HANYOUNG NUX TPR-3SL Скачать руководство пользователя страница 1

3

4

Suffix code

Model

Code

Information

TPR-3SL

-

Slim type 3-phase power regulator

Rated current

040

40 A

055

55 A

070

70 A

090

90 A

130

130 A

160

160 A

Power supply voltage

L

100 - 240 V AC (Low)

H

380 - 440 V AC (High)

Option

-

FUSE is installed

N

No Fuse

※ Circuit and FAN need 100 - 240 V AC voltage power separately.

Specification

Model

Low

TPR-3SL040L

TPR-3SL055L TPR-3SL070L TPR-3SL090L TPR-3SL130L TPR-3SL160L

High

TPR-3SL040H TPR-3SL055H TPR-3SL070H TPR-3SL090H TPR-3SL130H TPR-3SL160H

Power supply voltage

100 - 240 V AC (Low)

380 - 440 V AC (High)

Circuit input power

100 - 240 V AC

Power frequency

50 Hz / 60 Hz (Dual usage)

Rated current

40 A, 55 A, 70 A, 90 A, 130 A, 160 A

Applying load

Resistive load

Control 

Input

Current input

4 - 20 mA DC (Impedance : 100 Ω)

Voltage input

1 - 5 V DC

Contact input

ON / OFF

External V.R

External volume (10 ㏀)

Control method

Phase control, Fixed Cycle control, Variable Cycle control, ON/OFF control

Movement type

SOFT START, SOFT UP/DOWN

Output voltage

More than 98 % of the power supply voltage (In case of maximum current input)

Cooling method

Natural cooling (40 A, 55 A), Forced cooling (70 A, 90 A, 130 A, 160 A)

Display method

Display by LED

Insulation resistance

Min 100 MΩ (Base on 500 V DC mega)

Output control range

0 ~ 100 %

Dielectric strength

3000 V AC 50/60 Hz for 1 min

Line noise

Noise by noise simulator (2,500 V)

Ambient temperature

0 ~ 40 ℃ (Without Condensation)

Ambient Humidity

30 ~ 85 % RH

Storage temperature

-25 ℃ ~ 70 ℃

Weight

4,044 g

4,324 g

9,100 g

Appearance

[Unit : mm]

Connection diagram

▒ Connection diagram of load terminal

▒ Connection diagram of signal and alarm terminal

INPUT

LOAD

· Inside of TPR, the fuse is installed in the R,S,T input power supply 
    portion depending on the specification of options
· When connecting terminals, please use crimp connectors and 
    securely fasten them due to the high current flow.
    (Max space for solder less terminal connection is 
     40/55/70 A : 16 mm, 90/130/160 A : 26 mm)

• No. ①, ② and ③ : manual V.R

· Use variable resistor of 10 ㏀ 
· Control 0 ~ 100 % manually

• No. ④ and ⑥ : RUN/STOP

· Be sure to attach RUN contact while it is operating.

• No. ⑤ and ⑥ : ON/OFF control

· When inputting contact, it is operated with 100% output,
    irrespective of other control input.

• No. ⑦, ⑧ and ⑨ : Alarm 1 - Warning

   This is a “warning” alarm which implies that there may be a 
   cause of damage to the product and load. At this moment, 
   TPR stops the output by itself and “warning” alarm is activated.
 · Warning error : Overcurrent, SCR short-circuit, 
                         Fuse Disconnection, Power problem

• ⑩, ⑪, ⑫: Alarm 2 (Caution)

    This is a “caution” alarm which implies there is not a serious  
    problem, but user needs to check for its system because small and 
    minor problems cause this alarm. At this moment,  the output of TPR 
    is normally operating but only “caution” alarm is activated.
 · Caution error : Load unbalance, load disconnection, 
                       overheated heat (65 ℃)
• Initially ⑦ & ⑧ connect. If alarm 1 is activated, ⑧ & ⑨ will be connected.
• Initially ⑩ & ⑪ connect. If alarm 2 is activated, ⑪ & ⑫ will be connected.

