Hans Grohe Shower Select 15765007 Скачать руководство пользователя страница 3

3

English

Assembly 

(see page 6)

 

Safety Notes

 

Gloves should be worn during installation to prevent crushing and cutting 

injuries.

 

The product may only be used for bathing, hygienic and body cleaning 

purposes.

 

Children as well as adults with physical, mental and/or sensoric impairments 

must not use this product without proper supervision. Persons under the 

influence of alcohol or drugs are prohibited from using this product.

 

The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport damages. After it has been 

installed, no transport or surface damage will be honoured.

• The pipes and the fixture must be installed, flushed and tested as per the 

applicable standards.

• The plumbing codes applicable in the respective countries must be observed.

Technical Data

Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,1 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar = 147 PSI) 

Hot water temperature: 

max. 60°C 

Thermal disinfection: 

70°C / 4 min

• Safety against backflow
• The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!

Adjustment 

(see page 9)

After the installation, the output temperature of the thermostat must be checked. A 

correction is necessary if the temperature measured at the output differs from the 

temperature set on the thermostat.

Safety Function 

(see page 10)

The desired maximum temperature for example max. 42º C can be pre-set thanks 

to the safety function.

Installation example 

(see page 4)

Maintenance 

(see page 10)

• The check valves must be checked regularly according to EN 806-5 in 

accordance with national or regional regulations (at least once a year).

• To guarantee the smooth running of the thermostat, it is necessary from time to 

time to turn the thermostat from total hot to total cold.

Dimensions 

(see page 12)

Flow diagram 

(see page 12)

  Outlet 1 free flow

  Shower outlet

Spare parts 

(see page 14)

Special accessories 

(see page 14)

 

(order as an extra)

Cleaning 

(see page 13)

Operation 

(see page 12)

Minor leaking may occur briefly during initial commissioning and interruption/

restart of the water supply.

i

+

Fault

Cause

Remedy

Insufficient water

- Supply pressure inadequate

- Check water pressure (If a pump has been installed 

check to see if the pump is working).

- Regulator filter dirty

- Clean filter in front of the mixer and on the MTC-ther-

mo cartridge

- Shower filter seal dirty

- Clean filter seal between shower and hose

Crossflow, hot water being forced into cold water 

pipe, or vice versa, when mixer is closed

- Backflow preventers dirty or leaking

- Clean backflow preventers, exchange if necessary

Spout temperature does not correspond with 

temperature set

- Thermostat has not been adjusted

- Adjust thermostat

- Hot water temperature too low

- Increase hot water temperature to 42 ºC to 60 ºC

Temperature regulation not possible

- Temperature regulator dirty or calcified

- Clean temperature regulator, exchange if necessary

Safety stop button not operating

- Spring defective
- Button calcified

- Clean spring and/or button, exchange if necessary

Valve stiff

- Select stop valve DN9 damaged

- Exchange Select stop valve

Shower or spout dripping

- Select stop valve DN9 damaged

- Exchange Select stop valve

Pushbutton cannot be actuated or is without function

- Safety guard of isolating valve has not been 

removed

- Remove safety guard from isolating valve

Pushbutton is jammed or stiff

- Seal needs greasing

- Grease the seal

Pushbutton does not snap in

- Select Adapter incorrectly trimmed

- Trim and mount Select Adapter according to Fig. 

6 (see page 6)

- First, fully press the pushbutton down into the rosette; 

then, mount the rosette

Содержание Shower Select 15765007

Страница 1: ...ZH 2 EN Instructions for use Assembly instructions 3 Shower Select 15765007 40 C...

Страница 2: ...2 6 1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 60 C 70 C 4 9 10 42 4 10 EN 806 5 12 12 1 14 14 13 12 i 42 C 60 C Select DN9 Select Select DN9 Select 6 6...

Страница 3: ...mooth running of the thermostat it is necessary from time to time to turn the thermostat from total hot to total cold Dimensions see page 12 Flow diagram see page 12 Outlet 1 free flow Shower outlet S...

Страница 4: ...20 3 4 DN 15 1 2 DN 20 3 4 bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0...

Страница 5: ...5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec 77 111 1100 900 650 550 DN 20 3 4 DN 20 3 4 DN...

Страница 6: ...mm 01800187 2 3 1 SW 4 mm 5 Nm SW 10 mm Armaturenfett Grease A r m a t u r e n f e t t G r e a s e 1 0 mm 0 mm SW 5 mm 2 A r m a t u r e n f e t t G r e a s e 1 SW 10 mm 1 2 2 Silicone 1 2 3 4 5 6 7 8...

Страница 7: ...7 21 16 max 5 SW 4 mm SW 4 mm 5 Nm 7 mm 0 X 2 1 X 2 mm 2 1 X 11 1 2 mm X 0 1 Nm 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27...

Страница 8: ...8 60 mm 6 mm 0 1 Nm 1 2 3 SW 10 mm 6 Nm 40 C 40 C 40 C 40 C 40 C 2 1 3 1 Nm 40 C 1 2 0 mm A 41 0 mm SW 8 mm 4 Nm Silicone 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42...

Страница 9: ...9 40 C A r m a tu r e n fe tt G r e a s e 40 C 40 C 40 C 40 C 2 1 2 1 40 C 1 2 40 C 40 C B C A 37 40 C 1 2 3 43 44 45 46...

Страница 10: ...10 40 C 40 C SW 3 mm 1 Nm 40 C 40 C 40 C 2 2 1 1 40 C 1 2 40 C 40 C SW 3 mm 40 C 2 1 z B 42 C for example 42 C 40 C SW 8 mm 40 C 40 C 40 C 2 1 1 2 3 4 5 6 7 8 9 1 2 3 4...

Страница 11: ...0 C 40 C 40 C SW 4 mm 40 C 2 1 SW 10 mm 2 1 3 SW 4 mm 5 Nm SW 10 mm 6 Nm SW 27 mm SW 27 mm 8 Nm 0 1 Nm 40 C 40 C SW 8 mm 4 Nm 1 Nm 2 1 40 C 1 2 40 C 40 C 1 2 1 2 5 6 7 8 9 10 12 13 14 15 16 17 18 19 2...

Страница 12: ...0 12 15 5 54 82 4 4 4 6 5 7 188 167 15 5 7 7 94 1 40 C 1 1 bar 0 6 12 18 24 30 36 42 48 MPa 0 0 2 0 4 0 6 0 8 Q l min Q l sec 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20...

Страница 13: ...could enter openings and gaps in the Hansgrohe products and cause damage After cleaning rinse thoroughly with clean water to remove any cleaner residue The use of steam cleaners is not permitted The...

Страница 14: ...000 10x1 5 98282007 98146000 25x1 5 92146000 25x2 5 92298000 92299000 92218000 92218000 95531000 96454000 M5x55 95521000 1 98133000 16x2 98385000 11x1 5 13583000 92540000 13601000 22 mm 92219000 92696...

Страница 15: ...15...

Страница 16: ...Hansgrohe Auestra e 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 05 2022 9 02524 51...

Отзывы: