Hans Turck DR15S-IOL8X2 Series Скачать руководство пользователя страница 1

Your Global Automation Partner

IO-Link Parameters – IO-Link Version 1.1

DR15S-…-IOL8X2…

Radar Distance Sensors

Содержание DR15S-IOL8X2 Series

Страница 1: ...Your Global Automation Partner IO Link Parameters IO Link Version 1 1 DR15S IOL8X2 Radar Distance Sensors ...

Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...

Страница 3: ...edback about these instructions 5 2 Notes on the Product 6 2 1 Product identification 6 2 2 Turck service 6 3 Software Supported IO Link Parameterization 7 4 IO Link Parameters 8 4 1 General parameters 8 4 2 Process input data 9 4 3 Standard parameters 10 4 4 Parameters 12 4 5 Events 20 5 Turck Subsidiaries Contact Information 21 ...

Страница 4: ...Contents 4 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...

Страница 5: ...tion of medium risk which may result in minor or moderate injury if not avoided NOTICE NOTICE indicates a situation which may lead to property damage if not avoided NOTE NOTE indicates tips recommendations and useful information on specific actions and facts The notes simplify your work and help you to avoid additional work u CALL TO ACTION This symbol denotes actions that the user must carry out ...

Страница 6: ...8 X2 Electrical version Indication X2 Multicolor LED Voltage range 8 17 33 VDC Output function 2UPN Switching outputs IOL IO Link H1 1 4 1 Electrical connection Connector Assignment 1 Standard assignment Number of contacts 4 4 contacts Connector type 1 Straight Connector type H1 M12 1 connector 2 2 Turck service Turck supports you with your projects from initial analysis to the commissioning of yo...

Страница 7: ...rameters via IO Link n via on request data objects e g close to the PLC via the IO Link function block n via tool based engineering using FDT DTM e g PACTware with the use of DTM or the IODD or the web demo and Turck configuration tool Device parameters on request data objects Device parameters are exchanged acyclically and on request of the IO Link master The IO Link master always sends a request...

Страница 8: ...imum cycle time 5 ms SIO supported True M Sequence Capability PREOPERATE TYPE_1_2 with 2 octets on request data OPERATE TYPE_2_V with 8 octets on request data ISDU supported Block Parameter True Data Storage True ProfileCharacteristic 0x000B SSP 3 2 includes 0x800B 0x4000 Identification and diagnosis includes 0x8000 0x8002 0x8003 0x8100 0x800D Switching signal channel 0x8001 Binary data channel 0x...

Страница 9: ...rocessDataIn 0 0001093613 The internal process data must be multiplied by a factor of 0 1 for the signal strength Signal strength in SignalStrength 0 1 Name Byte Bit Offset Bit length Subindex access supported Data Type Value Description Switching state of output 1 5 0 1 False Boolean False true False Off True On Switching state of output 2 5 1 1 False Boolean False true False Off True On Scaling ...

Страница 10: ... Command 2 0x2 0 0x0 True Write 0 0 8 UInteger 0 255 System command 65 Teach far point 66 Teach near point 126 Start blinking 127 Stop blinking 128 Device reset 129 Application reset 130 Restore fact ory settings 160 Reset largest distance value 161 Reset smallest distance value Parameter write Access Lock 12 0xC 1 0x1 False Read write 0 0 1 Boolean False true Device access locks Data Storage Lock...

Страница 11: ...0x15 0 0x0 True Read 0 0 128 String Device serial number Hardware Version 22 0x16 0 0x0 True Read 0 0 512 String Hardware revision Firmware Version 23 0x17 0 0x0 True Read 0 0 512 String Firmware revision Application Specific Tag 24 0x18 0 0x0 True Read write 0 0 256 String Any user generated content Error Count 32 0x20 0 0x0 True Read 0 0 16 UInteger Device Status 36 0x24 0 0x0 True Read 0 0 8 UI...

Страница 12: ... 0x1A 0 0x0 True Read write 0 0 256 String NaN NaN User text to describe location Teach channel 58 0x3A 0 0x0 True Read write 0 0 8 UInteger 0 2 0 Select the output to teach 0 Output 1 default 1 Output 1 2 Output 2 Teach state 59 0x3B 1 0x1 False Read 0 0 4 UInteger 0 15 0 0 Idle 1 SP1 success 2 SP2 success 3 SP12 success 4 Wait for command 5 Busy 6 7 Error 8 9 10 11 12 13 14 15 Far point SP1 TP1 ...

Страница 13: ...SP1 output 1 Measured value 10000 Value in meters Near SP2 60 0x3C 2 0x2 False Read write 4 0 32 Integer 3500 149500 37500 SP2 output 1 Measured value 10000 Value in meters Logic 61 0x3D 1 0x1 True Read write 0 0 8 UInteger 0 1 0 Switching logic output 1 0 Normally off high active 1 Normally on low active Switching mode 61 0x3D 2 0x2 True Read write 1 0 8 UInteger 0 3 3 0 Inactive 2 Window mode 3 ...

Страница 14: ...e 2 Window mode 3 Two point mode Hysteresis 63 0x3F 3 0x3 True Read write 2 0 16 UInteger 500 65535 500 Hysteresis output 1 Measured value 10000 Value in meters Operating hours 72 0x48 0 0x0 True Read 0 0 32 UInteger NaN NaN Total number of operating hours Output 1 73 0x49 1 0x1 True Read 0 0 32 UInteger NaN NaN 0 Total number of switching cycles Output 2 73 0x49 2 0x2 True Read 4 0 32 UInteger Na...

Страница 15: ...ching output Configuration 82 0x52 0 0x0 True Read write 0 0 8 UInteger 4 18 4 Configuration 4 Auto 4 20 mA 0 10 V 5 4 20 mA 6 0 20 mA 7 20 4 mA 8 20 0 mA 9 0 10 V 10 0 5 V 11 1 6 V 12 10 0 V 13 5 0 V 14 6 1 V 15 0 5 4 5 V 16 4 5 0 5 V 17 600 3000 Hz 18 3000 600 Hz Polarity 83 0x53 0 0x0 True Read write 0 0 8 UInteger 0 2 2 Select between PNP switching to UB or NPN switching to GND for output 1 0 ...

Страница 16: ...1 Switch active Error behavior 87 0x57 0 0x0 True Read write 0 0 8 UInteger 0 1 0 State of output switch 2 in case of error 0 Switch inactive 1 Switch active Polarity 95 0x5F 0 0x0 True Read write 0 0 8 UInteger 0 2 2 Select between PNP switching to UB or NPN switching to GND for out put 2 0 PNP output switching to UB 1 NPN output switching to GND 2 Auto detection Start point 98 0x62 1 0x1 False R...

Страница 17: ...er 0 600 0 On switching delay for output 1 Off Delay 121 0x79 0 0x0 True Read write 0 0 16 UInteger 0 600 0 Off switching delay for output 1 On Delay 122 0x7A 0 0x0 True Read write 0 0 16 UInteger 0 600 0 On switching delay for output 2 Off Delay 123 0x7B 0 0x0 True Read write 0 0 16 UInteger 0 600 0 Off switching delay for output 2 Signal strength indication 124 0x7C 0 0x0 True Read write 0 0 8 U...

Страница 18: ...6 UInteger 100 9999 100 Signals with lower amplitude are ignored Frontground suppression 148 0x94 0 0x0 True Read write 0 0 32 Integer 3000 149500 3000 Signals in front of this distance limit are ignored Background suppression 149 0x95 0 0x0 True Read write 0 0 32 Integer 4000 150500 150500 Signals behind this distance limit are ignored Signal amplification 167 0xA7 0 0x0 True Read write 0 0 8 UIn...

Страница 19: ...efault Description Upper Value Range 16512 0x 4080 2 0x2 False Read 4 0 32 Integer 150000 150000 Measured value 10000 Value in meters Unitcode for Meter 16512 0x 4080 3 0x3 False Read 8 0 16 UInteger 1010 1010 The process value is out put in meters Scaling Factor 16512 0x 4080 4 0x4 False Read 10 0 8 Integer 4 4 Measured value 10000 Value in meters ...

Страница 20: ...y voltage under run Check tolerance 25376 Error Parameter error Check data sheet and values 30480 Error Short circuit Check installation 35841 Warning Simulation active Check operational mode 35856 Warning Process variable range over run Process data uncertain 35872 Error Measurement range over run Check application 35888 Warning Process variable range under run Process data uncertain 36001 Error ...

Страница 21: ...3 MARNE LA VALLEE Cedex 4 www turckbanner fr Great Britain TURCK BANNER LIMITED Blenheim House Hurricane Way GB SS11 8YT Wickford Essex www turckbanner co uk India TURCK India Automation Pvt Ltd 401 403 Aurum Avenue Survey No 109 4 Near Cummins Complex Baner Balewadi Link Rd 411045 Pune Maharashtra www turck co in Italy TURCK BANNER S R L Via San Domenico 5 IT 20008 Bareggio MI www turckbanner it ...

Страница 22: ...CK RUS OOO 2 nd Pryadilnaya Street 1 105037 Moscow www turck ru Sweden Turck Sweden Office Fabriksstråket 9 433 76 Jonsered www turck se Singapore TURCK BANNER Singapore Pte Ltd 25 International Business Park 04 75 77 West Wing German Centre 609916 Singapore www turckbanner sg South Africa Turck Banner Pty Ltd Boeing Road East Bedfordview ZA 2007 Johannesburg www turckbanner co za Czech Republic T...

Страница 23: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100033485 2021 10 100033485 ...

Отзывы: