4
English
Assembly
(see page 33)
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The product may only be used for bathing, hygienic and body cleaning
purposes.
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influence
of alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the fact that a change of
installation height will also change the minimum height, and that the altered
mounting dimensions must be taken into consideration.
• During installation of the product by qualified trained personnel, make sure that
the entire fastening surface is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the product and has no weak
points.
• The mesh washer must be insert to protect the shower against incoming dirt by
pipework. Incoming dirt leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and guarantee claims.
• The premounted dirt collection screen must be used to prevent dirt from entering
through the pipes. Dirt entering can affect the function and/or lead to damage to
the functional components of the fitting. Hansgrohe will not be held liable for any
resulting damage.
• The product is not designed to be used with steam baths!
Special information for UK
If installing this product with a pump, please be aware that it has to have negative
head switching. This product will not function with a positive head pump.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Centre distance:
150±12 mm
Connections G 1/2:
cold right - hot left
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Safety Function
(see page 36)
The desired maximum temperature for example max. 42°C can be pre-set thanks to
the safety function.
Adjustment
(see page 35)
After the installation, the output temperature of the thermostat must be checked. A
correction is necessary if the temperature measured at the output differs from the
temperature set on the thermostat.
Dimensions
(see page 37)
Flow diagram
(see page 37)
free flow
Hand shower
Overhead shower
Spare parts
(see page 42)
Special accessories
(order as an extra)
tile-matching-disk Chrome Plated #93146000 (see page 42)
Cleaning
(see page 40)
Operation
(see page 38)
To empty the overhead shower after use, hold it in a slightly inclined position.
Test certificate
(see page 44)
Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Regulator filter dirty
- Clean filter in front of the mixer and on the MTC-ther-
mo cartridge
- Shower filter seal dirty
- filter insert shower dirty
- Clean filter seal between shower and hose
- Clean filter insert between shower and hose
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
- Backflow preventers dirty or leaking
- Clean backflow preventers, exchange if necessary
Spout temperature does not correspond with tempera-
ture set
- Thermostat has not been adjusted
- Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to 42 °C to 60 °C
Temperature regulation not possible
- thermo cartridge calcified
- Exchange thermo cartridge
Instantaneous heater didn't work with thermostat
- Filters are dirty
- Clean the filter / exchange filter
- check valve hasn't moved back
- Exchange check valves
- Flow limiter in handshower isn’t removed
- Remove flow limiter
Shower drips continuously
- Dirt or sedimentation on valve seat, shut-off unit
damaged
- Exchange shut-off unit
Содержание Showerpipe E 300 1jet EcoSmart 350 ST...
Страница 29: ...29 33 1800 1 0 5 0 1 1 6 PSI 147 10 1 60 C 12 150 2 G 1 C 07 4 36 42 35 37 37 42 42 93146000 40 38 44 60 42...
Страница 35: ...35 1 2 3 40...
Страница 36: ...36 1 2 SW 3 mm SW 3 mm 1 Nm for example 42 C z B 42 C 40 1 2 3 4 5 6 7 8 9 10 11...
Страница 41: ...41 25 mm 40 0 2 5 3 6 8 7 10 1 4 9 SW 28 mm SW 28 mm 5 Nm SW 1 5 mm SW 1 5 mm 1 Nm SW 4 mm 2 Nm 1 min...
Страница 43: ...43...