Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using
this product.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
Safety against backflow
The product is exclusively designed for drinking water!
English
Test certificate
(see page 76)
Flow diagram
(see page 66)
Rate of flow by 0,3 MPa:
Maintenance
(see page 64)
• The mixer is equipped with check valves.
The check valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
• To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
Adjustment
(see page )62
After the installation, the output temperature
of the fitting must be tested and set to the
temperate desired by the customer.
Spare parts
(see page 67)
Operation
(see page 76)
Do not use silicone containing acetic acid!
Symbol description
Dimensions
(see page 66)
Cleaning
see enclosed brochure
Safety Function
(see page 62)
The desired maximum temperature for exam-
ple max. 42º C can be pre-set thanks to the
safety function.
6
Содержание Metris 31570000
Страница 24: ...1 MPa 0 1 0 5 MPa 1 6 MPa 80 C 65 C 70 C 4 76 66 0 3 MPa 64 DIN EN 1717 62 67 76 66 62 42 24...
Страница 25: ...42 C 65 C 180 180 60 25...
Страница 26: ...1 0 1 0 5 1 6 80 C 65 C 70 C 4 76 66 0 3 64 DIN EN 1717 62 67 76 66 Safety Function 62 Safety Function 42 C 26...
Страница 27: ...42 65 180 60 27...
Страница 43: ...42 C 65 C 180 180 60 43...
Страница 55: ...42 C 65 C 180 180 60 55...
Страница 58: ...42 65 180 180 60 58...
Страница 59: ...1 0 5 0 1 1 6 80 C 65 C 4 70 C 76 66 0 3 64 DIN EN 1717 DIN 1988 62 67 76 66 62 42 59...
Страница 60: ...60 Montage X 1 2 mm 2 1 2 1 3 4 5 X 11 01800180 2 3 1 2...
Страница 61: ...61 Montage 6 7 8 4 SW 3 mm 4 Nm 0 1 Nm 2 3 Nr 10476220 Armaturenfett Grease 1...
Страница 62: ...62 Safety Function Justierung 2 1 3 1 1 2 SW 3 mm 2...
Страница 63: ...63 Safety Function z B 42 C for example 42 C 2 1 1 2 3 4 5 6 7 8 SW 3 mm 4 Nm...
Страница 64: ...64 Wartung 1 2 2 3 4 5 SW 24 mm SW 4 mm 1 1 2 6 A...
Страница 65: ...65 Wartung 7 8 9 10 11 SW 24 mm 15 Nm 1 2 1 2 SW 4 mm 5 Nm 0 1 Nm...
Страница 66: ...66 Ma e Durchflussdiagramm Ma e Durchflussdiagramm Ecostat S 15711000 65 93 55 55 150 15 Metris 31570000...
Страница 74: ...74...
Страница 75: ...75...