HDP10000
Series
DC Regulated Power Supply
User Manual
2022.10
Страница 1: ...HDP10000 Series DC Regulated Power Supply User Manual 2022 10...
Страница 2: ...cts of Qingdao Hantek Electronics Co LTD and requires products patents or works of a third party the company shall be responsible for obtaining the consent and authorization of the third party The abo...
Страница 3: ...entilation requirements 2 1 4 Work environment 2 1 5 Maintenance and cleaning 3 1 6 Environmental considerations 4 2 Product features 5 3 Document overview 6 4 Quick start 7 4 1 General examination 7...
Страница 4: ...000 series user manual Copyright Qingdao Hantek Electronics Co LTD II 6 Performance indicators 15 7 Fault handling 17 8 Appendix 18 8 1 Appendix A accessories and options 18 8 2 Appendix B Warranty su...
Страница 5: ...connected to the ground before connecting the input or output end of the product Ensure that the product is properly grounded Check all terminal ratings To avoid fire or excessive current check all ra...
Страница 6: ...ymbols on the product warning Test ground 1 3 Ventilation requirements The instrument is forced cooled by a fan Ensure that the intake and exhaust areas are unblocked and free flowing air is available...
Страница 7: ...nlight for a long time when storing or placing the instrument Note To avoid damaging the instrument or accessories do not place it in fog liquid or solvent Cleaning Check the instrument and accessorie...
Страница 8: ...e product complies with the requirements of WEEE Directive 2002 96 EC Equipment recycling Producing this product requires the extraction and use of natural resources Some substances contained in the e...
Страница 9: ...voltage over current overload overheating short circuit protections Low noise temperature control fan quiet and durable On Off output control one button panel lock function to prevent misoperation Con...
Страница 10: ...hantek com Document format conventions Buttons Icons are used to represent front panel buttons For example represents the ON OFF button Document content conventions HDP10000 series DC regulated power...
Страница 11: ...keep it until the machine and accessories pass the electrical and mechanical tests Check the accessories Details of the accessories are provided in Appendix A Accessories and options at the back of th...
Страница 12: ...tor on the rear panel and the input voltage should be within the range allowed by the gear 10 Note Ensure that the AC voltage gear is consistent with the AC power input otherwise the power supply may...
Страница 13: ...ower cable provided in the accessories to connect the instrument to the properly grounded AC power supply To avoid electric shock ensure that the instrument has been properly grounded 4 Boot Press the...
Страница 14: ...lect the settings to be saved then hold down until the indicator lights is on The settings are then saved in M1 The operations for M2 to M4 are the same as those for M1 M5 M10 If you want to use M5 to...
Страница 15: ...18 W The USB quick charge automatically adjusts the output voltage and current according to the identified quick charge protocol Typical output voltages and currents are 5V 3 4A 9V 2 0A and 12V 1 5A...
Страница 16: ...djustment knob 12 Press the to enable OVP function The indicator light will be on Press again to disable OVP function The indicator light will be off Long press to enter the setting mode and use the v...
Страница 17: ...ht Qingdao Hantek Electronics Co LTD HDP10000 series user manual 13 4 4 2 Rear Panel Figure 4 4 Rear panel 1 Security lock hole 2 AC power socket 3 Fuse holder 4 Power on switch 5 115VAC 230VAC switch...
Страница 18: ...5 RS232 remote control Only HDP10000S supports RS232 remote control Use the RS232 serial port straight through cable for connection To use RS232 for remote control please log in to the following websi...
Страница 19: ...near regulation 0 01 5mV Setting resolution HDP135V6S 10mV HDP180V8S 10mV HDP1160V4S 0 100V 10mV 100 160V 100mV Setting precision 0 1 1 digits Read back resolution HDP135V6S 10mV HDP180V8S 10mV HDP116...
Страница 20: ...pported quick charging protocol DCP Apple Samsung and BC1 2 Qualcomm QC2 0 QC3 0 Huawei Quick Charge Protocol FCP Samsung Quick Charge Protocol AFC General features Remote interface RS232 Female conne...
Страница 21: ...output the output voltage is less than the set value and CC light is on It is the current protection The instrument will automatically switch to constant current working state At this time check the l...
Страница 22: ...Host model 210W 35V 6A AC input 115 230VAC HDP135V6 210W 35V 6A AC input 230VAC HDP135V6A 210W 35V 6A AC input 115VAC HDP135V6B 210W 35V 6A AC input 115 230VAC RS232 HDP135V6S 180W 80V 8A AC input 115...
Страница 23: ...d to be defective Hantek will repair or replace the product free of charge Please refer to Hantek s official website or product warranty card for details For full repair service or warranty instructio...
Страница 24: ...g U Gu No 780 Baoyuan Road High tech Zone Qingdao Shandong Province Switchboard 400 036 7077 E mail service hantek com Tel 0532 55678770 55678772 55678773 Postcode 266000 Website www hantek com Qingda...