4
English
Assembly
(see page 35)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The drain valve must only be used as intended. It is
not allowed to attach other objects to the drain valve,
for example a semi-pedestal.
• The drain valve may only be installed in basins with
an overflow opening.
Technical Data
This mixer series-produced with EcoSmart
(flow limiter)
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Dimensions
(see page 38)
Flow diagram
(see page 37)
Spare parts
(see page 40)
XXX = Colors
000 = Chrome Plated
140 = Brushed Bronze
670 = Matt Black
700 = Matt White
Special accessories
(order as an extra)
• special tool #58085000 (see page 35)
• Installation putty (see page 36)
• flange Hot water limiter
(see page 40)
Cleaning
(see page 42)
Operation
(see page 37)
Hansgrohe recommends not to use as drinking water the
first half liter of water drawn in the morning or after a
prolonged period of non-use.
Test certificate
(see page )
Fault
Cause
Remedy
Insufficient water
- Aerator calcified, dirty
- Clean aerator, replace as necessary
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping in area of swivel
spout
- O-ring defective
- Exchange O-ring
Water escaping at the threaded base - connection hoses not completely
screwed into basic body
- Tighten connection hoses by hand
- O-ring at the connection hose
defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter