting offset in
the logical M1 file as specified in bits 7-0.
For
Example
If 2 words are written to the logical M0 file starting at
offset word 28, then offset words 28 and 29 of the log-
ical M1 file would appear in words 1 and 2 of the I
file.
Bits 15-14 set
to “01”
For a write will cause the I file to reflect the words
previously selected to read using the “10” setting.
NOTE:
The selected words to read are not necessarily the
ones being written to using the “01” setting.
Bits 15-14 set
to “00”
Returns the configuration set up with the “10” com-
mand.
NOTE:
After an input byte is configured, the 1746 will
remember the configuration as long as it has power.
The Configuration is lost after you power down.
Содержание C Series
Страница 8: ...HI 1746 WS WEIGHT SCALE MODULE vi...
Страница 10: ...HI 1746 WS WEIGH SCALE MODULE II...
Страница 46: ...HI 1746 WS WEIGH SCALE MODULE 4 16 I O Setup Ladder Logic for Remote Mode Operation...
Страница 47: ...Chapter 4 Setup 4 17...
Страница 53: ...Chapter 4 Setup 4 23 SETPARAMS Local Mode of Operation FIG 4 4 SETPARAMS LADDER LOGIC EXAMPLE LOCAL MODE...
Страница 54: ...HI 1746 WS WEIGH SCALE MODULE 4 24 SETPARAMS Remote Mode of Operation...
Страница 55: ...Chapter 4 Setup 4 25...
Страница 56: ...HI 1746 WS WEIGH SCALE MODULE 4 26...
Страница 60: ...HI 1746 WS WEIGH SCALE MODULE 4 30...
Страница 68: ...HI 1746 WS WEIGH SCALE MODULE 5 8 C2 Calibration Ladder Logic Example For Local Mode of Operation Only...
Страница 69: ...Chapter 5 Calibration 5 9...
Страница 70: ...HI 1746 WS WEIGH SCALE MODULE 5 10 FIG 5 5 C2 LADDER LOGIC EXAMPLE LOCAL MODE OF OPERATION...
Страница 71: ...Chapter 5 Calibration 5 11 C2 Calibration Ladder Logic Example For Remote Mode of Operation Only...
Страница 74: ...HI 1746 WS WEIGH SCALE MODULE 5 14...
Страница 84: ...HI 1746 WS WEIGH SCALE MODULE 6 10...
Страница 92: ...HI 1756 WS MANUAL...