Assembly see page 31
English
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• 71400000: The diverter (type HC) installed in the
bath mixer is designed as an anti-retraction device. For
this reason, the lower edge of the diverter must be at
least 250 mm above the highest possible dirty water
level.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
Fault
Cause
Remedy
Insufficient water
-
check valve hasn't moved back
-
Exchange check valves
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping
-
Cartridge defective
-
Exchange cartridge
Hot water temperature too low
-
Hot water limiter incorrectly set
-
Set hot water limiter
Instantaneous heater didn’t work
-
Flow limiter in handshower isn’t
removed
-
Remove flow limiter
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
-
check valve hasn't moved back
-
Exchange check valves
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 5)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Maintenance
(see page 40)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Cleaning
see enclosed brochure.
Dimensions
(see page 34)
Flow diagram
(see page 34)
Operation
(see page 38)
Spare parts
(see page 36)
Safety against backflow
The product is exclusively designed for drinking water!
4
Test certificate
(see page 40)