1. 

GENERAL INFORMATION 

1.1 Producer 

 

HARDO CZAPSKI I WSPÓLNICY SP. J. 

Ul. Spacerowa 5  
32-83  Balice, Poland 

 

1.2 Information on this manual 

 

 

 
NOTE: 

BEFORE USING THE DEVICE, READ THESE INSTRUCTIONS. 

 

This manual describes the rules for safe and correct handling of devices. The safety recommendations contained in the 
manual, accident prevention measures as well as general safety measures must be followed. The instructions should 
be accessible to operating and maintenance personnel and kept throughout the useful life of the product.

 

 

1.3 Compliance with standards and regulations 

 

OptiLine series lighting fixtures have been designed and manufactured in accordance with the requirements of: 
 
 

a)  Directive on the harmonization of the laws of the Member States relating to equipment and protective systems 

intended for use in potentially explosive atmospheres  

ATEX 2014/34/EU. 

b)  Directive on electrical equipment designed for use within certain voltage limits 

LVD 2014/35/EU

 

c)  Directive on the harmonisation of the laws of the Member States relating to electromagnetic compatibility 

EMC 

2014/30/EU.

 

 

 
A detailed summary of standards is included in the EU declaration of conformity. 

 

2. 

DEVICE DESCRIPTION 

 

OptiLine luminaires are luminaires equipped with high-efficiency LED light sources. Depending on the version, they can 
be  used  as  basic  and/or  emergency  lighting.  The  product  meets  the  essential  safety  requirements  contained  in  the 
ATEX Directive for category II devices of categories 3G, 2D and 3D, as well as the requirements of the IECEx system. 
Detailed guidance on potentially explosive atmospheres is given in this document. 
Luminaires are approved for use in both external and internal installations. The external housing of OptiLine luminaires 
is made of glass fibre reinforced polyester (GRP) bottom body and made of polycarbonate (PC) diffuser which is also 
the lampshade of the luminaire. The luminaire shade is available in three versions: transparent, opal and frosted. It is 
possible to use LED drivers with the DALI system in luminaires. 
The connection of both these elements is sealed with a gasket made of silicone foam.  
External  electrical  cables  have  to  be  introduced  into  the  housing  using  certified  cable  glands.  Depending  on  the 
components used, they have a degree of protection against the ingress of solids and liquids at the level of IP 66/67. The 
housing of the luminaires is resistant to moisture and UV radiation, which allows  it to work in outdoor conditions. The 
housing  materials  used  provide  high  resistance  to  mechanical  impact.  The  luminaire  is  made  as  a  single-chamber 
device. The  housing  is  closed/opened  by  means  of stainless  steel  closing  clips  that  prevent  the  housing  from  being 
opened  without  a  tool.  Inside  the  housing,  there  is  a  bottom  frame  made  of powder-coated  steel.  Depending  on  the 
configuration of the luminaire, the lower frame is a place of installation for: LED driver, cable connectors, through wiring, 
Ni-Cd battery pack, CBX and CBY switching modules. The bottom frame is attached to the GRP bottom body with plastic 
mounting  screws.  The  HEX5416  1/2/3  LED  light  modules  are  mounted  to  the  powder-coated  steel  top  frame.  Both 
frames are connected to each other by means of a set of rivet nuts and bolts.

 

Содержание OptiLine A1 Series

Страница 1: ...1 z 16 USE AND MAINTENANCE INSTRUCTION OF LIGHTING FIXTURE OptiLine A1 SERIES Instruction no K 26190 PW 0006 HARDO Czapski i Wsp lnicy Sp j Release date 04 04 2024 ul Spacerowa 5 Issue no 1 3 32 083...

Страница 2: ...n 7 5 2 Installation 8 5 3 Electrical connection 10 5 3 1 General requirements 10 5 3 2 Execution of luminaire electrical connections 10 6 WORK IN EMERGENCY MODE 11 6 1 General information 11 6 2 Batt...

Страница 3: ...ements of the IECEx system Detailed guidance on potentially explosive atmospheres is given in this document Luminaires are approved for use in both external and internal installations The external hou...

Страница 4: ...50Hz In emergency mode they are powered from a built in Ni Cd battery pack ensuring backup in emergency mode of not less than 1 5 hours A detailed description of the possible configurations and their...

Страница 5: ...log card of the OptiLine lighting fixture 2 2 Ex marking Depending on the version OptiLine series luminaires are marked with Ex features as follow II 3G Ex ec IIC T4 Gc II 2D Ex tb IIIC T70 C Db The i...

Страница 6: ...s a high level of safety and which will not become a source of ignition under normal conditions of use and during expected damage 3 SAFETY 3 1 General precautions DANGER THE EXPLOSION HAZARD CAUSED BY...

Страница 7: ...t temperature range is unacceptable and will lead to faster wear and or damage At the same time it causes the loss of the manufacturer s warranty Note The use of a luminaire outside the designated ran...

Страница 8: ...the GRP lower body At the place where the nuts are mounted the mounting brackets must be fixed with M8 15 mm bolts and M8 spring washers M8 screws should be tightened with a torque of 9 10 Nm Install...

Страница 9: ...Strona 9 z 16 Figure 3 Acceptable mounting position...

Страница 10: ...5 4 mm2 for luminaires powered on one side Single core cross section 2 5 4 mm2 for pass through or crossed powered luminaires Outer diameter of the cable 8 17 mm the value depends on the size and type...

Страница 11: ...ts for emergency lighting OptiLine luminaires A1 have implemented Built in automatic functional test execution Functional tests last one minute and are performed first 1 hour after the first start nex...

Страница 12: ...the capacitance test performed at least once every 52 weeks WARNING ALL REPAIRS INCLUDING REPLACEMENT OF THE LIGHT SOURCE OR BATTERY PACK CAN ONLY BE CARRIED OUT USING ORIGINAL SPARE PARTS AND ONLY BY...

Страница 13: ...At least once every 1 months a visual and close inspection of the lighting fixture should be carried out During the visual inspection luminaires do not need to be disconnected from the power source Th...

Страница 14: ...OSIVE ATMOSPHERE In accordance with the requirements of local regulations electrical tests related to Measurement of the current consumed by the luminaire Measurement of the condition of the insulatio...

Страница 15: ...2 2 Photometric data Photometric data for OptiLine A1 for an ambient temperature of 25 C a bar temperature of 4000K and a colour rendering index CRI 80 are shown in Table 3 Type Luminous flux with AC...

Страница 16: ...dimensions of OptiLine luminaires are shown in Figure 5 and Table 5 Figure 5 Basic dimensions of OptiLine luminaires Type L L1 B H OptiLine 60 670 400 173 107 OptiLine 12 1276 800 173 107 Table 5 Bas...