61
5 - Operation
Filling through tank lid
The tank is filled with water through the filling hole by removing the
lid located on the top of the tank. The water used should be as clean as
possible to obtain best results.
Fill the tank using the filter to prevent impurities from entering the
tank. For greater filling capacity, an overhead tank can be used.
DANGER! Do not place the filling hose inside the tank. Keep it
out of the tank at all times and only point it towards the filling
hole. If the pressure hose were placed inside the tank and there
was a drop in water supply pressure, the chemical product
could be syphoned back and contaminate the water supply
lines, plant and well.
ATTENTION! The water supply line should be provided with a check valve as additional safety precaution. Follow
local legislation in force at any time.
ATTENTION! The water supply should be provided with a meter to avoid spillage by over-filling. Follow local
legislation in force at any time.
Filling the rinsing tank
The rinsing tank is integrated with the main tank.
Capacity: 40 , 60 or 100 litres for 400, 600 , 1000 and 1200 litres main
tanks, litres for 2000 .
The illustration shows the location of the rinse tank. Fill though lid A.
ATTENTION! Only fill rinsing tank with clean water! To avoid
algae developing in the rinsing tank always drain the rinsing
tank if the sprayer is not in use for a longer period of time.
To clean the tank select “Rinsing tank” on the three-way valve located
above the suction filter.
The multi-hole rinsing nozzle is located inside the main tank.
When pressurized the multi hole nozzle will rotate fast and rinse down
spray chemical residues from the tank walls. To activate this multi-hole
rinsing nozzle for internal cleaning you should turn the tap located on
the pressure distributor.