background image

overview

4_

 overview 

IMPORTANT SAFETY INSTRUCTIONS

1. 

Read these instructions.

2. 

Keep these instructions.

3. 

Heed all warnings.

4. 

Follow all instructions.

5. 

Do not use this apparatus near water.

6. 

Clean the contaminated area on the product surface with a soft, dry cloth or a damp cloth.   
(Do not use a detergent or cosmetic products that contain alcohol, solvents or surfactants or oil constituents 
as they may deform or cause damage to the product.) 

7. 

Do not block any ventilation openings, Install in accordance with the manufacturer’s instructions.

8. 

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including 
amplifiers) that produce heat.

9. 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide 
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult 
an electrician for replacement of the obsolete outlet.

10. 

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and 
the point where they exit from the apparatus.

11. 

Only use attachments/ accessories specified by the manufacturer.

12. 

Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, 
or sold with the apparatus. When a cart is used, use caution when moving the cart/
apparatus combination to avoid injury from tip-over.

13. 

To prevent injury, this apparatus must be securely attached to the Wall/ceiling in 
accordance with the installation instructions..

14. 

Unplug this apparatus during lighting storms or when unused for long periods of time.

15. 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged 
in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into 
the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been 
dropped. 

16. 

This product is intended to be supplied by isolation power.

17. 

If you use excessive force when installing the product, the product may be damaged and malfunction. 
If you forcibly install the product using non-compliant tools, the product may be damaged.

18. 

Do not install the product in a place where chemical substances or oil mist exists or may be generated. As 
edible oils such as soybean oil may damage or warp the product, do not install the product in the kitchen or 
near the kitchen table. 
This may cause damage to the product.

19. 

When installing the product, be careful not to allow the surface of the product to be stained with chemical 
substance. 
Some chemical solvents such as cleaner or adhesives may cause serious damage to the product’s surface.

20. 

If you install/disassemble the product in a manner that has not been recommended, the production functions/
performance may not be guaranteed.

21. 

Do not install on a surface where it is exposed to direct sunlight, near heating equipment or heavy cold area.

22. 

Do not place this apparatus near conductive material.

23. 

Do not attempt to service this apparatus yourself.

24. 

Do not place a glass of water on the product.

25. 

Do not install near any magnetic sources.

26. 

Do not place heavy items on the product.

27. 

Please wear protective gloves when installing/removing the product. 
The high temperature of the product surface may cause a burn.

28. 

This device has been verified using STP cable. The use of appropriate GND grounding and STP cable 
is recommended to effectively protect your product and property from transient voltage, thunderstroke, 
communication interruption.

29. 

In particular installation environments, there might be interference in radio communications. 
When interference of electromagnetic waves occurs between the product and radio communication device, it 
is recommended to keep a certain distance between the two or change the direction of the receiving antenna..

30. 

An apparatus with CLASS   construction shall be connected to a MAINS socket outlet with a protective 
earthing connection.

31. 

Batteries(battery pack or batteries installed) shall not be exposed to excessive heat such as sunshine, fire or 
the like. The battery cannot be replaced.

32. 

Disconnect the main plug from the apparatus, if it’s defected. And please call a repair man in your location.

33. 

Select an installation site that can hold at least 5 times the product’s weight.

34. 

Stuck-in or peeled-off cables can cause damage to the product or a fire.

35. 

For safety purposes, keep anyone else away from the installation site. 
And put aside personal belongings from the site, just in case.

36. 

We do not guarantee the quality of third-party products (e.g. accessories) that you separately purchase.

37. 

When a PoE+ power supply is being used, high volume output may affect the system stability.

Rack Mount Instructions - The following or similar rack-mount instructions are included with 
the installation instructions:

A)  Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient 

temperature of the rack environment may be greater than room ambient. Therefore, consideration should be 
given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) 
specified by the manufacturer.

B)  Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required 

for safe operation of the equipment is not compromised.

C)  Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not 

achieved due to uneven mechanical loading.

D)  Circuit Overloading - Consideration should be given to the connection of the equipment to the supply 

circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. 
Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

E)  Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention 

should be given to supply connections other than direct connections to the branch circuit (e.g. use of power 
strips).

Содержание SPA-S1000

Страница 1: ...IP AUDIO SERVER User Manual SPA S1000...

Страница 2: ...n this document but no formal guarantee shall be provided Use of this document and the subsequent results shall be entirely on the user s own responsibility Hanwha Vision reserves the right to change...

Страница 3: ...mation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product CAUTI...

Страница 4: ...e it is exposed to direct sunlight near heating equipment or heavy cold area 22 Do not place this apparatus near conductive material 23 Do not attempt to service this apparatus yourself 24 Do not plac...

