Strona
14
z
16
The scope of the detailed inspection should include:
•
Scope of activities for visual and close inspection;
•
Checking the condition of protective coatings of internal elements of the lighting fixture;
•
Checking the condition of internal components, e.g.: cable connections, cable connectors, power supply,
LED modules, cable glands;
•
Verification of the installation site in terms of possible environmental changes, e.g.: type of hazardous area,
temperature class, surface temperature, tightness class.
All irregularities identified shall be remedied. A detailed description and scope of activities is included in the
PN-EN/IEC 60079-17:2014-05 standard.
8.3 Additional requirements
DANGER:
EXPLOSION HAZARD. THE FOLLOWING MEASUREMENTS SHALL BE TAKEN IN
THE ABSENCE OF AN EXPLOSIVE ATMOSPHERE
In accordance with the requirements of local regulations, electrical tests related to:
•
Measurement of the current consumed by the luminaire;
•
Measurement of the condition of the insulation;
•
Measurement of the effectiveness of the protective connection
9.
REPAIRS
WARNING:
THE USE OF A DAMAGED DEVICE IS PROHIBITED AS IT MAY LEAD TO
PERSONAL INJURY OR PROPERTY LOSS. THE MANUFACTURER DOES NOT BEAR ANY
LIABILITY IN SUCH CASES
.
WARNING:
ALL REPAIRS, INCLUDING REPLACEMENT OF THE LIGHT SOURCE OR
BATTERY PACK, CAN ONLY BE CARRIED OUT USING ORIGINAL SPARE PARTS AND ONLY
BY THE MANUFACTURER OF THE LUMINAIRE OR AN AUTHORIZED SERVICE.
10.
DISPOSAL
A symbol placed on the product or on the packaging indicates that the product should
not be considered normal household waste but must be recycled for electrical and
electronic equipment.
11.
WARRANTY CONDITIONS
To read the warranty conditions, please refer to our General Terms and Conditions available at