Page 20 of 22
CUS-013-0028-09
6.
Troubleshooting
DISCONNECT POWER TO THE ROTISSERIE BEFORE ANY MAINTENANCE, SERVICE OR
CLEANING IS PERFORMED.
ROTISSERIES EQUIPPED WITH CASTERS ARE SECURED IN PLACE USING A RESTRAINING
CABLE LOCATED ON THE RIGHT REAR UNDERSIDE OF THE ROTISSERIE. THIS CABLE MUST
BE DISCONNECTED PRIOR TO REMOVING THE ROTISSERIE AND CAUTION MUST BE TAKEN
TO ENSURE IT IS CONNECTED ONCE THE ROTISSERIE HAS BEEN RETURNED TO ITS
ORIGINAL POSITION.
THE ROTISSERIE IS HOT WHEN OPERATING. EXERCISE CAUTION WHEN WORKING NEAR THE
HOT ROTISSERIE.
WEAR APPROPRIATE PROTECTIVE CLOTHING BEFORE ANY MAINTENANCE, SERVICE OR
CLEANING IS PERFORMED.
Rotisserie Does Not Operate
SYMPTOM:
The rotisserie does not operate when the red main ON/OFF switch is pulled out (i.e. drive does not turn, and
no lights in cavity).
SOLUTION:
Verify that the door is fully closed. The magnetic
door switch disables or enables the ignition
system.
Check rotisserie electrical power: If the
rotisserie's lights are off, check the circuit breaker
on the back of the rotisserie as shown in Figure
3-1 on page 6 and Figure 3-2 on page 7. If the
circuit breaker is ‘OFF’ (tripped), return to 'ON'.
If this
circuit breaker is ‘ON’, ensure that the
power cord is plugged into the wall and that there
is power coming from the socket. If power is
available and the rotisserie still does not operate,
contact your local authorized service partner.
Figure 6-1
Safety Lockout
SYMPTOM:
If the preheat (or cooking) cycle is initiated, the drive drum will rotate and the igniter will attempt to light the
burner. If there is no flame after six minutes, the rotisserie will go into Safety Lockout mode, an alarm will
sound and the red SLO (Safety Lockout) alarm lamp on the control panel will illuminate.
Possible causes include: the gas supply valve is shut off, the flame sensor is not sensing flame or there is
some component failure.
SOLUTION:
If the rotisserie goes into
Safety Lockout
, press and hold STOP
for 3 seconds to end the cycle
or push the red main ON/OFF switch to turn the rotisserie off.
Verify that the gas supply valve to the rotisserie is open. Try starting ignition again by pulling the red
main ON/OFF switch out and by starting a preheat cycle as described in section
on page 9.
If the rotisserie goes into Safety Lockout again there is most likely a component failure. Turn the
rotisserie off by pushing in the red main ON/OFF switch and contact your local authorized Hardt
service provider.
ON
OFF