Страница 5: ...stem Configuration Diagram 7 Connecting To Power And A Network STARTING 8 8 Connecting to a PC 8 Access Product 11 Logging In ENVIRONMENT SETTINGS 12 12 System Management 14 Network Settings 15 Time S...

Страница 6: ...status LED Indicates power connection f AC Power code connection terminal Provides AC Power Name Function Description g Power switch Power on off switch h Power input terminal DC 24 V DC Power input t...

Страница 7: ...registered proper broadcasting cannot be performed The IP audio module can be used as an IP speaker when connected to an analog speaker with a permissible input of 10W or higher and an impedance of 8...

Страница 8: ...sswords Use Device Manager to set the initial password and IP address to use Registering using Device Manager If the product is connected to a network which includes a computer where the device manage...

Страница 9: ...are not used in the network audio product 4 Products with IP addresses must be logged in from the Credential menu to be queried as Login OK When you execute New Project Search authentication is cancel...

Страница 10: ...l IP address into the web browser s address bar 2 The admin account password must be registered when accessing the product for the first time When the Change Password window appears please enter a new...

Страница 11: ...menu of the web page Do not disconnect the power until the system initialization is complete after pressing the RESET button of the product or during product resetting 10 M To change the network setti...

Страница 12: ...Setting System Management 2 By clicking Destination Account from Password Change select the account you want to change and set the password 3 Click the Apply button after entering a new password in th...

Страница 13: ...ck Environment Setting System Management 2 Click Reset after checking the locked account on Account lock status The lock icon is changed to unlocked and the number of retries for the account is reset...

Страница 14: ...and you must register if you wish to use the product As the log information will be deleted when the product s system is initialized please download it in advance NETWORK SETTINGS You can change the n...

Страница 15: ...ime server 2 Click Apply to apply the set Time and Date information J If the product is used in a local network environment without an external Internet connection the time information may become inco...

Страница 16: ...bsite Korean English supported g Go to the Official Website If you click Hanwha the screen will move to the Hanwha Vision Official Website M The optimal monitor resolution is 1920x1080 OPERATION MODE...

Страница 17: ...volume If the volume is adjusted the speaker volume of the Button mode property is reflected on the same level When the volume is adjusted its output volume will be reflected at the same level in the...

Страница 18: ...f the source device to Multicast and broadcast the BGM sound source of the source device to the output device the Multicast IP address and the port information of the source device will be sent to the...

Страница 19: ...an select an output group among the set groups and duplicate selection is also possible The selected group will be displayed as highlighted When you select the Source Device and group and click the St...

Страница 20: ...reconfigure it The zone device which can be broadcast is displayed as Broadcasting count Total count If you manually control the speakers in Speaker Mode while running all the broadcasts with the Cont...

Страница 21: ...register all the other speakers as Speaker mode Control Mode When you run Start Broadcasting Stop Broadcasting from the Operate Button Mode you can control the zone devices with either the TCP or UDP...

Страница 22: ...irectly uploaded on PC you can select one from the Icon list 3 Once set click the Apply button 4 If you click the View Settings button the set value can be saved as a CSV file M You can use the Contro...

Страница 23: ...de broadcast will be kept since the priority of the microphone is higher Source Name Inputs or changes the name of a source Source Type Displayed as mic CH Name Displayed as 1 mic Transmission Method...

Страница 24: ...el Displayed as audio_output_1 2 Once set click the Apply button 3 If you click the View Settings button the set value can be saved as a CSV file M As the same speakers can be registered more than onc...

Страница 25: ...oadcast as per the scenario set in the All Event Preset List if an event such as the Event Preset of the button mode RM button of the microphone device or an external signal CP of the audio module occ...

Страница 26: ...e Output setting the Contact Closure Output signal will be active until the Contact Closure INPUT is Off If Contact Closure INPUT is Off while a sound source is being broadcasted the sound source will...

Страница 27: ...lume can be set Initial value 50 input value 0 100 The output volume is reflected only to Event Preset Delay Enter the delayed time before starting scenario broadcasting once the event has taken place...

Страница 28: ...schedules the holiday schedule will not be reflected even if you upload a downloaded file For holiday schedules use the download and upload functions of the Holiday menu Copy Schedules for each month...

Страница 29: ...pecific day the schedule is set on the specific date for every month or year If you specify a date range in Month or Year and select days of the week in Everyday the schedule is set only for those day...

Страница 30: ...t has an event priority set as 2000 in the Event Preset if the schedule time for a schedule that has a priority set as 1000 in the Annual Scheduler comes up the Event Preset broadcast will stop and th...

Страница 31: ...when the product s system is initialized please download it in advance M Every input field must be filled in Special characters cannot be input in the input field Locate a mouse pointer on a failure...

Страница 32: ...f where and how they can take these items for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product and i...

Страница 33: ......