MB0601KE140806

 

Power REGULATOR

 

TPR-3SL

      

 

        

 

Thank you for purchasing HANYOUNG product.

        Please check whether the product is the exactly same as you ordered. 
        Before using the product, please read this instruction manual carefully.
        Please keep this manual where you can view at any time

 

28, Gilpa-ro 71beon-gil, Nam-gu, Incheon, Korea
TEL : (82-32)876-4697     FAX : (82-32)876-4696
http://www.hynux.com

HANYOUNGNUX CO.,LTD

HEAD OFFICE

JL.CEMPAKA BLOK F 16 NO.02 DELTA SILICON II INDUSTRIAL PARK 
LIPPO CIKARANG CICAU, CIKARANG PUSAT, BEKASI INDONESIA 17550
TEL : 62-21-8911-8120~4  FAX : 62-21-8911-8126 

PT. HANYOUNG ELECTRONIC INDONESIA

INDONESIA

FACTORY

 INSTRUCTION MANUAL

•Please install appropriate protective circuit on the outside if malfunction or an incorrect operation may be 
   a cause of leading to a serious accident.
•If you use the product with methods other than specified by the manufacturer, there may be  bodily injuries 
   or property damages.
•Since this product is not designed as a safety device if it is used with systems, machines and equipment 
   that could lead to a risk of life or property damage, please implement safety devices and protections for 
   both lives and the applications and plan for preventing accidents. 
•To prevent damage or failure of this product, please supply the rated power voltage.
•To prevent electric shock or equipment failure, please do not turn on the power until completing wiring.
•Never disassemble, modify, or repair the product. There is a possibility of malfunction, electric shock, 
   or a risk of fire.
•Please turn off the power when mounting / dismounting of the product. This is a cause of electric shock, 
   malfunction, or failure.

Warning

Safety information

Before using the product, please read the safety information thoroughly and use it properly.Alerts declared in the manual 
are classified to Danger, Warning and Caution by their criticality

DANGER

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury

WARNING

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury

CAUTION

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury

To prevent electric shock while it is running, put to earth with the fixed screw of the unit and do not touch the radiator 
panel since it is very hot. Do not touch or contact the input/output terminals because they cause electric shock.

Danger

•Since the product operating environment influences the product performance and expected life span, 
   please avoid using in the following places.
· a place where humidity is high and air flow is inappropriate.
· a place where dust or impurity accumulates, ambient temperature is high and vibration level is high.
· a place where corrosive gas (such as harmful gas, ammonia, etc.) and flammable gas occur.
· a place where there is direct vibration and a large physical impact to the product.
· a place where there is water, oil, chemicals, steam, dust, salt, iron or others (Contamination class 1 or 2).
· a place where excessive amounts of inductive interference and electrostatic and magnetic noise occur.
· a place where heat accumulation occurs due to direct sunlight or radiant heat.
•Please do not wipe this product with organic solvents such as alcohol, benzene and others. (Please use mild detergent)
•Please make sure to inspect the product if exposed to water since there is a possibility of electric leakage or a risk of fire.
•Please connect the product and other units after turning off all the power of the product, instruments and units.
•Please make sure that the power control (TPR) is installed perpendicularly.
•Please install the product inside of the control panel and install an exhaust fan onto the top of the control panel.
•Pay attention to the edge of heat sink which is sharp. 

Caution

▒ 40/55/70 A

▒ 90/130/160 A

223 (H1)

237 (H2)

110

2-50

4-6.5

4-

8

194.6

213.7

200

239.1

220.5

300.5

30.5

125

230

160

173

270

6-8.5

223 (H1)

237 (H2)

110

2-50

4-6.5

4-

8

194.6

213.7

200

239.1

220.5

300.5

30.5

125

230

160

173

270

6-8.5

H1

H2

70 A (With cooling fan)

249.5 mm

263.5 mm

Отзывы: