HANYOUNG NUX PSC Series Скачать руководство пользователя страница 1

As for PSC Case, connect on the
control board case by 3~5.5MM
electric wire. For the 0 V terminal,
connect on the control board case
with identical type of electrical
wire and earth it.
Perform as indicated above,
and earth the PSC.

Distance from

control box

Below

Above

Wiring of PSC

1. If intense vibration or impact is applied on the transmitter for length 

measurement, the wrong pulse is generated causing malfunction, therefore, 
absolute care is necessary when selecting the installation and disposition 
location.

2. As much as the amount of pulse per cycle, the slit gap of rotation slit is 

narrower, therefore can be easily affected by vibration, and the vibration 
applied during slow rotation or when stationary, may get transmitted to the 
shaft or the main body, causing wrong pulse generation, therefore, please take
caution. The vibration applied to the transmitter for length measurement can 

become a cause for wrong pulse generation, so please take caution in terms

of installation location or location for attachment.

An internal pressure of 500V DC exists between the Case and the electric 
circuit, however, there are dangers of damage the electrical circuit if voltage 
is applied accidentally, so do not perform mega tests.

On Mega Test

1. During installation, do not apply impact on or twist the shaft of the transmitter 

for length measurement.

2. During installation, do not apply excessive force when combining the shaft of 

transmitter for length measurement and the instrument.

3. During installation, take caution because the life span of the transmitter for   

length measurement is dependent on the usage condition and the 
environment.  

4. Do not decompose, modify, revise or repair this product. This may be a 

cause of malfunction, electric shock or fire.

5. Reassemble this product while the power is OFF. Otherwise, it may be a

cause of malfunction or electric shock.

On Installation

About vibration

For noise prevention

1. Separate an input signal cable from an output signal cable. If separating is not

possible, please use the input signal cable after shielding it.

2. If there is excessive noise from the power supply, using insulating transformer

and noise filter is recommended.

3. Do not connect anything to the unused terminals. 
4. After checking the polarity of terminal, connect wires at the correct position.
5. As for wiring, ensure they are as short as possible.
6. Having the same pipe for wiring of the transmitter for length measurement 

with the power line or an identical connection could cause malfunction,  
therefore please take caution.

7. Wrong connection of the wiring of transmitter for length measurement may 

damage the internal circuit. Please take sufficient caution.

About Wiring

1.Before using the product you purchased, make sure that it is exactly what you

ordered.

2. Make sure that there is no damage or abnormality of the product during the

delivery.

3. The transmitter for measuring the length is composed of precision parts, so   

can easily be damaged with external impact, therefore handle with care.

4. The shield wire of the transmitter for length measurement is not connected to 

the case.

5. When the product gets wet, the inspection is essential because there is danger

of an electric leakage or fire.

6. For the continuous and safe use of this product, the periodical maintenance is

recommended.

7. If you use the product with methods other than specified by the manufacturer,

there may be bodily injuries or property damages.

The caution on the safety stated above, must be kept, otherwise malfunction

can be induced. 

Load Current : Max. 30 mA 

Remaining voltage : Max.

Load Current : Max. 10 mA 

Remaining voltage : Min.

Safety information

CAUTION

HEAD OFFICE 

1381-3, Juan-Dong, Nam-Gu Incheon, Korea

TEL: (82-32)876-4697  FAX : (82-32)876-4696

MAIN PRODUCTS
- DIGITAL : Temperature Controller, Counter, Timer,Speedmeter, 

Tachometer, Panel Meter, Recorder

- SENSOR : Proximity Switch/Photo Electric Sensor, 

Rotary Encoder, Optical Fiber Sensor,   
Pressure Sensor

- ANALOG : Timer, Temperature Controller

Rotary Encoder

PSC

We appreciate you for purchasing HanYoung NUX Co.,Ltd
product. Before using the product you have purchased,
check to make sure that it is exactly what you ordered. Then,
please use it following the instructions below.

INSTRUCTION MANUAL

MA0604E070130

Specification

Отзывы: