          To reduce the risk of fire, electrical shock or personal injury, mount fan to outlet box

 

          marked "ACCEPTABLE FOR FAN SUPPORT OF 35 LBS. (15.9 KG) OR LESS" and

 

           use mounting screws provided with the outlet box. Most outlet boxes commonly used 

for the support of lighting fixtures are not acceptable for fan support and may need to be replaced. 
Consult a qualified electrician if in doubt. 

 

When mounting fan to a ceiling outlet box, use a METAL octagonal outlet box; do NOT use a 
plastic outlet box. Secure the outlet box directly to the building structure. The outlet box and its 
support must be able to support the moving weight of the fan (at least 35 lbs.). 

 

To avoid personal injury, the use of gloves may be necessary while handling fan parts with
sharp edges.

 

To reduce the risk of fire, electrical shock or personal injury, wire connectors provided with this fan 
are designed to accept only one 12-gauge house wire and two lead wires from the fan. If your 
house wire is larger than 12-gauge or there is more than one house wire to connect to the  
corresponding fan lead wires, consult an electrician for the proper size wire connectors to use.

 

To reduce the risk of fire or electrical shock, do not use the fan with any solid state speed control 
device or control fan speed with a full range dimmer switch.

 

To reduce the risk of fire, electrical shock or personal injury, do not insert objects between the 
rotating fan blades.

 

To reduce the risk of personal injury, use ONLY parts provided with this fan. The use of parts 
OTHER than those provided with this fan will void the warranty.

 

Before installation, be sure to shut off electricity at main switch or circuit breaker in order to avoid 
electrical shock.

3

SAFETY INFORMATION

WARNING

  

DANGER

When using an existing outlet box, make sure the outlet box is securely attached to the building 
structure and can support the full weight of the fan. Failure to do this can result in serious injury or 
death.

 The stability of the outlet box is essential in minimizing wobble and noise in the fan after 

installation is complete.

 

To reduce the risk of serious bodily injury, DO 

NOT use power tools to assemble any part of the 

fan, including the blades.

Содержание MAZON MZ44BNK3LR

Страница 1: ...mark of LF LLC All Rights Reserved Español p 18 1 ATTACH YOUR RECEIPT HERE Purchase Date BM19404 Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 8 p m EST Monday Sunday 4007498 ATTACH YOUR RECEIPT HERE ADJUNTE SU RECIBO AQUÍ ...

Страница 2: ...trician or consult a do it yourself wiring handbook if you are unfamiliar with installing electrical wiring Make sure the installation site you choose allows a minimum clearance of 7 ft from the blades to the floor and at least 30 in from the end of the blades to any obstruction After you install the fan make sure all connections are secure to prevent the fan from falling The net weight of this fa...

Страница 3: ...re is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use To reduce the risk of fire or electrical shock do not use the fan with any solid state speed control device or control fan speed with a full range dimmer switch To reduce the risk of fire electrical shock or personal injury do not insert objects between th...

Страница 4: ... against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio...

Страница 5: ...B Canopy Ring 1 C Motor Assembly 1 D Fitter Plate 1 E Glass Shade 1 F Fitter Plate Screw 3 preassembled G Blade 3 DESCRIPTION PART QUANTITY H LED Light Kit 1 I Mounting Plate Lock 4 Washer preassembled J Mounting Plate Screw 4 preassembled K Motor Plate Screw 3 preassembled L Remote Pack 1 DESCRIPTION PART QUANTITY B G I H K C E A J D F L ...

Страница 6: ...uded Electrical Tape Phillips Screwdriver Pliers Safety Glasses Stepladder and Wire Strippers Helpful Tools not included AC Tester Light Tape Measure Do It Yourself Wiring Handbook and Wire Cutters PREPARATION AA CC Wire Connector Qty 3 1 extra CC Blade Screw Qty 9 1 extra Fiber Blade Washer Qty 9 1 extra BB INITIAL INSTALLATION Turn off circuit breakers and wall switch to the fan supply line lead...

Страница 7: ...s G will be at least 30 inches from any obstruction and at least 7 ft above the floor 2 2 7 ft min 30 in min G 3 3 C Secure mounting plate A to outlet box using screws spring washers and flat washers provided with the outlet box NOTE It is very important you use the proper hardware when installing the mounting plate A as this will support the fan Pull electrical wiring from outlet box through cent...

Страница 8: ... to rest on top of motor for the time being Motor J Hook 8 6 7 INITIAL INSTALLATION 3 5 Locate mounting plate screw J mounting plate lock washer I on outer edge of mounting plate A that is closest to the j hook and remove that mounting plate screw J mounting plate lock washer I Also remove mounting plate screw J mounting plate lock washer I on outer edge of mounting plate A directly opposite the o...

Страница 9: ...UND GREEN wires together from fan on motor assembly C and mounting plate A to BARE GREEN wire from ceiling ROUND GREEN BARE WHITE BLACK BLACK WHITE ROUND GREEN BARE GROUND GREEN BLACK WHITE WHITE FROM FAN N BLACK WHITE FROM FAN WHITE GROUND GREE GROUND G WHITE BLACK 120 V Power from ceiling 1 C A WARNING The wires from the outlet box must be connected to a corresponding color of the fan s wires Be...

Страница 10: ...four grooves at top of motor assembly C and raise canopy B until you hear tabs snap into grooves NOTE Canopy ring B should fit flush to ceiling when done correctly Remove motor assembly C from J hook and slide top of motor assembly C over mounting plate A aligning slotted holes in motor assembly C with loosened mounting plate screws J mounting plate lock washers I in mounting plate A Twist motor a...

Страница 11: ...fitter plate screw F from fitter plate D and partially loosen the other two fitter plate screws F Connect male plug from motor assembly C to female plug from fitter plate D matching up the colors on the plugs for correct fit Make sure plugs connect tightly 4 3 5 Remove one motor plate screw K from motor plate preassembled on the underside of the motor assembly C and partially loosen the other two ...

Страница 12: ...ghten all three fitter plate screws F securely 6 3 6 BLUE WHITE WHITE BLUE Loosened Screws H D F Align slots on glass shade E with protrusions on the inside of the fitter plate D Turn glass shade E to the right clockwise until it no longer turns NOTE Pull down gently on the glass shade E to make sure that it is secured completely 7 3 7 C E 8 Remote Control Bracket Wall 8 If you wish to use the rem...

Страница 13: ... on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Remove contents of remot...

Страница 14: ...button for fan HIGH speed 2 button for fan MEDIUM speed 1 button for fan LOW speed 0 button to turn fan OFF button to turn light ON or OFF Tap button quickly to turn lights off or on Hold button down to increase or decrease lights If you press button in excess of 0 7 seconds it becomes a dimmer The lights vary cyclically in 8 seconds The light button has an auto resume function which keeps the lig...

Страница 15: ... setting the reverse switch in the RIGHT position will result in upward airflow that can help move stagnant hot air off the ceiling area At least twice each year check mounting plate screws J and then tighten all screws on the fan Clean motor assembly C with only a soft brush or lint free cloth to avoid scratching the finish Clean blades G with a lint free cloth IMPORTANT Shut off main power suppl...

Страница 16: ...blade 3 Full range dimmer switch 4 Fan is new 5 Motor assembly is loose 1 Tighten all blade screws 2 Replace blade 3 Use only with included speed control device 4 Allow fan a break in period of a few days especially when running the fan at Medium and High speeds 5 Verify mounting plate screws are secure according to instructions on page 10 TROUBLESHOOTING Excessive wobbling 1 Blades are loose 2 Bl...

Страница 17: ...ying weather conditions Any glass provided with this fan is not covered by the warranty Any replacement of defective parts for the ceiling fan must be reported within the first year from the date of purchase For the balance of the warranty call our customer service department at 1 800 643 0067 for return authorization and shipping instructions so that we may repair or replace the ceiling fan Any f...

Отзывы: