Assembly see page 31
Fault
Cause
Remedy
Insufficient water
-
Shower filter seal dirty
-
Clean filter seal between shower and hose
-
Non return valve hasn’t moved back
-
Exchange non return valves
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping
-
Cartridge defective
-
Exchange cartridge
Hot water temperature too low
-
Hot water limiter incorrectly set
-
Set hot water limiter
Instantaneous heater didn’t work
-
Flow limiter in handshower isn’t removed
-
Remove flow limiter
-
Filters are dirty
-
Clean the filter / exchange filter
-
Non return valve hasn’t moved back
-
Exchange non return valves
Test certificate
(see page 40)
Operation
(see page 35)
Cleaning
(see page 38) and enclosed brochure
Spare parts
(see page 40)
Flow diagram
(see page 36)
Hand shower
overhead shower
Dimensions
(see page 36)
Maintenance
(see page 33)
The non return valves must be checked regularly according to DIN
EN 1717 in accordance with national or regional regulations (at least
once a year).
Adjustment
(see page 34)
To adjust the hot water limiter on single lever mixers, please see page
34. No adjustment is necessary when using a continuous flow water
heater.
Do not use silicone containing acetic acid!
Symbol description
Technical Data
Operating pressure:
max.1 MPa
Recommended operating pressure:
0,15 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Centre distance:
150±12 mm
Connections G 1/2:
cold right - hot left
Thermal disinfection:
max. 70°C / 4 min
anti-pollution function
The product is exclusively designed for drinking water!
6
Safety Notes
6
Gloves should be worn during installation to prevent crushing and cutting
injuries.
6
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
6
Children as well as adults with physical, mental and/or sensoric impairments
must not use this shower system without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this shower system.
6
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
6
The product may not be used as a holding handle. A separate handle must be
installed.
6
The shower system may only be used for bathing, hygienic and body cleansing
purposes.
6
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Important! The fitting must be installed, flushed and tested after the valid norms.
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The installation dimensions stated in this installation instructions are ideal for peo-
ple of approximately 1800 mm in body height. The dimensions can be altered if
required. In this case you will have to attend to the minimum height of 2320 mm
from shower tray floor, and alter all the required measurements as necessary.
• Where the contractor mounts the product, he should ensure that the entire area of
the wall to which the mounting plate is to be fitted, is flat (no projecting joints or
tiles sticking out), that the structure of the wall is suitable for the installation of the
product and has no weak points. The enclosed screws and dowels are only suita-
ble for concrete. For another wall constructions the manufacturer’s indications of
the dowel manufacturer have to be taken into account.
• The filter insert (A) must be used to ensure the standard flow rate and to protect
the hand shower against incoming dirt by pipework. Do you want a larger water
flow rate, then you must use the filter packing (B) instead of the filter insert (A).
Incoming dirt leads to defects or/and can damage parts of the hand shower;
such caused faults voids all liability and guarantee claims.
English
4
Содержание Showerpipe EHM EcoSmart 27191000
Страница 31: ...31 Silicone 1 2 min 32 mm 3a 3b 98681000 max 37 mm max 5 mm 4 5 6 2 1 2 1 2 1...
Страница 32: ...32 SW 8 mm 7 12b 14 8 12a 13 3 1 2 1 2 10 11 9 SW 30 mm 17 Nm 98681000 SW 8 mm...
Страница 33: ...33 SW 3 mm 15 17 16 18 SW 8 mm 2 1 3 1 2 3 A B...
Страница 34: ...34 60 C 10 C 0 3 MPa 0 3 0 3 2 1 3 4 5 6 7...
Страница 36: ...36 Showerpipe EHM EcoSmart 27191000 Showerpipe EHM EcoSmart 27191000...
Страница 37: ...37 Showerpipe EHM 27193000 Showerpipe EHM 27193000...
Страница 38: ...38 1 2 1 4 3 2 1 min 1 4 2 3 SW 5 mm AIR SW 4 mm ECO SW 5 mm AIR SW 4 mm ECO 2 Nm 1 2 2 1...
Страница 39: ...39...