Chapter 3 Installation
53
3.11
Configuring the General Analog I/O
It can be used to set or measure voltage (0-10V) or current (4-20mA) between two
equipment.
For high reliability, it is recommended that you use the following method.
Use the analog ground closes to the I/O.
Equipment and control box should share the same ground. Analog I/O is not insulated in
the control box.
Use the cable that is shielded or twist paired. Connect it to the ground shield of the power
(J12) terminal.
The current signal is not sensitive to noise, so simply use an equipment operating in current
mode.
The input mode can be set in the GUI. The following electrical specifications apply to
the I/O.
Terminal
Parameter Minimum
Format
Maximum
Unit
Current mode input
AIx - AG
Current
4
-
20
mA
AIx - AG
Resistance
-
20
-
Ohm
AIx - AG
Resolution
-
12
-
Beat
Voltage mode input
AIx - AG
Current
0
-
10
V
AIx - AG
Resistance
-
12
-
Kohm
AIx - AG
Resolution
-
12
-
Beat
Current mode output
AOx - AG
Current
4
-
20
mA
AOx - AG
Resistance
0
-
10
V
AOx - AG
Resolution
-
12
-
Beat
Voltage mode output
AOx - AG
Voltage
0
-
10
V
AOx - AG
Current
-20
-
20
mA
AOx - AG
Resistance
-
1
-
ohm
AOx - AG
Resolution
-
12
-
Beat
Содержание HCR-5
Страница 1: ...HCR 5 Collaborative Robot User Manual Aug 2019 V 2 001 ...
Страница 2: ......
Страница 14: ......
Страница 96: ...Chapter 8 Safety Settings 96 ...
Страница 101: ...Chapter 8 Safety Settings 101 3 Press the OK button ...
Страница 177: ...Chapter 12 Device Settings 177 B When the scanning location and the robot s location are shifted by X ...
Страница 188: ...Chapter 15 Maintenance 188 4 When the confirmation window appears press YES ...
Страница 192: ...192 Appendix B Certification Safety ...
Страница 193: ...193 ...
Страница 194: ...194 MD Machinery Directive ...
Страница 195: ...195 LVD Low Voltage Directive ...
Страница 196: ...196 EMC Electro Magnetic Compatibility ...
Страница 197: ...197 Cleanroom Body ...
Страница 198: ...198 Cleanroom Controller ...
Страница 199: ...199 Appendix C Dimensions for Installation ...
Страница 200: ...200 Appendix D Tool Flange Cross Section The tool flange is designed suitable for ISO9409 1 50 4 M6 ...
Страница 205: ......